Comparative Analysis of Dynamic Versus Static Navigation in Implant Placement Accuracy
Journal of Pharmacy and Bioallied Sciences · 2025-12 · 17 (Suppl 4) · S3090-S3092
DOI: 10.4103/jpbs.jpbs_1172_25 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Pharmacy and Bioallied Sciences, online erschienen am 17.12.2025. Verfasst von Pratesh Nitin Dholabhai und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Oral and Maxillofacial Surgery, K. M. Shah Dental College and Hospital, Sumandeep Vidyapeeth (Deemed to be University), Vadodara, Gujar…. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 13 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
Background
Precision in implant placement is a critical determinant of clinical success in implant dentistry. Computer-aided navigation systems, including static and dynamic modalities, have been developed to enhance accuracy. However, comparative data evaluating their effectiveness remain limited.
Objective
This study aimed to compare the accuracy of implant placement using dynamic navigation versus static guided systems in terms of angular deviation, global entry deviation, and apical deviation. Materials and Methods: A total of 40 implants were placed in 20 partially edentulous patients. Each patient received two implants: one using static navigation and the other with dynamic navigation. Postoperative cone beam computed tomography scans were analyzed using specialized implant planning software to calculate deviations in implant position relative to preoperative planning. Mean deviations were compared using paired t -tests.
Results
The mean angular deviation was significantly lower in the dynamic navigation group (2.15° ±0.68°) compared to the static group (3.74° ±1.12°; P < 0.001). Entry point deviation averaged 0.78 ± 0.25 mm for dynamic navigation and 1.14 ± 0.38 mm for static guidance ( P = 0.003). Apical deviation was 1.12 ± 0.31 mm for dynamic navigation versus 1.55 ± 0.49 mm for static navigation ( P = 0.001).
Conclusion
Dynamic navigation demonstrated superior accuracy compared to static guidance in implant placement. These findings suggest that dynamic systems may offer clinicians enhanced control and precision, especially in anatomically complex cases.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Oral and Maxillofacial Surgery, K. M. Shah Dental College and Hospital, Sumandeep Vidyapeeth (Deemed to be University), Vadodara, Gujarat, India.
- Department of Dentistry, All India Institute of Medical Sciences, Rajkot, Gujarat, India.
- Department of Periodontics, Saveetha Dental College and Hospitals, Saveetha Institute of Medical and Technical Sciences (SIMATS), Chennai, Tamil Nadu, India.
- Department of Restorative Dentistry, Mahsa University, Selangor, Malaysia.
- Department of Conservative Dentistry and Endodontics, Kalinga Institute of Dental Sciences, KIIT Deemed to be University, Bhubaneswar, Odisha, India.
- Department of Oral and Maxillofacial Surgery, Inderprastha Dental College and Hospital, Ghaziabad, Uttar Pradesh, India.
Zitieren
APA
Dholabhai, P. N., Parmar, V., Ramamurthy, J., Abo Arsheed, N. A., Mohanty, A., & Gupta, S. (2025). Comparative Analysis of Dynamic Versus Static Navigation in Implant Placement Accuracy. Journal of Pharmacy and Bioallied Sciences, 17(Suppl 4), S3090-S3092. https://doi.org/10.4103/jpbs.jpbs_1172_25
Vancouver
Dholabhai PN, Parmar V, Ramamurthy J, Abo Arsheed NA, Mohanty A, Gupta S. Comparative Analysis of Dynamic Versus Static Navigation in Implant Placement Accuracy. Journal of Pharmacy and Bioallied Sciences. 2025;17(Suppl 4):S3090-S3092. doi:10.4103/jpbs.jpbs_1172_25
BibTeX
@article{Dholabhai2025,
author = {Dholabhai, Pratesh Nitin and Parmar, Vijay and Ramamurthy, Jaiganesh and Abo Arsheed, Noor Addeen and Mohanty, Adyasha and Gupta, Sameer},
title = {Comparative Analysis of Dynamic Versus Static Navigation in Implant Placement Accuracy},
journal = {Journal of Pharmacy and Bioallied Sciences},
year = {2025},
volume = {17},
number = {Suppl 4},
pages = {S3090--S3092},
doi = {10.4103/jpbs.jpbs_1172_25}
}
EUVIMED