EUVIMEDObjevte EUVIMED
Crossref

Effect of different intraoral scanners and scanbody splinting on accuracy of scanning implant‐supported full arch fixed prosthesis

Yasmine Ashraf, Ahmad Abo El Fadl, Amina Hamdy, Kamal Ebeid

Journal of Esthetic and Restorative Dentistry · 2023-12 · 35 (8) · 1257-1263

DOI: 10.1111/jerd.13070 ↗

At a glance

Journal article in Journal of Esthetic and Restorative Dentistry, published online on 2023-06-13. Written by Yasmine Ashraf and 3 co-authors. Institution: Department of Fixed Prosthodontics, Faculty of Dentistry, Ain Shams University, Cairo, Egypt. Major MEDLINE topics: Imaging, Three-Dimensional, Dental Implants. Cited 38 times so far (Crossref); 47 references.

AbstraktSubjectsBibliografické údajeCiteRelated studies

Abstract (original language)

Objective

This study evaluated the accuracy of different intraoral scanners (IOS) for scanning of implant‐supported full arch fixed prosthesis with different implant angulations with and without scanbodies splinting. Materials and Methods Two maxillary models were designed and fabricated to receive an all‐on‐four implant retained. The models were divided into two groups according to the angulation of the posterior implant (Group 1; 30 and Group 2; 45). Each group was then divided into three subgroups according to the type of IOS used: Subgroup C; Primescan, subgroup T; Trios4, and subgroup M; Medit i600. Then each subgroup was divided into two divisions according to scanning technique; division S: splinted and division N: nonsplinted. Ten scans were made by each scanner for every division. Trueness and precision were analyzed using Geomagic controlX analysis software.

Results

Angulation had no significant effect on both the trueness ( p = 0.854) and precision ( p = 0.347). Splinting had a significant effect on trueness and precision ( p < 0.001). Scanner type had a significant effect on trueness ( p < 0.001) and precision ( p < 0.001). There was no significant difference between trueness of Trios 4 (112.15 ± 12.85) and Primescan (106.75 ± 22.58). However, there was a significant difference when compared to trueness of Medit i600 (158.50 ± 27.65). For the precision results Cerec Primescan showed the highest precision (95.45 ± 33.21). There was a significant difference between the three scanners, precision of Trios4 (109.72 ± 19.24) and Medit i600 (121.21 ± 17.26).

Conclusion

Cerec Primescan has higher trueness and precision than Trios 4 and Medit i600 in full arch implants scanning. Splinting the scanbodies improve the accuracy of full arch implants scanning. Clinical Significance Cerec Primescan and 3Shape Trios 4 can be used for scanning of All‐on‐four implant supported prosthesis when scanbodies are splinted using a modular chain device.

Subjects

MeSH terms (MEDLINE)

Imaging, Three-DimensionalDental ImplantsModels, DentalDental Impression TechniqueComputer-Aided DesignDental Arch

Author keywords

all-on-4dental implantsdigital dentistryfixed prosthodonticsimplant scanbody

Substances

Dental Implants

Authors and institutions

  • Department of Fixed Prosthodontics, Faculty of Dentistry, Ain Shams University, Cairo, Egypt.

Cite

APA

Ashraf, Y., Abo El Fadl, A., Hamdy, A., & Ebeid, K. (2023). Effect of different intraoral scanners and scanbody splinting on accuracy of scanning implant‐supported full arch fixed prosthesis. Journal of Esthetic and Restorative Dentistry, 35(8), 1257-1263. https://doi.org/10.1111/jerd.13070

Vancouver

Ashraf Y, Abo El Fadl A, Hamdy A, Ebeid K. Effect of different intraoral scanners and scanbody splinting on accuracy of scanning implant‐supported full arch fixed prosthesis. Journal of Esthetic and Restorative Dentistry. 2023;35(8):1257-1263. doi:10.1111/jerd.13070

BibTeX
@article{Ashraf2023,
  author = {Ashraf, Yasmine and Abo El Fadl, Ahmad and Hamdy, Amina and Ebeid, Kamal},
  title = {Effect of different intraoral scanners and scanbody splinting on accuracy of scanning implant‐supported full arch fixed prosthesis},
  journal = {Journal of Esthetic and Restorative Dentistry},
  year = {2023},
  volume = {35},
  number = {8},
  pages = {1257--1263},
  doi = {10.1111/jerd.13070}
}
Start for free →