In vitro comparison of physical characteristics of milled versus printed zirconia discs
Journal of Prosthodontics · 2024-12 · 33 (9) · 891-898
DOI: 10.1111/jopr.13778 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Journal of Prosthodontics, 2023-11. Verfasst von Thomas S Giugliano und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Prosthodontics, New York University College of Dentistry, New York, New York, USA. Hauptthemen laut MEDLINE: Zirconium, Printing, Three-Dimensional, Computer-Aided Design, Materials Testing. Die Arbeit wurde bisher 18-mal zitiert (Crossref) und nennt 36 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NIDCR NIH HHS, National Institutes of Health/National Institute of Dental and Craniofacial Research.
Abstract (Originalsprache)
Purpose
The purpose of this study was to compare the dimensional accuracy, translucency, and biaxial flexural strength of milled zirconia (MZ) versus 3D‐printed zirconia (PZ) discs. Materials & Methods A circular disc measuring 14.0 mm in diameter and 1.20 mm in thickness was designed using computer‐aided design (CAD) software. The resulting standard tessellation language (STL) file was used both as a control and to fabricate 36 zirconia (3Y‐TZP) disc specimens ( n = 36): 18 were milled (group MZ) and 18 were 3D‐printed (group PZ). The diameter and thickness of each disc were measured using a digital caliper. Translucency was evaluated using a calibrated dental colorimeter. The flexural strength was determined using the piston‐on‐three‐ball biaxial flexure test. All measurements were done by one blinded examiner. The statistical significance level was set to α = 0.05.
Results
The MZ discs had significantly more accurate dimensions than the PZ discs in both diameter and thickness when compared to the control CAD software‐designed disc. The MZ discs exhibited significantly higher translucency (translucency parameter (TP) = 16.95 ±0.36 vs. 9.24 ±1.98) and biaxial flexural strength (996.16 ±137.37 MPa vs. 845.75 ±266.16 MPa) than the PZ discs. Finally, MZ possessed a significantly higher Weibull modulus relative to PZ.
Conclusions
The results showed that the milled specimens achieved better dimensional accuracy and were more translucent, stronger, and less prone to failure than printed specimens.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Prosthodontics, New York University College of Dentistry, New York, New York, USA.
- Laboratories for Microstructure Physics & Mechanics of Materials, Department of Preventive and Restorative Sciences, School of Dental Medicine, University of Pennsylvania, Philadelphia, Pennsylvania, USA.
- Department of Epidemiology & Health Promotion, New York University College of Dentistry, New York, New York, USA.
ORCID-Profile: Thomas S Giugliano, Mijin Choi
Förderung
- NIDCR NIH HHS
- National Institutes of Health/National Institute of Dental and Craniofacial Research
Zitieren
APA
Giugliano, T. S., Zhang, Y., Janal, M. N., Lim, C. H., Smith, R. M., & Choi, M. (2024). In vitro comparison of physical characteristics of milled versus printed zirconia discs. Journal of Prosthodontics, 33(9), 891-898. https://doi.org/10.1111/jopr.13778
Vancouver
Giugliano TS, Zhang Y, Janal MN, Lim CH, Smith RM, Choi M. In vitro comparison of physical characteristics of milled versus printed zirconia discs. Journal of Prosthodontics. 2024;33(9):891-898. doi:10.1111/jopr.13778
BibTeX
@article{Giugliano2024,
author = {Giugliano, Thomas S and Zhang, Yu and Janal, Malvin N and Lim, Chek Hai and Smith, Ruby M and Choi, Mijin},
title = {In vitro comparison of physical characteristics of milled versus printed zirconia discs},
journal = {Journal of Prosthodontics},
year = {2024},
volume = {33},
number = {9},
pages = {891--898},
doi = {10.1111/jopr.13778}
}
EUVIMED