EUVIMEDEUVIMED entdecken
Randomisierte kontrollierte StudieOpen Access · CC BY 4.0

Transfer accuracy of three different virtually designed CAD/CAM retainers – baseline results of a randomized clinical trial

Felix Linnerz, Rana Victoria Aghamiri, Inas Ayad, Mette Kuijpers, Jan Willem Hoekstra, Sachin Chhatwani, Gholamreza Danesh, Stephan Christian Möhlhenrich

Clinical Oral Investigations · 09.03.2026 · 30 (3)

DOI: 10.1007/s00784-026-06789-9 ↗

Kurz gefasst

Randomisierte kontrollierte Studie in der Zeitschrift Clinical Oral Investigations, online erschienen am 09.03.2026. Verfasst von Felix Linnerz und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthodontics, Witten/Herdecke University, Alfred-Herrhausen Str. 45, 58455, Witten, Germany. Hauptthemen laut MEDLINE: Computer-Aided Design, Orthodontic Retainers, Orthodontic Appliance Design. Die Arbeit nennt 33 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

This study aimed to evaluate the immediate three-dimensional (3D) transfer accuracy of three virtually designed CAD/CAM lingual retainers fabricated from nickel–titanium (NiTi), titanium grade 5 (Ti5), and cobalt–chromium (CoCr). The investigation represents the baseline (T = 0) phase of a registered randomized clinical trial (DRKS00028974). Materials and methods Sixty patients (32 females, 28 males; mean age 19.2 ± 6.9 years) were randomly allocated to receive one of the three CAD/CAM retainers. Immediately after bonding (T0–T1), intraoral scans were superimposed with the digital design to determine deviations at predefined interproximal contact points. Non-parametric Kruskal–Wallis tests with Dunn’s post-hoc comparisons were applied (p ≤ 0.05).

Results

All 60 patients completed the baseline assessment. Transfer deviations were lowest in the NiTi group (0.17 mm, IQR 0.16–0.21), followed by Ti5 (0.37 mm, IQR 0.32–0.41) and CoCr (0.35 mm, IQR 0.30–0.40). NiTi showed significantly higher transfer accuracy compared with Ti5 (p < 0.001) and CoCr (p < 0.001). No significant difference was observed between Ti5 and CoCr (p > 0.999). No adverse events occurred.

Conclusions

Laser-cut NiTi CAD/CAM retainers demonstrated significantly higher immediate transfer precision than milled Ti5 and CoCr retainers. These findings represent the baseline phase of the ongoing randomized clinical trial; subsequent analyses will determine whether such accuracy differences translate into clinically relevant stability outcomes. Clinical relevance Accurate passive fit of CAD/CAM retainers is essential to prevent unwanted forces on teeth. Understanding material-dependent transfer deviations may improve digital bonding workflows and guide material selection in clinical orthodontics.

Trial registration

DRKS00028974 (registered May 2022)

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Computer-Aided DesignOrthodontic RetainersOrthodontic Appliance DesignHumansFemaleMaleYoung AdultAdolescentTitaniumDental Alloys

Stichwörter der Autor:innen

Cobalt–chromiumComputer-aided designLingual retentionNickel–titaniumOrthodontic retainersTransfer accuracy

Substanzen

TitaniumDental Alloys

Autor:innen und Institutionen

  • Department of Orthodontics, Witten/Herdecke University, Alfred-Herrhausen Str. 45, 58455, Witten, Germany.
  • Department of Dentistry, Section of Orthodontics, Dentofacial Orthopedics and Craniofacial Biology, Radboud University Medical Centre, THK 309, P.O. Box 9101, Nijmegen, 6500 HB, The Netherlands.
  • Department of Orthodontics, Witten/Herdecke University, Alfred-Herrhausen Str. 45, 58455, Witten, Germany. stephan.moehlhenrich@radboudumc.nl.
  • Department of Dentistry, Section of Orthodontics, Dentofacial Orthopedics and Craniofacial Biology, Radboud University Medical Centre, THK 309, P.O. Box 9101, Nijmegen, 6500 HB, The Netherlands. stephan.moehlhenrich@rad…

Zitieren

APA

Linnerz, F., Aghamiri, R. V., Ayad, I., Kuijpers, M., Hoekstra, J. W., Chhatwani, S., Danesh, G., & Möhlhenrich, S. C. (2026). Transfer accuracy of three different virtually designed CAD/CAM retainers – baseline results of a randomized clinical trial. Clinical Oral Investigations, 30(3). https://doi.org/10.1007/s00784-026-06789-9

Vancouver

Linnerz F, Aghamiri RV, Ayad I, Kuijpers M, Hoekstra JW, Chhatwani S, et al. Transfer accuracy of three different virtually designed CAD/CAM retainers – baseline results of a randomized clinical trial. Clinical Oral Investigations. 2026;30(3). doi:10.1007/s00784-026-06789-9

BibTeX
@article{Linnerz2026,
  author = {Linnerz, Felix and Aghamiri, Rana Victoria and Ayad, Inas and Kuijpers, Mette and Hoekstra, Jan Willem and Chhatwani, Sachin and Danesh, Gholamreza and Möhlhenrich, Stephan Christian},
  title = {Transfer accuracy of three different virtually designed CAD/CAM retainers – baseline results of a randomized clinical trial},
  journal = {Clinical Oral Investigations},
  year = {2026},
  volume = {30},
  number = {3},
  doi = {10.1007/s00784-026-06789-9}
}
Kostenlos starten →