EUVIMEDEUVIMED entdecken
Vergleichsstudie

Accuracy of complete‐arch digital implant impression with intraoral optical scanning and stereophotogrammetry: An in vivo prospective comparative study

Alessandro Pozzi iD, Paolo Carosi iD, German O Gallucci iD, Katalin Nagy, Alessandra Nardi, Lorenzo Arcuri

Clinical Oral Implants Research · 2023-10 · 34 (10) · 1106-1117

DOI: 10.1111/clr.14141 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Clinical Oral Implants Research, online erschienen am 24.07.2023. Verfasst von Alessandro Pozzi und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Clinical Sciences and Translational Medicine, School of Dentistry, University of Tor Vergata, Rome, Italy. Hauptthemen laut MEDLINE: Photogrammetry, Dental Impression Technique, Dental Prosthesis, Implant-Supported, Dental Implants. Die Arbeit wurde bisher 61-mal zitiert (Crossref) und nennt 46 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

To assess accuracy of intraoral optical scanning (IOS) and stereophotogrammetry (SPG), complete‐arch digital implant impressions in vivo. Materials and Methods Consecutive patients needing implant‐supported screw‐retained zirconia complete‐arch fixed‐dental prostheses (ISZ‐FDP) were recruited. For each patient, three impressions were taken: IOS, SPG (tests), and open‐tray plaster (reference). Linear (Δ X , Δ Y , and Δ Z ), three‐dimensional (ΔEUC), and angular deviations (ΔANGLE) were evaluated and stratified according to scanning technology for each implant. Potential effects of impression device (IOS and SPG), arch (maxilla and mandible), and implant number (4 and 6) were evaluated through multivariable analysis. Significance level was set at .05.

Results

A total of 11 complete arches (5 maxillae, 6 mandibles) in 11 patients were rehabilitated with ISZ‐FDPs supported by 4 ( n = 8) and 6 implants ( n = 3). A total of 50 implants and 100 implant positions were captured by two investigated devices and compared to respective reference (mean ΔEUC IOS 137.2, SPG 87.6 μm; mean ΔANGLE 0.79, 0.38°). Differences between measurements (SPG‐IOS) were computed for each implant, with negative values indicating better SPG accuracy. Significant mean ΔEUC difference of −49.60 μm ( p = .0143; SD 138.15) and mean ΔANGLE difference of −0.40° ( p < .0001; SD 0.65) were observed in favor of SPG. Multivariable analysis showed significant effect on ΔEUC ( p = .0162) and ΔANGLE ( p = .0001) only for impression devices, with SPG performing better.

Conclusions

SPG experienced significantly higher linear and angular accuracy. No effect of type of arch or implant number was detected. Higher extreme deviations were experienced for IOS. SPG can be feasible for complete‐arch digital impressions with caution, and rigid prototype try‐in is recommended before screw‐retained prosthesis manufacturing.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

PhotogrammetryDental Impression TechniqueDental Prosthesis, Implant-SupportedDental ImplantsHumansProspective StudiesMaleFemaleMiddle AgedComputer-Aided DesignAgedAdultDental Prosthesis DesignImaging, Three-Dimensional

Stichwörter der Autor:innen

complete archdental implantdigital impressionintraoral scannerstereophotogrammetry

Substanzen

Dental Implants

Autor:innen und Institutionen

  • Department of Clinical Sciences and Translational Medicine, School of Dentistry, University of Tor Vergata, Rome, Italy.
  • Departement of Restorative Sciences, Dental College of Georgia, Augusta University, Augusta, USA.
  • Department of Chemical Science and Technologies, PhD in Materials for Health, Environment and Energy - Dentistry, University of Rome Tor Vergata, Rome, Italy.
  • Department of Restorative Dentistry and Biomaterials Sciences, Harvard School of Dental Medicine, Boston, Massachusetts, USA.
  • Department of Oral Surgery, Faculty of Dentistry, University of Szeged Tisza L. Krt, Szeged, Hungary.
  • Department of Mathematics, University of Rome Tor Vergata, Rome, Italy.

ORCID-Profile: Alessandro Pozzi, Paolo Carosi, German O Gallucci

Zitieren

APA

Pozzi, A., Carosi, P., Gallucci, G. O., Nagy, K., Nardi, A., & Arcuri, L. (2023). Accuracy of complete‐arch digital implant impression with intraoral optical scanning and stereophotogrammetry: An in vivo prospective comparative study. Clinical Oral Implants Research, 34(10), 1106-1117. https://doi.org/10.1111/clr.14141

Vancouver

Pozzi A, Carosi P, Gallucci GO, Nagy K, Nardi A, Arcuri L. Accuracy of complete‐arch digital implant impression with intraoral optical scanning and stereophotogrammetry: An in vivo prospective comparative study. Clinical Oral Implants Research. 2023;34(10):1106-1117. doi:10.1111/clr.14141

BibTeX
@article{Pozzi2023,
  author = {Pozzi, Alessandro and Carosi, Paolo and Gallucci, German O and Nagy, Katalin and Nardi, Alessandra and Arcuri, Lorenzo},
  title = {Accuracy of complete‐arch digital implant impression with intraoral optical scanning and stereophotogrammetry: An in vivo prospective comparative study},
  journal = {Clinical Oral Implants Research},
  year = {2023},
  volume = {34},
  number = {10},
  pages = {1106--1117},
  doi = {10.1111/clr.14141}
}
Kostenlos starten →