Factors Influencing Lesion Titration in a Monopolar Pulsed-Field Ablation Point Catheter: A Preclinical Study
Circulation: Arrhythmia and Electrophysiology · 2026
DOI: 10.1161/circep.125.014157 ↗Kurz gefasst
Fachartikel in der Zeitschrift Circulation: Arrhythmia and Electrophysiology, 2026. Verfasst von Arwa Younis und 18 weiteren Autor:innen. Beteiligte Einrichtung: Cardiac Electrophysiology Section, Department of Cardiovascular Medicine, Cleveland Clinic, OH (A.Y., J.D., I.L., P.S., A.A.H., M.M., T.L.T., C.T., H…. Hauptthemen laut MEDLINE: Catheter Ablation, Cardiac Catheters, Heart Ventricles. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 16 Literaturangaben.
Abstract (Originalsprache)
BACKGROUND: Despite the rise of pulsed-field ablation (PFA), predicting and titrating lesion geometry remains challenging. This study aimed to find modifiable parameters that can accurately and repeatedly predict focal PFA lesions across a range of dimensions and to develop a model to predict lesion geometry. METHODS: An in vivo study was performed in 9 swine using an investigational dual-energy contact-force focal catheter with local impedance. Ablations were performed endocardially in the right and left ventricles using settings specifically selected to provide a wide range of lesion dimensions. Predefined PFA applications (1, 2, or 4) were delivered while maintaining different contact-force values (5–45 g). Four different voltages were used (1.0, 1.4, 2.0, and 2.2 kV). Following a 1-week survival period, the animals were euthanized for histopathologic examination. RESULTS: In the study characterization data set, a total of 78 PFA lesions were analyzed. Lesion depth ranged from 1.4 mm to 12.3 mm, while lesion width ranged from 3.3 mm to 21.2 mm. All 3 tested parameters—contact force, number of applications, and voltage—demonstrated a positive linear correlation with lesion depth ( P
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Cardiac Electrophysiology Section, Department of Cardiovascular Medicine, Cleveland Clinic, OH (A.Y., J.D., I.L., P.S., A.A.H., M.M., T.L.T., C.T., H.N., M.F., W.I.S., M.K., O.M.W.).
- Electrophysiology Department, Boston Scientific Corporation, Marlborough, MA (S.B., L.L., S.H., R.K., M.M.R., K.G.).
ORCID-Profile: Arwa Younis, Joe Demian, Ioan Liuba, Samuel Hinds, Pasquale Santangeli, Ayman A Hussein, Mohamad Mdaihly, Tyler L Taigen, Chadi Tabaja, Hiroshi Nakagawa, Medhat Farwati, Walid I Saliba, Mohamed Kanj, Kara Garrott, Oussama M Wazni
Zitieren
APA
Younis, A., Demian, J., Bifulco, S., Lehn, L., Liuba, I., Hinds, S., Santangeli, P., Hussein, A. A., Mdaihly, M., Taigen, T. L., Tabaja, C., Nakagawa, H., Farwati, M., Kleve, R., Mora Ramirez, M., Saliba, W. I., Kanj, M., Garrott, K., & Wazni, O. M. (2026). Factors Influencing Lesion Titration in a Monopolar Pulsed-Field Ablation Point Catheter: A Preclinical Study. Circulation: Arrhythmia and Electrophysiology. https://doi.org/10.1161/circep.125.014157
Vancouver
Younis A, Demian J, Bifulco S, Lehn L, Liuba I, Hinds S, et al. Factors Influencing Lesion Titration in a Monopolar Pulsed-Field Ablation Point Catheter: A Preclinical Study. Circulation: Arrhythmia and Electrophysiology. 2026. doi:10.1161/circep.125.014157
BibTeX
@article{Younis2026,
author = {Younis, Arwa and Demian, Joe and Bifulco, Savannah and Lehn, Lauren and Liuba, Ioan and Hinds, Samuel and Santangeli, Pasquale and Hussein, Ayman A and Mdaihly, Mohamad and Taigen, Tyler L and Tabaja, Chadi and Nakagawa, Hiroshi and Farwati, Medhat and Kleve, Ryan and Mora Ramirez, Marijose and Saliba, Walid I and Kanj, Mohamed and Garrott, Kara and Wazni, Oussama M},
title = {Factors Influencing Lesion Titration in a Monopolar Pulsed-Field Ablation Point Catheter: A Preclinical Study},
journal = {Circulation: Arrhythmia and Electrophysiology},
year = {2026},
doi = {10.1161/circep.125.014157}
}
EUVIMED