Load-Bearing Capacity of All-Ceramic Fixed Partial Dentures - Do In Vitro Tests Overestimate Strength?
The International Journal of Prosthodontics · 2025
DOI: 10.11607/ijp.9375 ↗Kurz gefasst
Fachartikel in der Zeitschrift The International Journal of Prosthodontics, 2025. Verfasst von Kurt-Jürgen Erdelt und 4 weiteren Autor:innen. Hauptthemen laut MEDLINE: Zirconium, Denture, Partial, Fixed, Dental Stress Analysis, Ceramics.
Abstract (Originalsprache)
PURPOSE: To assess the impact of the testing model on the load-bearing capacity of monolithic zirconia three-unit fixed dental prostheses (FDPs) and to discuss its implications for transferring in vitro results to clinical reality. MATERIALS AND METHODS: In total, 32 CAD-designed three-unit FDPs milled from zirconia were resin-bonded to four different types of die models (n = 8 each): PM (models made from PMMA); FR (fiberglass-reinforced polymer models), NP (CoCr-alloy models), and TM (tooth mobility simulation models). Load-to-failure testing was performed, and data were analyzed (P < .05). RESULTS: The mean fracture values were 1,676 ± 210 MPa in group TM, 1,820 ± 203 MPa in group PM, 2,266 ± 138 MPa in group FR, and 4,847 ± 496 MPa in group NP. All direct pairwise comparisons, except for TM and PM, showed significant differences. CONCLUSIONS: The results suggest that the nature of the underlying model has significant impact on the fracture values of all-ceramic FDPs in in vitro testing. Therefore, the validity of in vitro tests regarding clinical relevance must be questioned, emphasizing the necessity of a close-to-reality and highly standardized testing method.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Zitieren
APA
Erdelt, K. J., Schweiger, J., Bäumer, M., Edelhoff, D., & Schubert, O. (2025). Load-Bearing Capacity of All-Ceramic Fixed Partial Dentures - Do In Vitro Tests Overestimate Strength?. The International Journal of Prosthodontics. https://doi.org/10.11607/ijp.9375
Vancouver
Erdelt KJ, Schweiger J, Bäumer M, Edelhoff D, Schubert O. Load-Bearing Capacity of All-Ceramic Fixed Partial Dentures - Do In Vitro Tests Overestimate Strength?. The International Journal of Prosthodontics. 2025. doi:10.11607/ijp.9375
BibTeX
@article{Erdelt2025,
author = {Erdelt, Kurt-Jürgen and Schweiger, Josef and Bäumer, Monika and Edelhoff, Daniel and Schubert, Oliver},
title = {Load-Bearing Capacity of All-Ceramic Fixed Partial Dentures - Do In Vitro Tests Overestimate Strength?},
journal = {The International Journal of Prosthodontics},
year = {2025},
doi = {10.11607/ijp.9375}
}
EUVIMED