A COMPARATIVE STUDY ON IMPLANT PLACEMENT ACCURACY BETWEEN VACUUM-FORMED THERMOPLASTIC GUIDES AND CAD-CAM 3D PRINTED GUIDES
International Journal of Drug Delivery Technology · 08.07.2026 · 16 (63s)
DOI: 10.25258/ijddt.16.63s.94 ↗Kurz gefasst
Fachartikel in der Zeitschrift International Journal of Drug Delivery Technology, online erschienen am 08.07.2026. Verfasst von Patel Rushit und 5 weiteren Autor:innen.
Abstract (Originalsprache)
Background
Surgical guides play an important role in transferring virtual implant planning to the clinical setting. The accuracy of implant placement may vary depending on the guide fabrication technique.
Aim
To compare the implant placement accuracy of vacuum-formed thermoplastic guides and CAD-CAM fabricated 3D printed surgical guides. Materials and Methods: This comparative clinical study included 48 implant sites in 15 partially edentulous patients. Implant sites were allocated to either thermoplastic surgical guides (n=24) or CAD-CAM 3D printed surgical guides (n=24). Preoperative and postoperative CBCT scans were used to assess coronal, apical, angular, and depth deviations between planned and actual implant positions. Statistical analysis was performed using an independent sample t-test.
Results
The 3D printed guide group showed significantly lower coronal deviation (0.80 ± 0.21 mm vs. 1.45 ± 0.31 mm), apical deviation (1.12 ± 0.28 mm vs. 1.68 ± 0.42 mm), angular deviation (2.93 ± 0.92° vs. 5.84 ± 1.28°), and depth deviation (0.64 ± 0.14 mm vs. 1.18 ± 0.30 mm) compared with the thermoplastic guide group (p < 0.05).
Conclusion
CAD-CAM fabricated 3D printed surgical guides demonstrated significantly greater implant placement accuracy than conventional thermoplastic guides and may provide a more predictable approach for guided implant surgery.
Zitieren
APA
Rushit, P., Ankita, S., Mansi, M., Poojan, S., Snehal, P., & Ojas, V. (2026). A COMPARATIVE STUDY ON IMPLANT PLACEMENT ACCURACY BETWEEN VACUUM-FORMED THERMOPLASTIC GUIDES AND CAD-CAM 3D PRINTED GUIDES. International Journal of Drug Delivery Technology, 16(63s). https://doi.org/10.25258/ijddt.16.63s.94
Vancouver
Rushit P, Ankita S, Mansi M, Poojan S, Snehal P, Ojas V. A COMPARATIVE STUDY ON IMPLANT PLACEMENT ACCURACY BETWEEN VACUUM-FORMED THERMOPLASTIC GUIDES AND CAD-CAM 3D PRINTED GUIDES. International Journal of Drug Delivery Technology. 2026;16(63s). doi:10.25258/ijddt.16.63s.94
BibTeX
@article{Rushit2026,
author = {Rushit, Patel and Ankita, Sahal and Mansi, Mankodiya and Poojan, Shah and Snehal, Pandoriya and Ojas, Variava},
title = {A COMPARATIVE STUDY ON IMPLANT PLACEMENT ACCURACY BETWEEN VACUUM-FORMED THERMOPLASTIC GUIDES AND CAD-CAM 3D PRINTED GUIDES},
journal = {International Journal of Drug Delivery Technology},
year = {2026},
volume = {16},
number = {63s},
doi = {10.25258/ijddt.16.63s.94}
}
EUVIMED