EUVIMEDEUVIMED entdecken
Open Access

Failure Mechanisms in Off-Label Electrosurgery Devices for BASILICA, LAMPOON, and SESAME

Jaime L Murray, Andre R Montes, Andrea E Jaimes, Robert J Lederman, D Korel Yildirim

JACC: Cardiovascular Interventions · 2026

DOI: 10.1016/j.jcin.2026.05.006 ↗

Kurz gefasst

Fachartikel in der Zeitschrift JACC: Cardiovascular Interventions, 2026. Verfasst von Jaime L Murray und 4 weiteren Autor:innen. Beteiligte Einrichtung: Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda, Maryland,…. Hauptthemen laut MEDLINE: Electrosurgery, Cardiac Catheters, Sesamum, Cardiac Catheterization. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 9 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: Intramural NIH HHS, NHLBI DIR.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Transcatheter electrosurgery using off-label guidewire-catheter systems to traverse or lacerate tissue may fail unexpectedly or cause nontarget heating. OBJECTIVES: The aim of this study was to identify mechanisms of energy loss and nontarget heating in off-label transcatheter electrosurgery systems. METHODS: The authors simulated electrosurgical traversal and flying-V laceration used in BASILICA (bioprosthetic or native aortic scallop intentional laceration to prevent iatrogenic coronary artery obstruction), LAMPOON (laceration of the anterior mitral leaflet to prevent outflow obstruction), and SESAME (septal scoring along the midline endocardium) in a 2-compartment benchtop model. Current distribution and regional heating were measured in metallic-braided and nonmetallic catheter assemblies. RESULTS: Longer, higher power energy applications caused substantial catheter shaft heating and diverted energy delivery away from traversal or laceration targets. This reflected coupling between the guidewire and metallic catheter components and was amplified by thermal damage to insulation. Shorter, lower power applications and nonmetallic catheters reduced these effects. In SESAME, the risk for dangerous intramyocardial heating was reduced by connecting the intracavitary limb of the flying-V to the electrosurgery generator, instead of the intramyocardial limb. CONCLUSIONS: Metallic braiding in commonly used microcatheters can divert energy away from electrosurgical targets to catheter shafts and cause clinically important nontarget heating. In this benchtop model, energy applications of ≤2 seconds largely avoided these failure modes. Operators should favor nonmetallic catheters when feasible, use the shortest effective energy applications, and in SESAME energize the intracavitary limb. Purpose-built electrosurgical devices may improve safety and reliability.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ElectrosurgeryCardiac CathetersSesamumCardiac CatheterizationEquipment DesignHot TemperatureEquipment FailureHumansEquipment Failure AnalysisMaterials TestingModels, CardiovascularOcimum basilicum

Stichwörter der Autor:innen

leaflet modificationradiofrequency wiresafetysteam poptranscatheter electrosurgery

Autor:innen und Institutionen

  • Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda, Maryland, USA.
  • Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda, Maryland, USA. Electronic address: lederman@nih.gov.

Förderung

  • Intramural NIH HHS
  • NHLBI DIR

Zitieren

APA

Murray, J. L., Montes, A. R., Jaimes, A. E., Lederman, R. J., & Yildirim, D. K. (2026). Failure Mechanisms in Off-Label Electrosurgery Devices for BASILICA, LAMPOON, and SESAME. JACC: Cardiovascular Interventions. https://doi.org/10.1016/j.jcin.2026.05.006

Vancouver

Murray JL, Montes AR, Jaimes AE, Lederman RJ, Yildirim DK. Failure Mechanisms in Off-Label Electrosurgery Devices for BASILICA, LAMPOON, and SESAME. JACC: Cardiovascular Interventions. 2026. doi:10.1016/j.jcin.2026.05.006

BibTeX
@article{Murray2026,
  author = {Murray, Jaime L and Montes, Andre R and Jaimes, Andrea E and Lederman, Robert J and Yildirim, D Korel},
  title = {Failure Mechanisms in Off-Label Electrosurgery Devices for BASILICA, LAMPOON, and SESAME},
  journal = {JACC: Cardiovascular Interventions},
  year = {2026},
  doi = {10.1016/j.jcin.2026.05.006}
}
Kostenlos starten →