EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access · CC BY 4.0

Complete arch digital implant scan accuracy with screw-retained or snap-on scan bodies: A comparative in vitro study

Lorenzo Arcuri, Alessandro Pozzi, Jimmy Londono, Alessandra Nardi, Luca Testarelli, Massimo Galli

The Journal of Prosthetic Dentistry · 2025

DOI: 10.1016/j.prosdent.2025.04.003 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift The Journal of Prosthetic Dentistry, 2025. Verfasst von Lorenzo Arcuri und 5 weiteren Autor:innen. Beteiligte Einrichtung: Professor, Department of Life Science, Health and Health Professions, Link Campus University, Rome, Italy. Hauptthemen laut MEDLINE: Imaging, Three-Dimensional, Dental Implants, Dental Arch. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Ministero dell’Istruzione, dell’Università e della Ricerca.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

STATEMENT OF PROBLEM: Different scan body types have been reported to influence intraoral scanning accuracy. Stiff implant connections allow the use of snap-on scan bodies. However, data on the influence of scan body retention type are lacking. PURPOSE: The purpose of this in vitro study was to assess and compare the accuracy of complete arch digital scanning with that of screw-retained or snap-on scan bodies. MATERIAL AND METHODS: An edentulous mandibular master model with 4 conical connection analogs was digitized with an extraoral optical scanner to achieve a reference file. Seventy-six test scans were obtained with an intraoral scanner: 38 using screw-retained and 38 using snap-on scan bodies. The resulting 76 test files were aligned to the reference file with a best fit algorithm. Linear (ΔX, ΔY and ΔZ- axis), and angular deviations (ΔANGLE) were evaluated for each implant position (n=304). Three-dimensional (3D) deviation was calculated for each position according to the Euclidean distance (ΔEUC). Descriptive analysis and multivariable analysis were stratified considering scan body type and implant position (α=.05). RESULTS: Considering ΔEUC, scan body type showed no significant difference (P=.097), while implant position was statistically significant (P

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Imaging, Three-DimensionalDental ImplantsDental ArchIn Vitro TechniquesHumansComputer-Aided DesignMandibleModels, DentalDental Impression TechniqueBone ScrewsMouthPolymethyl Methacrylate

Substanzen

Dental ImplantsPolymethyl Methacrylate

Autor:innen und Institutionen

  • Professor, Department of Life Science, Health and Health Professions, Link Campus University, Rome, Italy.
  • Professor, Department of Clinical Science and Translational Medicine, University of Rome Tor Vergata, Rome, Italy; Adjunct Clinical Professor, Department of Periodontics and Oral Medicine, University of Michigan, Ann Ar…
  • Professor, Department of Restorative Sciences, Dental College of Georgia at Augusta University, Augusta, GA.
  • Professor, Department of Mathematics, University of Rome Tor Vergata, Rome, Italy.
  • Professor, Department of Odontostomatological and Maxillofacial Sciences, Sapienza University of Rome, Rome, Italy.

Förderung

  • Ministero dell’Istruzione, dell’Università e della Ricerca

Zitieren

APA

Arcuri, L., Pozzi, A., Londono, J., Nardi, A., Testarelli, L., & Galli, M. (2025). Complete arch digital implant scan accuracy with screw-retained or snap-on scan bodies: A comparative in vitro study. The Journal of Prosthetic Dentistry. https://doi.org/10.1016/j.prosdent.2025.04.003

Vancouver

Arcuri L, Pozzi A, Londono J, Nardi A, Testarelli L, Galli M. Complete arch digital implant scan accuracy with screw-retained or snap-on scan bodies: A comparative in vitro study. The Journal of Prosthetic Dentistry. 2025. doi:10.1016/j.prosdent.2025.04.003

BibTeX
@article{Arcuri2025,
  author = {Arcuri, Lorenzo and Pozzi, Alessandro and Londono, Jimmy and Nardi, Alessandra and Testarelli, Luca and Galli, Massimo},
  title = {Complete arch digital implant scan accuracy with screw-retained or snap-on scan bodies: A comparative in vitro study},
  journal = {The Journal of Prosthetic Dentistry},
  year = {2025},
  doi = {10.1016/j.prosdent.2025.04.003}
}
Kostenlos starten →