Evaluation of axial displacement and torque loss of Morse-type prosthetic abutments of different angular tapers to their respective implants

José Roberto de Freitas, Mariana Lima da Costa Valente, Elisabeth Helena Brazão, Izabela Cristina Maurício Moris, João Felipe Bonatto Bruniera, Yara Teresinha Corrêa Silva-Sousa, Edson Alfredo

The Journal of Prosthetic Dentistry · 2024

DOI: 10.1016/j.prosdent.2024.08.006 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The Journal of Prosthetic Dentistry, 2024. Verfasst von José Roberto de Freitas und 6 weiteren Autor:innen. Beteiligte Einrichtung: Professor, School of Dentistry, University of Ribeirão Preto (UNAERP), Ribeirão Preto, Brazil. Hauptthemen laut MEDLINE: Torque, Dental Abutments, Dental Implant-Abutment Design. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 57 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

STATEMENT OF PROBLEM: The biomechanical stability of the implant-prosthesis assembly and its maintenance under function is a determining factor in the success of implant prosthesis rehabilitation, but studies of different angular tapers are lacking. PURPOSE: The purpose of this in vitro study was to evaluate the axial displacement and torque loss of prosthetic abutments with Morse-type connections of different angular tapers after thermomechanical cycling by using microcomputed tomography (µCT) and a digital torque wrench. MATERIAL AND METHODS: Eighteen Ø3.5×11.5-mm implants were embedded in polyvinyl chloride cylinders, and the 3 different types of abutments (n=6) with angular tapers of 11.5 degrees - Alvim Cone Morse (ACM-11.5), 16.0 degrees - Helix Gran Morse (HGM-16), and 24.0 degrees - Nobel Replace Conical Connection (NRC-24) were installed with the torque recommended by the manufacturers. To calculate the axial displacements of the abutments about the implants, zirconia maxillary canine crowns were fabricated using a computer-aided design and computer-aided manufacturing (CAD-CAM) system and cemented onto the abutments. Before and after thermomechanical cycling, the assemblies were scanned using microtomography (micro-CT) to assess axial displacement, and the torque losses were calculated after the abutments were finally unscrewed. A load of 100 N, frequency of 2 Hz, and 106 cycles with temperature variation of 5 °C to 55 °C were used for the thermomechanical cycling. Analysis of variance and the Tukey post hoc test (α=.05) were used for analysis. RESULTS: A significant difference was observed between the abutments for axial displacement, measured after thermomechanical cycling (P=.002). The ACM-11.5 abutment showed the highest mean value (134.1 ±58.7 µm), different from HGM-16 (63.3 ±26.1 µm) (P=.013) and NRC-24 (42.7 ±8.7 µm) (P=.002); the 2 latter groups were similar to each other (P=.618). For the torque losses, no significant difference was found among the abutments (P=.928), but there were significant differences for the thermomechanical cycling (before and after) (P

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

TorqueDental AbutmentsDental Implant-Abutment DesignDental Stress AnalysisDental ImplantsHumansX-Ray MicrotomographyIn Vitro TechniquesComputer-Aided DesignZirconiumCrowns

Substanzen

Dental ImplantsZirconium

Autor:innen und Institutionen

  • Professor, School of Dentistry, University of Ribeirão Preto (UNAERP), Ribeirão Preto, Brazil.
  • Doctoral student, School of Dentistry, University of Ribeirão Preto (UNAERP), Ribeirão Preto, Brazil.
  • Professor, School of Dentistry, University of Ribeirão Preto (UNAERP), Ribeirão Preto, Brazil. Electronic address: ealfredo@unaerp.br.

Zitieren

APA

de Freitas, J. R., Valente, M. L. D. C., Brazão, E. H., Moris, I. C. M., Bruniera, J. F. B., Silva-Sousa, Y. T. C., & Alfredo, E. (2024). Evaluation of axial displacement and torque loss of Morse-type prosthetic abutments of different angular tapers to their respective implants. The Journal of Prosthetic Dentistry. https://doi.org/10.1016/j.prosdent.2024.08.006

Vancouver

de Freitas JR, Valente MLDC, Brazão EH, Moris ICM, Bruniera JFB, Silva-Sousa YTC, et al. Evaluation of axial displacement and torque loss of Morse-type prosthetic abutments of different angular tapers to their respective implants. The Journal of Prosthetic Dentistry. 2024. doi:10.1016/j.prosdent.2024.08.006

BibTeX
@article{deFreitas2024,
  author = {de Freitas, José Roberto and Valente, Mariana Lima da Costa and Brazão, Elisabeth Helena and Moris, Izabela Cristina Maurício and Bruniera, João Felipe Bonatto and Silva-Sousa, Yara Teresinha Corrêa and Alfredo, Edson},
  title = {Evaluation of axial displacement and torque loss of Morse-type prosthetic abutments of different angular tapers to their respective implants},
  journal = {The Journal of Prosthetic Dentistry},
  year = {2024},
  doi = {10.1016/j.prosdent.2024.08.006}
}
Kostenlos starten →