Exhaled Carbon Dioxide Monitoring Using Instantaneous CO 2 Mode During High‐Frequency Oscillatory Ventilation in Very Low Birth Weight Infants
Pediatric Pulmonology · 2025
DOI: 10.1002/ppul.71323 ↗Kurz gefasst
Fachartikel in der Zeitschrift Pediatric Pulmonology, 2025. Verfasst von Yusuke Nakazawa und 4 weiteren Autor:innen. Beteiligte Einrichtung: Nakazawa Kodomo Clinic, Shizuoka, Japan. Hauptthemen laut MEDLINE: Carbon Dioxide, High-Frequency Ventilation, Infant, Very Low Birth Weight. Die Arbeit nennt 14 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: The authors received no specific funding for this work..
Abstract (Originalsprache)
Background
High‐frequency oscillatory ventilation (HFOV) presents challenges for noninvasive CO 2 monitoring due to its rapid oscillations. This study examines the feasibility of instantaneous CO 2 partial pressure (INST CO 2 ) monitoring during HFOV with a capnometer equipped with a mainstream CO 2 sensor.
Methods
This study included seven neonates receiving HFOV in the neonatal intensive care unit (NICU) at Shizuoka Children's Hospital. INST CO 2 values were recorded over 3‐ and 5‐min intervals surrounding each blood gas sampling to determine the maximum INST CO 2 value (INST CO 2 MX). The primary outcome was the correlation between INST CO 2 MX and arterial partial pressure of carbon dioxide (PCO 2 ).
Results
A total of 216 paired INST CO 2 MX and PCO 2 values were analyzed. The coefficient of determination ( R 2 ) was 0.571 for INST CO 2 MX (3 min) and 0.579 for INST CO 2 MX (5 min). Univariable and multivariable analyses revealed that a lower fraction of inspired oxygen (FiO 2 ), reduced minute ventilation, and increased postnatal age were associated with improved concordance between INST CO 2 MX and PCO 2 .
Conclusion
INST CO 2 MX demonstrated a strong correlation with PCO 2 in neonates undergoing HFOV. This novel, noninvasive monitoring approach may serve as a valuable tool for neonatal respiratory management. Future research is needed to validate these findings in broader patient populations and across various ventilatory settings.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Nakazawa Kodomo Clinic, Shizuoka, Japan.
- Division of Neonatology, Center for Maternal-Neonatal Care, Nagoya University Hospital, Nagoya, Japan.
- Department of Pediatrics, Toyota Memorial Hospital, Toyota, Japan.
ORCID-Profile: Kazuto Ueda, Yoshiaki Sato
Förderung
- The authors received no specific funding for this work.
Zitieren
APA
Nakazawa, Y., Ueda, K., Tanahashi, Y., Aoki, T., & Sato, Y. (2025). Exhaled Carbon Dioxide Monitoring Using Instantaneous CO 2 Mode During High‐Frequency Oscillatory Ventilation in Very Low Birth Weight Infants. Pediatric Pulmonology. https://doi.org/10.1002/ppul.71323
Vancouver
Nakazawa Y, Ueda K, Tanahashi Y, Aoki T, Sato Y. Exhaled Carbon Dioxide Monitoring Using Instantaneous CO 2 Mode During High‐Frequency Oscillatory Ventilation in Very Low Birth Weight Infants. Pediatric Pulmonology. 2025. doi:10.1002/ppul.71323
BibTeX
@article{Nakazawa2025,
author = {Nakazawa, Yusuke and Ueda, Kazuto and Tanahashi, Yoshihiro and Aoki, Toshiki and Sato, Yoshiaki},
title = {Exhaled Carbon Dioxide Monitoring Using Instantaneous CO 2 Mode During High‐Frequency Oscillatory Ventilation in Very Low Birth Weight Infants},
journal = {Pediatric Pulmonology},
year = {2025},
doi = {10.1002/ppul.71323}
}
EUVIMED