EUVIMEDEUVIMED entdecken
Crossref

THE EFFECT OF CEMENT AND SCREW ON THE RESISTANCE OF AN IMPLANT CROWN TELESCOPICALLY ENGAGED TO A HEXAGONAL-SHAPED ABUTMENT UNDER COMPRESSIVE DYNAMIC CYCLIC FATIGUE LOADING

Jan C Kwan, Norman Kwan

The International Journal of Prosthodontics · 2024

DOI: 10.11607/ijp.8362 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The International Journal of Prosthodontics, 2024. Verfasst von Jan C Kwan und 1 weiteren Autor:innen. Hauptthemen laut MEDLINE: Crowns, Dental Abutments, Dental Stress Analysis, Dental Restoration Failure. Die Arbeit wurde bisher 1-mal zitiert (Crossref).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: To investigate the resistance of an implant crown telescopically engaged to a geometrically defined hexagonal abutment with and without cement under compressive dynamic cyclic fatigue loading. MATERIALS AND METHODS: 40 crowns, 9 mm in height, were cast from prefabricated plastic copings, each telescopically engaged to a 3-mm-high machined hexagonal abutment. 20 crowns were retained with zinc phosphate cement, and 20 crowns were retained with a screw. A vertical load of 15 kg was applied to all samples under oscilla)on. A Periotest was used to measure the mobility of the implant crown in Periotest values (PTV). Test endpoints were defined by the following: fatigue cycles ≥ 20 million; crown PTV > 10; or if samples became visibly loose or component fracture. RESULTS: Cement-retained crowns failed on average at 2.60 x 106 cycles ± 2.27, while screw-retained crown samples failed at 2.17 x 106 cycles ± 1.27 with no significant difference (P > .05). Implant and abutment screw fractures were the most prevalent mode of failure in the cement-retained group, while in the screw-retained group, failures were caused by the loosening of one or both screw joints. The rate of increase in PTV was higher in the screw-retained group than in the cement-retained group. CONCLUSIONS: Under the experimental conditions, an implant crown telescopically engaged vertically to a 3-mm-tall hexagonal abutment, under compressive dynamic cyclic fatigue loading with or without cement, demonstrated no differences in resistance or failure outcomes. A cement-retained implant crown with telescopic engagement to the abutment is more rigid, resulting in more implant and abutment screw fractures than loosening.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

CrownsDental AbutmentsDental Stress AnalysisDental Restoration FailureDental Implant-Abutment DesignDental CementsMaterials TestingDental Prosthesis, Implant-SupportedCompressive StrengthZinc Phosphate CementHumansDental Prosthesis DesignCementation

Stichwörter der Autor:innen

Dynamic Cyclic Fatigue LoadingEmergence ProfileImplant CrownScrew vs Cement RetentionSet ScrewTelescopic Engagement

Substanzen

Dental CementsZinc Phosphate Cement

Zitieren

APA

Kwan, J. C., & Kwan, N. (2024). THE EFFECT OF CEMENT AND SCREW ON THE RESISTANCE OF AN IMPLANT CROWN TELESCOPICALLY ENGAGED TO A HEXAGONAL-SHAPED ABUTMENT UNDER COMPRESSIVE DYNAMIC CYCLIC FATIGUE LOADING. The International Journal of Prosthodontics. https://doi.org/10.11607/ijp.8362

Vancouver

Kwan JC, Kwan N. THE EFFECT OF CEMENT AND SCREW ON THE RESISTANCE OF AN IMPLANT CROWN TELESCOPICALLY ENGAGED TO A HEXAGONAL-SHAPED ABUTMENT UNDER COMPRESSIVE DYNAMIC CYCLIC FATIGUE LOADING. The International Journal of Prosthodontics. 2024. doi:10.11607/ijp.8362

BibTeX
@article{Kwan2024,
  author = {Kwan, Jan C and Kwan, Norman},
  title = {THE EFFECT OF CEMENT AND SCREW ON THE RESISTANCE OF AN IMPLANT CROWN TELESCOPICALLY ENGAGED TO A HEXAGONAL-SHAPED ABUTMENT UNDER COMPRESSIVE DYNAMIC CYCLIC FATIGUE LOADING},
  journal = {The International Journal of Prosthodontics},
  year = {2024},
  doi = {10.11607/ijp.8362}
}
Kostenlos starten →