Continuous carbon dioxide monitoring in the exhaled breath of mechanically ventilated rats
Experimental Physiology · 2025
DOI: 10.1113/ep093058 ↗Kurz gefasst
Fachartikel in der Zeitschrift Experimental Physiology, 2025. Verfasst von Christin Wenzel und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Anesthesiology and Critical Care, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germa…. Hauptthemen laut MEDLINE: Carbon Dioxide, Respiration, Artificial, Exhalation. Die Arbeit nennt 17 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: DFG grant SCHU.
Abstract (Originalsprache)
In small animals, carbon dioxide monitoring is either limited by the need to take blood samples for gas analysis, or it interferes with respiratory efficiency and lung mechanics analysis. We introduced a novel approach for continuous monitoring of CO 2 in the expiratory limb of the breathing circuit. The relevance of the method is assessed by CO 2 measurements at different respiratory settings. Rats were ventilated with a tidal volume ( V T ) of 8 mL kg −1 . Respiratory rates were adjusted to achieve arterial CO 2 partial pressure () between 35 and 45 mmHg. We measured partial pressure of CO 2 in the expiratory limb of the breathing circuit (exCO 2 ). exCO 2 values were compared to from blood gas analysis. The agreement between the two measurements was assessed by correlation and Bland–Altman analysis. The validity of the novel approach was established through additional experimental runs with V T of 7 or 6 mL kg −1 , where the respiratory rate was set in accordance to exCO 2 . Measurements of exCO 2 reflected with high correlation ( R 2 = 0.8658). Bland–Altman analysis showed high agreement between the two measurements. Respiratory rate setting guided by exCO 2 (39 ± 2 or 40 ± 2 mmHg during ventilation with V T of 7 or 6 mL kg −1 , respectively) was appropriate to maintain (41 ± 2 mmHg for both V T ). Measurement of exCO 2 provides a robust estimate of in anaesthetized small animals during mechanical ventilation. Continuous monitoring of CO 2 in the exhaled breath could be used to guide mechanical ventilation settings.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Anesthesiology and Critical Care, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany.
ORCID-Profile: Christin Wenzel, Sashko Spassov
Förderung
- DFG grant SCHU
Zitieren
APA
Wenzel, C., Borgmann, S., Flamm, B., Kuhn, L., Schumann, S., Schmidt, J., Spaeth, J., & Spassov, S. (2025). Continuous carbon dioxide monitoring in the exhaled breath of mechanically ventilated rats. Experimental Physiology. https://doi.org/10.1113/ep093058
Vancouver
Wenzel C, Borgmann S, Flamm B, Kuhn L, Schumann S, Schmidt J, et al. Continuous carbon dioxide monitoring in the exhaled breath of mechanically ventilated rats. Experimental Physiology. 2025. doi:10.1113/ep093058
BibTeX
@article{Wenzel2025,
author = {Wenzel, Christin and Borgmann, Silke and Flamm, Bernd and Kuhn, Lea and Schumann, Stefan and Schmidt, Johannes and Spaeth, Johannes and Spassov, Sashko},
title = {Continuous carbon dioxide monitoring in the exhaled breath of mechanically ventilated rats},
journal = {Experimental Physiology},
year = {2025},
doi = {10.1113/ep093058}
}
EUVIMED