EUVIMEDEUVIMED entdecken
Crossref

Influence of arch location and scanning pattern on the scanning accuracy, scanning time, and number of photograms of complete‐arch intraoral digital implant scans

Miguel Gómez-Polo, Rocío Cascos iD, Rocío Ortega, Abdul B Barmak, John C Kois, Marta Revilla-León iD

Clinical Oral Implants Research · 2023-06 · 34 (6) · 591-601

DOI: 10.1111/clr.14069 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Clinical Oral Implants Research, online erschienen am 13.04.2023. Verfasst von Miguel Gómez-Polo und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Conservative Dentistry and Prosthodontics, Director of Postgraduate Program of Advanced in Implant-Prosthodontics, School of Dentistry,…. Hauptthemen laut MEDLINE: Computer-Aided Design, Dental Implants. Die Arbeit wurde bisher 58-mal zitiert (Crossref) und nennt 52 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

To measure the influence of arch location and scanning pattern on the accuracy, scanning time, and number of photograms of complete‐arch implant scans acquired using an intraoral scanner (IOS). Materials and Methods A maxillary (maxillary group) and mandibular (mandibular group) model with 6 implant abutments on each cast was digitized using a desktop scanner (control scans). Six subgroups were created based on the scanning pattern used to acquire the scans using an IOS (Trios 4): occluso‐buccal‐lingual (OBL subgroup), occluso‐linguo‐buccal (OLB subgroup), bucco‐linguo‐occlusal (BLO subgroup), linguo‐buccal‐occlusal (LBO subgroup), zigzag (ZZ subgroup), and circumferential (C subgroup). The control scans were used as a reference to measure the discrepancy with the experimental scans calculating the root mean square error. Two‐way ANOVA and the pairwise comparison Tukey tests were used to analyze the data ( α = .05).

Results

Significant discrepancies in trueness ( p < .001 ), precision ( p < .001 ), scanning time ( p < .001 ), and number of photograms ( p < .001 ) were found. The maxillary group obtained poorer trueness and precision values, higher scanning times, and a larger number of photograms than the mandibular group. The C subgroup obtained the best trueness and precision values, but was not significantly different from the OLB, BLO, and LBO subgroups. The ZZ subgroup obtained the worst trueness and precision values ( p < .05 ). The C subgroup obtained the lowest scanning time and number of photograms ( p < .05 ).

Conclusions

Arch location and scanning pattern influenced scanning accuracy, scanning time, and number of photograms of complete‐arch implant scans.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Computer-Aided DesignDental ImplantsImaging, Three-DimensionalDental Impression TechniqueModels, DentalDental Arch

Stichwörter der Autor:innen

dental implantsintraoral scannersscanning accuracyscanning patternscanning strategy

Substanzen

Dental Implants

Autor:innen und Institutionen

  • Department of Conservative Dentistry and Prosthodontics, Director of Postgraduate Program of Advanced in Implant-Prosthodontics, School of Dentistry, Complutense University of Madrid, Madrid, Spain.
  • Advanced in Implant-Prosthodontics, School of Dentistry, Complutense University of Madrid, Madrid, Spain.
  • Department of Prosthetic Dentistry, School of Dentistry, European University of Madrid, Madrid, Spain.
  • Clinical Research and Biostatistics, Eastman Institute of Oral Health, University of Rochester Medical Center, Rochester, New York, USA.
  • Kois Center, Private Practice, University of Washington, Seattle, Washington, USA.
  • Graduate Prosthodontics, School of Dentistry, University of Washington, Seattle, Washington, USA.

ORCID-Profile: Rocío Cascos, Marta Revilla-León

Zitieren

APA

Gómez-Polo, M., Cascos, R., Ortega, R., Barmak, A. B., Kois, J. C., & Revilla-León, M. (2023). Influence of arch location and scanning pattern on the scanning accuracy, scanning time, and number of photograms of complete‐arch intraoral digital implant scans. Clinical Oral Implants Research, 34(6), 591-601. https://doi.org/10.1111/clr.14069

Vancouver

Gómez-Polo M, Cascos R, Ortega R, Barmak AB, Kois JC, Revilla-León M. Influence of arch location and scanning pattern on the scanning accuracy, scanning time, and number of photograms of complete‐arch intraoral digital implant scans. Clinical Oral Implants Research. 2023;34(6):591-601. doi:10.1111/clr.14069

BibTeX
@article{GmezPolo2023,
  author = {Gómez-Polo, Miguel and Cascos, Rocío and Ortega, Rocío and Barmak, Abdul B and Kois, John C and Revilla-León, Marta},
  title = {Influence of arch location and scanning pattern on the scanning accuracy, scanning time, and number of photograms of complete‐arch intraoral digital implant scans},
  journal = {Clinical Oral Implants Research},
  year = {2023},
  volume = {34},
  number = {6},
  pages = {591--601},
  doi = {10.1111/clr.14069}
}
Kostenlos starten →