Effect of thermal cycling on the flexure strength of CAD-CAM denture base materials: An in vitro study
The Journal of Prosthetic Dentistry · 2024-09 · 132 (3) · 645.e1-645.e7
DOI: 10.1016/j.prosdent.2024.07.005 ↗Kurz gefasst
Fachartikel in der Zeitschrift The Journal of Prosthetic Dentistry, 2024-09. Verfasst von Rui Li und 4 weiteren Autor:innen. Beteiligte Einrichtung: Assistant Professor, Restorative Dentistry Department, University at Buffalo School of Dental Medicine, Buffalo, NY. Hauptthemen laut MEDLINE: Denture Bases, Computer-Aided Design, Materials Testing, Flexural Strength. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 31 Literaturangaben. Gefördert von: University at Buffalo - The State University of New York.
Abstract (Originalsprache)
STATEMENT OF PROBLEM: The impact of thermal cycling on the flexure strength of contemporary denture base materials remains inadequately understood despite its crucial role in determining the long-term performance of complete dentures. PURPOSE: The purpose of this in vitro study was to evaluate the flexural strength of different CAD-CAM denture base materials and the effects of thermal cycling. MATERIAL AND METHODS: A total of 120 rectangular specimens were fabricated from 6 denture base materials according to the International Organization for Standardization (ISO) 20795-1:2013 standard: a heat-compressed PMMA ([Lucitone 199 [C-L199]), 2 brands of milled material (Ivotion Base [M-IB] and Lucitone Digital Fit [M-LDF]), and 3 types of 3- dimensionally (3D) printed material (Lucitone Digital Print [P-LDP], Flexcera Base [P-FB], and FotoDent Dentures [P-FD]). Specimens were divided into 2 subgroups of 10; half underwent thermocycling, half did not. Thermally cycled specimens were immersed in distilled water at 37 °C for 2 days, followed by 5000 thermal cycles at 5 and 55 ºC, with a dwell time of 30 seconds. They were then subjected to a 3-point flexural strength test. Two-way ANOVA, followed by post hoc Tukey multiple comparison tests were used to assess the effect of material type and the thermal cycling process on the flexural strength of denture base materials (α=.05). RESULTS: All materials met the ISO standard of 65 MPa flexural strength, except for thermal cycled P-FB. A significant difference (P M-IB≈P-FD≈P-LDP>C-L199≈ P-FB) and with thermal cycling (M-LDF> M-IB≈P-FD>P-LDP≈C-L199>P-FB). The flexural strength of tested materials was reduced significantly (P
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Assistant Professor, Restorative Dentistry Department, University at Buffalo School of Dental Medicine, Buffalo, NY.
- Prosthodontics Resident, University at Buffalo School of Dental Medicine, Buffalo, NY.
- Clinical Associate Professor, Restorative Dentistry Department, University at Buffalo School of Dental Medicine, Buffalo, NY.
- Director, Absolute Dental Services, Durham, NC.
- Professor, Department of Restorative Sciences, University of Alabama at Birmingham, School of Dentistry, Birmingham, Ala. Electronic address: rsadidzadeh@gmail.com.
Förderung
- University at Buffalo - The State University of New York
Zitieren
APA
Li, R., Albaghli, A., Orgev, A., Marrano, J., & Sadid-Zadeh, R. (2024). Effect of thermal cycling on the flexure strength of CAD-CAM denture base materials: An in vitro study. The Journal of Prosthetic Dentistry, 132(3), 645.e1-645.e7. https://doi.org/10.1016/j.prosdent.2024.07.005
Vancouver
Li R, Albaghli A, Orgev A, Marrano J, Sadid-Zadeh R. Effect of thermal cycling on the flexure strength of CAD-CAM denture base materials: An in vitro study. The Journal of Prosthetic Dentistry. 2024;132(3):645.e1-645.e7. doi:10.1016/j.prosdent.2024.07.005
BibTeX
@article{Li2024,
author = {Li, Rui and Albaghli, Abdullah and Orgev, Ahmet and Marrano, Jack and Sadid-Zadeh, Ramtin},
title = {Effect of thermal cycling on the flexure strength of CAD-CAM denture base materials: An in vitro study},
journal = {The Journal of Prosthetic Dentistry},
year = {2024},
volume = {132},
number = {3},
pages = {645.e1--645.e7},
doi = {10.1016/j.prosdent.2024.07.005}
}
EUVIMED