EUVIMEDEUVIMED entdecken
Crossref

Characteristics of In Vivo Lesion Formation With a Temperature-Controlled Diamond-Tip Radiofrequency Ablation Catheter in the Ventricle: A Preclinical Model

Tatsuhiko Hirao iD, Maryam E Rettmann iD, Megan M Schmidt iD, Omar Z Yasin iD, Gurukripa N Kowlgi iD, Naoto Otsuka iD, Taro Koya iD, Laura K Newman iD, Douglas L Packer iD, Konstantinos C Siontis iD

Circulation: Arrhythmia and Electrophysiology · 2025

DOI: 10.1161/circep.124.013120 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Circulation: Arrhythmia and Electrophysiology, 2025. Verfasst von Tatsuhiko Hirao und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiovascular Medicine, Mayo Clinic, Rochester, MN (T.H., M.E.R., O.Z.Y., G.N.K., N.O., T.K., L.K.N., D.L.P., K.C.S.). Hauptthemen laut MEDLINE: Catheter Ablation, Cardiac Catheters, Heart Ventricles, Myocardium. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 21 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Power-controlled radiofrequency ablation with irrigated-tip catheters has been the norm for ventricular ablation for almost 2 decades. New catheter technology has recently integrated more accurate tissue temperature sensing enabling temperature-controlled irrigated ablation. We aimed to investigate the in vivo ablation parameters and lesion formation characteristics in ventricular myocardium using a novel temperature-controlled radiofrequency catheter. METHODS: Twenty canines were divided into 3 groups: 4 noninfarcted, acute (phase I); 8 noninfarcted, chronic (phase II); and 8 infarcted, chronic (phase III). Lesions were delivered with a temperature-controlled radiofrequency system utilizing a chemical vapor deposit diamond for efficient thermal diffusivity. In phase I, 17 ablation settings were tested (temperature set points, 50/60/70 °C; ablation duration, 15/30/60/90/120 s; and power limit, 30/50 W). Four and one of these sets of parameters were further tested in phases II and III, respectively. Lesions were assessed by ex vivo contrast-enhanced magnetic resonance imaging and gross pathology 5 weeks after ablation in phases II/III. RESULTS: Across all phases, 111 ablation lesions were delivered. Ablation with the power limit of 50 W, the temperature set point of 60 °C, and the duration of 60 s produced significantly larger and deeper lesions (mean, 569.2 mm 3 ; mean maximal depth, 9.8 mm) compared with 50 W/60 °C/30 s (mean, 340.4 mm 3 ; mean maximal depth, 8.3 mm) and 50 W/50 °C/60 s (mean, 227 mm 3 ; mean maximal depth, 6.9 mm), with P

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Catheter AblationCardiac CathetersHeart VentriclesMyocardiumDiamondMyocardial InfarctionAnimalsDogsEquipment DesignDisease Models, AnimalTemperatureMagnetic Resonance ImagingTime FactorsTherapeutic Irrigation

Stichwörter der Autor:innen

arrhythmia, cardiaccathetersmyocardium

Substanzen

Diamond

Autor:innen und Institutionen

  • Department of Cardiovascular Medicine, Mayo Clinic, Rochester, MN (T.H., M.E.R., O.Z.Y., G.N.K., N.O., T.K., L.K.N., D.L.P., K.C.S.).
  • Medtronic, Inc, Minneapolis, MN (M.M.S.).
  • Now with Department of Cadiology, Intermountain Medical Center, Murray, UT (D.L.P.).

ORCID-Profile: Tatsuhiko Hirao, Maryam E Rettmann, Megan M Schmidt, Omar Z Yasin, Gurukripa N Kowlgi, Naoto Otsuka, Taro Koya, Laura K Newman, Douglas L Packer, Konstantinos C Siontis

Zitieren

APA

Hirao, T., Rettmann, M. E., Schmidt, M. M., Yasin, O. Z., Kowlgi, G. N., Otsuka, N., Koya, T., Newman, L. K., Packer, D. L., & Siontis, K. C. (2025). Characteristics of In Vivo Lesion Formation With a Temperature-Controlled Diamond-Tip Radiofrequency Ablation Catheter in the Ventricle: A Preclinical Model. Circulation: Arrhythmia and Electrophysiology. https://doi.org/10.1161/circep.124.013120

Vancouver

Hirao T, Rettmann ME, Schmidt MM, Yasin OZ, Kowlgi GN, Otsuka N, et al. Characteristics of In Vivo Lesion Formation With a Temperature-Controlled Diamond-Tip Radiofrequency Ablation Catheter in the Ventricle: A Preclinical Model. Circulation: Arrhythmia and Electrophysiology. 2025. doi:10.1161/circep.124.013120

BibTeX
@article{Hirao2025,
  author = {Hirao, Tatsuhiko and Rettmann, Maryam E and Schmidt, Megan M and Yasin, Omar Z and Kowlgi, Gurukripa N and Otsuka, Naoto and Koya, Taro and Newman, Laura K and Packer, Douglas L and Siontis, Konstantinos C},
  title = {Characteristics of In Vivo Lesion Formation With a Temperature-Controlled Diamond-Tip Radiofrequency Ablation Catheter in the Ventricle: A Preclinical Model},
  journal = {Circulation: Arrhythmia and Electrophysiology},
  year = {2025},
  doi = {10.1161/circep.124.013120}
}
Kostenlos starten →