EUVIMEDAtrasti EUVIMED
Crossref

3D EVALUATION OF MICROGAPS AT THE IMPLANT-ABUTMENT CONNECTION BEFORE AND AFTER THERMODYNAMIC CYCLING

Tuğçe Çetin, Y Umut Aslan

The International Journal of Prosthodontics · 2024

DOI: 10.11607/ijp.8308 ↗

At a glance

Journal article in The International Journal of Prosthodontics, 2024. Written by Tuğçe Çetin and 1 co-authors. Major MEDLINE topics: Thermodynamics. Cited 2 times so far (Crossref).

SantraukaSubjectsBibliografiniai duomenysCiteRelated studies

Abstract (original language)

PURPOSE: To analyze the microgap changes between hybrid-abutment crowns made of two materials and three internal taper connec9on implants with different connection designs before and after thermodynamic loading. MATERIALS AND METHODS: A total of 30 implants-10 each of Straumann Bone Level Implant-RC (STR); GC AADVA Implant (AAD); and Astra-Tech OsseoSpeed EV (AST)-were included in this laboratory study. Each implant had an internal taper connection, but their designs were slightly different. Five hybrid-abutment crowns were fabricated using a lithium disilicate ceramic (LD), and five were fabricated using polymethylmethacrylate (PMMA) with CAD/CAM technologies for each implant system, providing six sample groups STR-LD, AAD-LD, AST-LD, STR-PMMA, AAD-PMMA, and ASTPMMA. The microgap volume was measured using micro-CT images obtained before and after thermodynamic loading equivalent to 4 months of clinical use. Student t test, one-way ANOVA, and Tukey test were used for comparisons. RESULTS: The greatest microgap volume increase was recorded (3.405% ± 1.567%) in the AST-LD group, and the lowest increase (0.45% ± 0.373%) was in the STR-PMMA group. A statistically significant difference in microgap increase was not detected among PMMA and LD groups: for STR-LD/STR-PMMA (t test: P = .273); for AAD-LD/AAD-PMMA (t test: P = .374); and for AST-LD/AST-PMMA (t test: P = .268). However, the difference in the microgap increase between the different implant systems was statistically significant. CONCLUSIONS: The microgap between hybrid-abutment crowns and implants increased after short-term thermodynamic cycling. Hybrid-abutment crowns with different elastic modulus showed similar microgap increase. The geometric shape of the connection influenced the microgap increase.

Subjects

MeSH terms (MEDLINE)

ThermodynamicsDental PorcelainPolymethyl MethacrylateX-Ray MicrotomographyDental Implant-Abutment DesignCrownsImaging, Three-DimensionalComputer-Aided DesignDental Stress AnalysisHumansMaterials TestingDental Abutments

Substances

Dental PorcelainPolymethyl Methacrylatelithia disilicate

Cite

APA

Çetin, T., & Aslan, Y. U. (2024). 3D EVALUATION OF MICROGAPS AT THE IMPLANT-ABUTMENT CONNECTION BEFORE AND AFTER THERMODYNAMIC CYCLING. The International Journal of Prosthodontics. https://doi.org/10.11607/ijp.8308

Vancouver

Çetin T, Aslan YU. 3D EVALUATION OF MICROGAPS AT THE IMPLANT-ABUTMENT CONNECTION BEFORE AND AFTER THERMODYNAMIC CYCLING. The International Journal of Prosthodontics. 2024. doi:10.11607/ijp.8308

BibTeX
@article{etin2024,
  author = {Çetin, Tuğçe and Aslan, Y Umut},
  title = {3D EVALUATION OF MICROGAPS AT THE IMPLANT-ABUTMENT CONNECTION BEFORE AND AFTER THERMODYNAMIC CYCLING},
  journal = {The International Journal of Prosthodontics},
  year = {2024},
  doi = {10.11607/ijp.8308}
}
Start for free →