Purpose
Evidence on the accuracy and reproducibility of the virtual interocclusal registration procedure over an implant‐supported prosthesis is lacking. The aim of this clinical study was to evaluate the correlation between the virtual occlusal scheme designed by computer‐aided design software and the occlusal scheme obtained clinically on a single implant‐retained monolithic crown and its adjacent teeth. Materials and Methods The virtual occlusal scheme design of 25 single implant‐retained monolithic crowns and their adjacent teeth was obtained using an intraoral scanning system. These registrations were compared with conventional occlusal records obtained by applying articulating paper in two stages: first with 200 µm blue film and second with 12 µm metallic red articulation tape. The data were analyzed using Wilcoxon Signed Ranks Tests to compare paired samples.
Results
A total of 25 patients with 25 crowns were examined and an average of 2 clinical contacts was obtained for each crown, whereas a mean of 3 contacts was obtained virtually. For the adjacent teeth, both the distal and the mesial, a mean of two contacts was observed both clinically and virtually. A statistically significant difference was found between clinical and virtual implant crowns in both the quantity ( p = 0.022) and quality of these contacts ( p = 0.011).
Conclusions
This study revealed significant differences between clinical and virtual implant crown contacts, both in terms of the quantity and quality of contacts. In contrast, adjacent teeth exhibited comparable numbers of contacts across methods, although notable differences in quality were observed.
Zitieren
APA
Biadsee, A., Hamed, S., & Ormianer, Z. (2026). Clinical evaluation of the accuracy of static interocclusal single screw‐retained implant records designed by a CAD–CAM system: A comparative in vivo study. Journal of Prosthodontics. https://doi.org/10.1111/jopr.70276
Vancouver
Biadsee A, Hamed S, Ormianer Z. Clinical evaluation of the accuracy of static interocclusal single screw‐retained implant records designed by a CAD–CAM system: A comparative in vivo study. Journal of Prosthodontics. 2026. doi:10.1111/jopr.70276
BibTeX
@article{Biadsee2026,
author = {Biadsee, Ameer and Hamed, Sondos and Ormianer, Zeev},
title = {Clinical evaluation of the accuracy of static interocclusal single screw‐retained implant records designed by a CAD–CAM system: A comparative in vivo study},
journal = {Journal of Prosthodontics},
year = {2026},
doi = {10.1111/jopr.70276}
}
EUVIMED