EUVIMEDEUVIMED entdecken
Open Access

Effects of Lung Injury and Abdominal Insufflation on Respiratory Mechanics and Lung Volume During Time-Controlled Adaptive Ventilation

Harry Ramcharran, Gregory Wetmore, Scott Cooper, Jacob Herrmann, Andrea Fonseca da Cruz, David W Kaczka, Joshua Satalin, Sarah Blair, Penny L Andrews, Nader M Habashi, Gary F Nieman, Michaela Kollisch-Singule

Respiratory Care · 2024-11 · 69 (11) · 1432-1443

DOI: 10.4187/respcare.11745 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Respiratory Care, online erschienen am 25.10.2024. Verfasst von Harry Ramcharran und 11 weiteren Autor:innen. Beteiligte Einrichtung: Department of Surgery, SUNY Upstate Medical University, Syracuse, New York. Hauptthemen laut MEDLINE: Insufflation, Respiratory Mechanics, Lung Volume Measurements, Lung Injury. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 57 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NHLBI NIH HHS, NIGMS NIH HHS.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUD: Lung volume measurements are important for monitoring functional aeration and recruitment and may help guide adjustments in ventilator settings. The expiratory phase of airway pressure release ventilation (APRV) may provide physiologic information about lung volume based on the expiratory flow-time slope, angle, and time to approach a no-flow state (expiratory time [T E ]). We hypothesized that expiratory flow would correlate with estimated lung volume (ELV) as measured using a modified nitrogen washout/washin technique in a large-animal lung injury model. METHODS: Eight pigs (35.2 ± 1.0 kg) were mechanically ventilated using an Engström Carescape R860 on the APRV mode. All settings were held constant except the expiratory duration, which was adjusted based on the expiratory flow curve. Abdominal pressure was increased to 15 mm Hg in normal and injured lungs to replicate a combination of pulmonary and extrapulmonary lung injury. ELV was estimated using the Carescape FRC INview tool. The expiratory flow-time slope and T E were measured from the expiratory flow profile. RESULTS: Lung elastance increased with induced lung injury from 29.3 ± 7.3 cm H 2 O/L to 39.9 ± 15.1cm H 2 O/L, and chest wall elastance increased with increasing intra-abdominal pressures (IAPs) from 15.3 ± 4.1 cm H 2 O/L to 25.7 ± 10.0 cm H 2 O/L in the normal lung and 15.8 ± 6.0 cm H 2 O/L to 33.0 ± 6.2 cm H 2 O/L in the injured lung ( P = .39). ELV decreased from 1.90 ± 0.83 L in the injured lung to 0.67 ± 0.10 L by increasing IAP to 15 mm Hg. This had a significant correlation with a T E decrease from 2.3 ± 0.8 s to 1.0 ± 0.1 s in the injured group with increasing insufflation pressures (ρ = 0.95) and with the expiratory flow-time slope, which increased from 0.29 ± 0.06 L/s 2 to 0.63 ± 0.05 L/s 2 (ρ = 0.78). CONCLUSIONS: Changes in ELV over time, and the T E and flow-time slope, could be used to demonstrate evolving lung injury during APRV. Using the slope to infer changes in functional lung volume represents a unique, reproducible, real-time, bedside technique that does not interrupt ventilation and may be used for clinical interpretation.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

InsufflationRespiratory MechanicsLung Volume MeasurementsLung InjuryRespiration, ArtificialLungAnimalsSwineDisease Models, AnimalAbdomenTidal VolumeExhalation

Stichwörter der Autor:innen

airway pressure release ventilationend-expiratory lung volumeexpiratory flowtime-controlled adaptive ventilation

Autor:innen und Institutionen

  • Department of Surgery, SUNY Upstate Medical University, Syracuse, New York.
  • Department of Surgery, University of Cincinnati, Cincinnati, Ohio.
  • Department of Internal Medicine, Morehouse School of Medicine, Atlanta, Georgia.
  • Roy J. Carver Department of Biomedical Engineering, University of Iowa, Iowa City, Iowa.
  • Department of Anesthesia, University of Iowa, Iowa City, Iowa.
  • Roy J. Carver Department of Biomedical Engineering, University of Iowa, Iowa City, Iowa; Department of Anesthesia, University of Iowa, Iowa City, Iowa; and Department of Radiology, University of Iowa, Iowa City, Iowa.

Förderung

  • NHLBI NIH HHS
  • NIGMS NIH HHS

Zitieren

APA

Ramcharran, H., Wetmore, G., Cooper, S., Herrmann, J., Fonseca da Cruz, A., Kaczka, D. W., Satalin, J., Blair, S., Andrews, P. L., Habashi, N. M., Nieman, G. F., & Kollisch-Singule, M. (2024). Effects of Lung Injury and Abdominal Insufflation on Respiratory Mechanics and Lung Volume During Time-Controlled Adaptive Ventilation. Respiratory Care, 69(11), 1432-1443. https://doi.org/10.4187/respcare.11745

Vancouver

Ramcharran H, Wetmore G, Cooper S, Herrmann J, Fonseca da Cruz A, Kaczka DW, et al. Effects of Lung Injury and Abdominal Insufflation on Respiratory Mechanics and Lung Volume During Time-Controlled Adaptive Ventilation. Respiratory Care. 2024;69(11):1432-1443. doi:10.4187/respcare.11745

BibTeX
@article{Ramcharran2024,
  author = {Ramcharran, Harry and Wetmore, Gregory and Cooper, Scott and Herrmann, Jacob and Fonseca da Cruz, Andrea and Kaczka, David W and Satalin, Joshua and Blair, Sarah and Andrews, Penny L and Habashi, Nader M and Nieman, Gary F and Kollisch-Singule, Michaela},
  title = {Effects of Lung Injury and Abdominal Insufflation on Respiratory Mechanics and Lung Volume During Time-Controlled Adaptive Ventilation},
  journal = {Respiratory Care},
  year = {2024},
  volume = {69},
  number = {11},
  pages = {1432--1443},
  doi = {10.4187/respcare.11745}
}
Kostenlos starten →