Effect of assistive devices on the precision of digital implant impressions for fully edentulous maxilla: An in vivo study
Journal of Prosthodontic Research · 2025 · 69 (4) · 526-532
DOI: 10.2186/jpr.jpr_d_24_00261 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Prosthodontic Research, 2025. Verfasst von Keisuke Ashida und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Prosthodontics, Showa University School of Dentistry, Tokyo, Japan. Hauptthemen laut MEDLINE: Maxilla, Dental Impression Technique, Jaw, Edentulous, Dental Implants. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 26 Literaturangaben.
Abstract (Originalsprache)
PURPOSE: This study examined the effect of assistive device use on the precision of digital impressions for multiple implants placed in a fully edentulous maxilla in vivo. METHODS: A total of eight participants with fully edentulous maxillae and four implants at position #15, #12, #22, and #25 were included in the study. The assistive device was made using CAD/CAM technology. Digital impressions were obtained using an intraoral scanner with (AD+) and without (AD-) the assistive device that attached to the scan bodies. Each participant underwent five digital and conventional impressions (verification casts (VC)). Dimensional deviations for each impression method were measured using the least-squares best-fit method to assess precision. Statistical analysis was performed using one-way analysis of variance (ANOVA) with Tukey's post-hoc adjustments for multiple comparisons. RESULTS: The dimensional deviations were as follows: AD- (37.56 ± 7.43 µm), AD+ (16.23 ± 2.56 µm), and VC (26.48 ± 5.13 µm). One-way ANOVA revealed significant differences between the groups (F = 31.04, P < 0.0001), which remained after Tukey adjustment (P < 0.01). The AD+ group exhibited the highest precision, while the AD- group had the lowest. CONCLUSIONS: For implants placed in a fully edentulous maxilla in vivo, digital impressions with assistive devices demonstrated superior precision compared with those obtained without assistive devices or conventional impressions obtained with an implant indexing device.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Prosthodontics, Showa University School of Dentistry, Tokyo, Japan.
Zitieren
APA
Ashida, K., Sanda, M., Tanaka, S., & Baba, K. (2025). Effect of assistive devices on the precision of digital implant impressions for fully edentulous maxilla: An in vivo study. Journal of Prosthodontic Research, 69(4), 526-532. https://doi.org/10.2186/jpr.jpr_d_24_00261
Vancouver
Ashida K, Sanda M, Tanaka S, Baba K. Effect of assistive devices on the precision of digital implant impressions for fully edentulous maxilla: An in vivo study. Journal of Prosthodontic Research. 2025;69(4):526-532. doi:10.2186/jpr.jpr_d_24_00261
BibTeX
@article{Ashida2025,
author = {Ashida, Keisuke and Sanda, Minoru and Tanaka, Shinpei and Baba, Kazuyoshi},
title = {Effect of assistive devices on the precision of digital implant impressions for fully edentulous maxilla: An in vivo study},
journal = {Journal of Prosthodontic Research},
year = {2025},
volume = {69},
number = {4},
pages = {526--532},
doi = {10.2186/jpr.jpr_d_24_00261}
}