Film dosimetry for occupant exposure monitoring within Far‐UVC installations
Photochemistry and Photobiology · 2025-01 · 101 (1) · 157-166
DOI: 10.1111/php.13960 ↗At a glance
Journal article in Photochemistry and Photobiology, published online on 2024-05-03. Written by David Welch and 5 co-authors. Institution: Center for Radiological Research, Columbia University Irving Medical Center, New York, New York, USA. Major MEDLINE topics: Ultraviolet Rays, Film Dosimetry. Cited 10 times so far (Crossref); 21 references. The full text is freely available (open access, CC BY 4.0). Funded by: Columbia University Urban Tech Award, Open Philanthropy Foundation, NIOSH CDC HHS.
Abstract (original language)
Far‐UVC radiation between 200 and 230 nm is a promising technology for reducing airborne disease transmission. Previous work with far‐UVC lamps has demonstrated the efficacy of far‐UVC radiation to inactivate bacteria and viruses while presenting minimal human health hazards. While far‐UVC intentionally exposes the occupied space, effectively disinfecting air between occupants, installations must still ensure that occupant eye and skin exposure is within the recommended daily limits. This study examines far‐UVC‐sensitive films for measuring the dose received by occupants within two real‐world far‐UVC installations. The film is characterized for accuracy, angular response, wavelength response, and sources of uncertainty in film response, and used to obtain individual exposure doses that account for both the non‐uniform irradiance and the unique motion of individuals within the space. Dosimetry results using the films, which account for the time‐weighted average exposure of an occupant, ranged from 10% to 49% of the maximum calculated stationary dose based on peak irradiance measurements. Results from this study spotlight the need to incorporate time‐weighted average considerations into the design and safety assessment of far‐UVC installations to ultimately operate far‐UVC technology with its full potential to prevent the spread of potentially fatal infectious diseases.
Subjects
MeSH terms (MEDLINE)
Author keywords
Authors and institutions
- Center for Radiological Research, Columbia University Irving Medical Center, New York, New York, USA.
- College of Dental Medicine, Columbia University Irving Medical Center, New York, New York, USA.
- Division of Global Health Equity, Brigham & Women's Hospital, Harvard Medical School, Boston, Massachusetts, USA.
ORCID profiles: Edward Nardell
Funding
- Columbia University Urban Tech Award
- Open Philanthropy Foundation
- NIOSH CDC HHS
- Empire State Biodefense Commercialization Fund
- National Institute for Occupational Safety and Health
Cite
APA
Welch, D., Hashmi, R., Petersen, C., Erde, S., Brenner, D. J., & Nardell, E. (2025). Film dosimetry for occupant exposure monitoring within Far‐UVC installations. Photochemistry and Photobiology, 101(1), 157-166. https://doi.org/10.1111/php.13960
Vancouver
Welch D, Hashmi R, Petersen C, Erde S, Brenner DJ, Nardell E. Film dosimetry for occupant exposure monitoring within Far‐UVC installations. Photochemistry and Photobiology. 2025;101(1):157-166. doi:10.1111/php.13960
BibTeX
@article{Welch2025,
author = {Welch, David and Hashmi, Raabia and Petersen, Camryn and Erde, Steven and Brenner, David J and Nardell, Edward},
title = {Film dosimetry for occupant exposure monitoring within Far‐UVC installations},
journal = {Photochemistry and Photobiology},
year = {2025},
volume = {101},
number = {1},
pages = {157--166},
doi = {10.1111/php.13960}
}
EUVIMED