Instant variable stiffness in cardiovascular catheters based on fiber jamming
Science Advances · 07.02.2025 · 11 (6)
DOI: 10.1126/sciadv.adn1207 ↗Kurz gefasst
Fachartikel in der Zeitschrift Science Advances, erschienen am 07.02.2025. Verfasst von Yi Sun und 7 weiteren Autor:innen. Beteiligte Einrichtung: Laboratory of Intelligent Systems, École Polytechnique Fédérale de Lausanne, 1015 Lausanne, Switzerland. Hauptthemen laut MEDLINE: Cardiac Catheters, Minimally Invasive Surgical Procedures. Die Arbeit wurde bisher 23-mal zitiert (Crossref) und nennt 39 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
Variable stiffness (VS) has revolutionized miniature surgical instruments, including cardiovascular catheters for minimally invasive surgeries (MISs), enabling advanced capabilities in stiffness modulation and multi-curvature bending. However, existing VS catheters with phase-changing materials are slow in softening and stiffening rates (≈90 s), which can lead to substantial increase in surgery duration. To address the slow stiffness change, we propose a VS catheter based on fiber jamming (FJ) that achieves instant stiffness changes (≤300 ms), enabling seamless catheter operations without delays. Moreover, our catheter, incorporating hundreds of ultrathin fibers into a slender 2.3-mm catheter body, achieves up to 6.5-fold stiffness changes. With adequate stiffness change, our two-segment catheter achieves complex bending profiles within seconds. In addition, the FJ-based design does not require electric currents or heating inside the human body, minimizing patient risks. This FJ-based VS catheter, with instantaneous response, adequate stiffness change, and enhanced safety, can potentially establish benchmarks in MIS, allowing medical practitioners to effectively address formidable diseases.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Laboratory of Intelligent Systems, École Polytechnique Fédérale de Lausanne, 1015 Lausanne, Switzerland.
- Multi-Scale Robotics Laboratory, Eidgenössische Technische Hochschule Zürich, 8092 Zürich, Switzerland.
- 1st Department of Internal Medicine, Cardioangiology, St. Anne's University Hospital in Brno and Faculty of Medicine of Masaryk University, Brno, Czech Republic.
- Interventional Cardiac Electrophysiology Group, International Clinical Research Center, St. Anne's University Hospital Brno, Pekařská 53, 602 00 Brno, Czech Republic.
ORCID-Profile: Yi Sun, Yegor Piskarev, Quentin Boehler, Zdeněk Stárek, Bradley J Nelson, Dario Floreano
Zitieren
APA
Sun, Y., Piskarev, Y., Hofstetter, E. H., Fischer, C., Boehler, Q., Stárek, Z., Nelson, B. J., & Floreano, D. (2025). Instant variable stiffness in cardiovascular catheters based on fiber jamming. Science Advances, 11(6). https://doi.org/10.1126/sciadv.adn1207
Vancouver
Sun Y, Piskarev Y, Hofstetter EH, Fischer C, Boehler Q, Stárek Z, et al. Instant variable stiffness in cardiovascular catheters based on fiber jamming. Science Advances. 2025;11(6). doi:10.1126/sciadv.adn1207
BibTeX
@article{Sun2025,
author = {Sun, Yi and Piskarev, Yegor and Hofstetter, Etienne H and Fischer, Cedric and Boehler, Quentin and Stárek, Zdeněk and Nelson, Bradley J and Floreano, Dario},
title = {Instant variable stiffness in cardiovascular catheters based on fiber jamming},
journal = {Science Advances},
year = {2025},
volume = {11},
number = {6},
doi = {10.1126/sciadv.adn1207}
}