EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Bench Testing Analysis of Perforation Management in the Setting of Bifurcation Coronary Intervention

Rayyan Hemetsberger, Anass Maaroufi iD, Kevin Hamzaraj, Judit Andreka iD, Mohammad Abdelghani iD, Serdar Farhan, Daniel Lootz, Johannes Gollmer, Nader Mankerious, Christian Hengstenberg, Tom W Johnson, Gabor G Toth

Catheterization and Cardiovascular Interventions · 2026-03 · 107 (4) · 888-897

DOI: 10.1002/ccd.70406 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Catheterization and Cardiovascular Interventions, online erschienen am 12.12.2025. Verfasst von Rayyan Hemetsberger und 11 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, Internal Medicine II, Medical University of Vienna, Vienna, Austria. Hauptthemen laut MEDLINE: Drug-Eluting Stents, Coronary Vessels, Percutaneous Coronary Intervention, Angioplasty, Balloon, Coronary. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 12 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Biotronik, Abbott, and Novomed.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Management of coronary perforation in bifurcation lesions with covered stents remains challenging.

Aims

We aimed to describe a proper practice and toolbox for “jailed‐branch” management after covered stent deployment.

Methods

Using a bench model, we tested various wires with a 120° angulated microcatheter for their ability to penetrate covered stents to access jailed side branches (SB). Next, four PCI techniques were assessed: Test #1 (main branch [MB] rupture simulation): MB covered stent, graft penetration, and kissing balloon inflation (KBI) ( n = 7). Test #2: Test #1 completed with Culotte using a drug‐eluting stent (DES) ( n = 3). Test #3: Culotte with two covered stents simulating MB and SB rupture ( n = 3). Test #4: Test #3 plus final DES in MB ( n = 3).

Results

High tip‐load wires ( > 12 g) successfully penetrated covered stents within 14 s. All procedures were completed successfully. Test #1 showed lumen area reductions of –8% (MB) and –25% (SB), with graft overhang at the SB. Conversion to Culotte with DES (Test #2) improved SB lumen reduction to –8%. Test #3 showed reductions of –7% (MB) and –15% (SB), with graft overhang at MB, corrected in Test #4 by DES implantation, resulting in +9% lumen gain (MB) and improved SB lumen reduction (–11%).

Conclusion

In this bifurcation perforation in‐bench model, high tip‐load wires effectively penetrated covered stents toward excluded branches after crossover covered stent implantation. Conversion to Culotte, using either a DES or a second covered stent, was feasible. Overhanging graft material following SB fenestration could be addressed by overstenting with a DES.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Drug-Eluting StentsCoronary VesselsPercutaneous Coronary InterventionAngioplasty, Balloon, CoronaryCoronary Artery DiseaseHeart InjuriesHumansProsthesis DesignMaterials TestingCardiac CathetersModels, CardiovascularModels, Anatomic

Stichwörter der Autor:innen

Culottebifurcation perforationcomplicationcovered stentin‐bench test

Autor:innen und Institutionen

  • Department of Cardiology, Internal Medicine II, Medical University of Vienna, Vienna, Austria.
  • University Heart Center Graz, Medical University Graz, Graz, Austria.
  • Cardiology Unit, Sohar Hospital, Sohar, Oman.
  • Cardiology Department, Al-Azhar University, Cairo, Egypt.
  • Cardiology Department, Amsterdam University Medical Center, University of Amsterdam, Amsterdam, the Netherlands.
  • Lenox Hill Hospital, Northwell Health, Donald and Barbara Zucker School of Medicine at Hofstra/Northwell, New York, New York, USA.

ORCID-Profile: Anass Maaroufi, Judit Andreka, Mohammad Abdelghani

Förderung

  • Biotronik, Abbott, and Novomed

Zitieren

APA

Hemetsberger, R., Maaroufi, A., Hamzaraj, K., Andreka, J., Abdelghani, M., Farhan, S., Lootz, D., Gollmer, J., Mankerious, N., Hengstenberg, C., Johnson, T. W., & Toth, G. G. (2026). Bench Testing Analysis of Perforation Management in the Setting of Bifurcation Coronary Intervention. Catheterization and Cardiovascular Interventions, 107(4), 888-897. https://doi.org/10.1002/ccd.70406

Vancouver

Hemetsberger R, Maaroufi A, Hamzaraj K, Andreka J, Abdelghani M, Farhan S, et al. Bench Testing Analysis of Perforation Management in the Setting of Bifurcation Coronary Intervention. Catheterization and Cardiovascular Interventions. 2026;107(4):888-897. doi:10.1002/ccd.70406

BibTeX
@article{Hemetsberger2026,
  author = {Hemetsberger, Rayyan and Maaroufi, Anass and Hamzaraj, Kevin and Andreka, Judit and Abdelghani, Mohammad and Farhan, Serdar and Lootz, Daniel and Gollmer, Johannes and Mankerious, Nader and Hengstenberg, Christian and Johnson, Tom W and Toth, Gabor G},
  title = {Bench Testing Analysis of Perforation Management in the Setting of Bifurcation Coronary Intervention},
  journal = {Catheterization and Cardiovascular Interventions},
  year = {2026},
  volume = {107},
  number = {4},
  pages = {888--897},
  doi = {10.1002/ccd.70406}
}
Kostenlos starten →