Evaluation of axial displacement and torque loss of Morse-type prosthetic abutments of different angular tapers to their respective implants
The Journal of Prosthetic Dentistry · 2024
DOI: 10.1016/j.prosdent.2024.08.006 ↗Kurz gefasst
Fachartikel in der Zeitschrift The Journal of Prosthetic Dentistry, 2024. Verfasst von José Roberto de Freitas und 6 weiteren Autor:innen. Beteiligte Einrichtung: Professor, School of Dentistry, University of Ribeirão Preto (UNAERP), Ribeirão Preto, Brazil. Hauptthemen laut MEDLINE: Torque, Dental Abutments, Dental Implant-Abutment Design. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 57 Literaturangaben.
Abstract (Originalsprache)
STATEMENT OF PROBLEM: The biomechanical stability of the implant-prosthesis assembly and its maintenance under function is a determining factor in the success of implant prosthesis rehabilitation, but studies of different angular tapers are lacking. PURPOSE: The purpose of this in vitro study was to evaluate the axial displacement and torque loss of prosthetic abutments with Morse-type connections of different angular tapers after thermomechanical cycling by using microcomputed tomography (µCT) and a digital torque wrench. MATERIAL AND METHODS: Eighteen Ø3.5×11.5-mm implants were embedded in polyvinyl chloride cylinders, and the 3 different types of abutments (n=6) with angular tapers of 11.5 degrees - Alvim Cone Morse (ACM-11.5), 16.0 degrees - Helix Gran Morse (HGM-16), and 24.0 degrees - Nobel Replace Conical Connection (NRC-24) were installed with the torque recommended by the manufacturers. To calculate the axial displacements of the abutments about the implants, zirconia maxillary canine crowns were fabricated using a computer-aided design and computer-aided manufacturing (CAD-CAM) system and cemented onto the abutments. Before and after thermomechanical cycling, the assemblies were scanned using microtomography (micro-CT) to assess axial displacement, and the torque losses were calculated after the abutments were finally unscrewed. A load of 100 N, frequency of 2 Hz, and 106 cycles with temperature variation of 5 °C to 55 °C were used for the thermomechanical cycling. Analysis of variance and the Tukey post hoc test (α=.05) were used for analysis. RESULTS: A significant difference was observed between the abutments for axial displacement, measured after thermomechanical cycling (P=.002). The ACM-11.5 abutment showed the highest mean value (134.1 ±58.7 µm), different from HGM-16 (63.3 ±26.1 µm) (P=.013) and NRC-24 (42.7 ±8.7 µm) (P=.002); the 2 latter groups were similar to each other (P=.618). For the torque losses, no significant difference was found among the abutments (P=.928), but there were significant differences for the thermomechanical cycling (before and after) (P
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Professor, School of Dentistry, University of Ribeirão Preto (UNAERP), Ribeirão Preto, Brazil.
- Doctoral student, School of Dentistry, University of Ribeirão Preto (UNAERP), Ribeirão Preto, Brazil.
- Professor, School of Dentistry, University of Ribeirão Preto (UNAERP), Ribeirão Preto, Brazil. Electronic address: ealfredo@unaerp.br.
Zitieren
APA
de Freitas, J. R., Valente, M. L. D. C., Brazão, E. H., Moris, I. C. M., Bruniera, J. F. B., Silva-Sousa, Y. T. C., & Alfredo, E. (2024). Evaluation of axial displacement and torque loss of Morse-type prosthetic abutments of different angular tapers to their respective implants. The Journal of Prosthetic Dentistry. https://doi.org/10.1016/j.prosdent.2024.08.006
Vancouver
de Freitas JR, Valente MLDC, Brazão EH, Moris ICM, Bruniera JFB, Silva-Sousa YTC, et al. Evaluation of axial displacement and torque loss of Morse-type prosthetic abutments of different angular tapers to their respective implants. The Journal of Prosthetic Dentistry. 2024. doi:10.1016/j.prosdent.2024.08.006
BibTeX
@article{deFreitas2024,
author = {de Freitas, José Roberto and Valente, Mariana Lima da Costa and Brazão, Elisabeth Helena and Moris, Izabela Cristina Maurício and Bruniera, João Felipe Bonatto and Silva-Sousa, Yara Teresinha Corrêa and Alfredo, Edson},
title = {Evaluation of axial displacement and torque loss of Morse-type prosthetic abutments of different angular tapers to their respective implants},
journal = {The Journal of Prosthetic Dentistry},
year = {2024},
doi = {10.1016/j.prosdent.2024.08.006}
}
EUVIMED