EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Influence of scanbody design and intraoral scanner on the trueness of complete arch implant digital impressions: An in vitro study

Priscila Ceolin Meneghetti iD, Junying Li, Paulo Sérgio Borella, Gustavo Mendonça iD, Luiz Henrique Burnett iD

PLOS ONE · 2023

DOI: 10.1371/journal.pone.0295790 ↗

Kurz gefasst

Fachartikel in der Zeitschrift PLOS ONE, 2023. Verfasst von Priscila Ceolin Meneghetti und 4 weiteren Autor:innen. Beteiligte Einrichtung: School of Health and Life Sciences, Pontifical Catholic University of Rio Grande do Sul, Porto Alegre, Rio Grande do Sul, Brazil. Hauptthemen laut MEDLINE: Mouth, Edentulous, Dental Implants. Die Arbeit wurde bisher 32-mal zitiert (Crossref) und nennt 42 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study aimed to compare the accuracy of full-arch digital implant impressions using seven different scanbodies and four intraoral scanners. A 3D-printed maxillary model with six implants and their respective multi-unit abutments was used for this study. Seven scanbodies (SB1, SB2, SB3, SB4, SB5, SB6, and SB7) and four intraoral scanners (Primescan®, Omnican®, Trios 3®, and Trios 4®) were assessed. Each combination group was scanned ten times and a dental lab scanner (D2000, 3Shape) was used as a reference. All scans were exported as STL files, imported into Convince software (3Shape) for alignment, and later into Blender software, where their 3D positions were analyzed using a Python script. The 3D deviation, angular deviation, and linear distance between implants #3 and #14 were also measured. Accuracy was measured in terms of “trueness” (scanbody 3D deviation between intraoral scan and desktop scan). Kruskal-Wallis followed by the Bonferroni correction was used to analyze the data (⍺ = .05). The study found statistically significant differences in digital impression accuracy among the scanners and scanbodies (p

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Mouth, EdentulousDental ImplantsHumansImaging, Three-DimensionalComputer-Aided DesignModels, DentalProstheses and ImplantsDental Impression TechniqueDental Arch

Substanzen

Dental Implants

Autor:innen und Institutionen

  • School of Health and Life Sciences, Pontifical Catholic University of Rio Grande do Sul, Porto Alegre, Rio Grande do Sul, Brazil.
  • Department of Biological and Materials Sciences & Prosthodontics, University of Michigan School of Dentistry, Ann Arbor, Michigan, United States of America.
  • Department of General Practice, Virginia Commonwealth University School of Dentistry, Richmond, Virginia, United States of America.
  • Department of Occlusion, Fixed Prosthodontics, and Dental Materials, Federal University of Uberlândia, Uberlândia, Minas Gerais, Brazil.

ORCID-Profile: Priscila Ceolin Meneghetti, Gustavo Mendonça, Luiz Henrique Burnett

Zitieren

APA

Meneghetti, P. C., Li, J., Borella, P. S., Mendonça, G., & Burnett, L. H. (2023). Influence of scanbody design and intraoral scanner on the trueness of complete arch implant digital impressions: An in vitro study. PLOS ONE. https://doi.org/10.1371/journal.pone.0295790

Vancouver

Meneghetti PC, Li J, Borella PS, Mendonça G, Burnett LH. Influence of scanbody design and intraoral scanner on the trueness of complete arch implant digital impressions: An in vitro study. PLOS ONE. 2023. doi:10.1371/journal.pone.0295790

BibTeX
@article{Meneghetti2023,
  author = {Meneghetti, Priscila Ceolin and Li, Junying and Borella, Paulo Sérgio and Mendonça, Gustavo and Burnett, Luiz Henrique},
  title = {Influence of scanbody design and intraoral scanner on the trueness of complete arch implant digital impressions: An in vitro study},
  journal = {PLOS ONE},
  year = {2023},
  doi = {10.1371/journal.pone.0295790}
}
Kostenlos starten →