Instant variable stiffness in cardiovascular catheters based on fiber jamming
Science Advances · 2025-02-07 · 11 (6)
DOI: 10.1126/sciadv.adn1207 ↗At a glance
Journal article in Science Advances, published on 2025-02-07. Written by Yi Sun and 7 co-authors. Institution: Laboratory of Intelligent Systems, École Polytechnique Fédérale de Lausanne, 1015 Lausanne, Switzerland. Major MEDLINE topics: Cardiac Catheters, Minimally Invasive Surgical Procedures. Cited 23 times so far (Crossref); 39 references. The full text is freely available in PubMed Central.
Abstract (original language)
Variable stiffness (VS) has revolutionized miniature surgical instruments, including cardiovascular catheters for minimally invasive surgeries (MISs), enabling advanced capabilities in stiffness modulation and multi-curvature bending. However, existing VS catheters with phase-changing materials are slow in softening and stiffening rates (≈90 s), which can lead to substantial increase in surgery duration. To address the slow stiffness change, we propose a VS catheter based on fiber jamming (FJ) that achieves instant stiffness changes (≤300 ms), enabling seamless catheter operations without delays. Moreover, our catheter, incorporating hundreds of ultrathin fibers into a slender 2.3-mm catheter body, achieves up to 6.5-fold stiffness changes. With adequate stiffness change, our two-segment catheter achieves complex bending profiles within seconds. In addition, the FJ-based design does not require electric currents or heating inside the human body, minimizing patient risks. This FJ-based VS catheter, with instantaneous response, adequate stiffness change, and enhanced safety, can potentially establish benchmarks in MIS, allowing medical practitioners to effectively address formidable diseases.
Subjects
MeSH terms (MEDLINE)
Authors and institutions
- Laboratory of Intelligent Systems, École Polytechnique Fédérale de Lausanne, 1015 Lausanne, Switzerland.
- Multi-Scale Robotics Laboratory, Eidgenössische Technische Hochschule Zürich, 8092 Zürich, Switzerland.
- 1st Department of Internal Medicine, Cardioangiology, St. Anne's University Hospital in Brno and Faculty of Medicine of Masaryk University, Brno, Czech Republic.
- Interventional Cardiac Electrophysiology Group, International Clinical Research Center, St. Anne's University Hospital Brno, Pekařská 53, 602 00 Brno, Czech Republic.
ORCID profiles: Yi Sun, Yegor Piskarev, Quentin Boehler, Zdeněk Stárek, Bradley J Nelson, Dario Floreano
Cite
APA
Sun, Y., Piskarev, Y., Hofstetter, E. H., Fischer, C., Boehler, Q., Stárek, Z., Nelson, B. J., & Floreano, D. (2025). Instant variable stiffness in cardiovascular catheters based on fiber jamming. Science Advances, 11(6). https://doi.org/10.1126/sciadv.adn1207
Vancouver
Sun Y, Piskarev Y, Hofstetter EH, Fischer C, Boehler Q, Stárek Z, et al. Instant variable stiffness in cardiovascular catheters based on fiber jamming. Science Advances. 2025;11(6). doi:10.1126/sciadv.adn1207
BibTeX
@article{Sun2025,
author = {Sun, Yi and Piskarev, Yegor and Hofstetter, Etienne H and Fischer, Cedric and Boehler, Quentin and Stárek, Zdeněk and Nelson, Bradley J and Floreano, Dario},
title = {Instant variable stiffness in cardiovascular catheters based on fiber jamming},
journal = {Science Advances},
year = {2025},
volume = {11},
number = {6},
doi = {10.1126/sciadv.adn1207}
}
EUVIMED