EUVIMEDEUVIMED entdecken
Crossref

Clinical evaluation of autonomous robotic‐assisted full‐arch implant surgery: A 1‐year prospective clinical study

Rui Xie iD, Yuchen Liu, Hongbo Wei, Tingmin Zhang, Shizhu Bai, Yimin Zhao

Clinical Oral Implants Research · 2024-04 · 35 (4) · 443-453

DOI: 10.1111/clr.14243 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Clinical Oral Implants Research, online erschienen am 06.02.2024. Verfasst von Rui Xie und 5 weiteren Autor:innen. Beteiligte Einrichtung: State Key Laboratory of Oral and Maxillofacial Reconstruction and Regeneration, Xi'an, Shaanxi, China. Hauptthemen laut MEDLINE: Dental Implants, Robotic Surgical Procedures, Surgery, Computer-Assisted. Die Arbeit wurde bisher 36-mal zitiert (Crossref) und nennt 28 Literaturangaben. Gefördert von: Nature and Science Basic Research Program of Shaanxi Province, State Key Laboratory of Oral & Maxillofacial Reconstruction and Regeneration.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

This prospective clinical study aimed to evaluate the accuracy and 1‐year clinical follow‐up performance of dental implant placement with an autonomous dental implant robot (ADIR) system in full‐arch implant surgery. Materials and Methods Twelve patients with edentulous arches or final dentition received 102 implants using the ADIR system. Global platform deviation, global apex deviation, and global angular deviation between the planned and actual implants were calculated after surgery. Data were statistically analyzed for factors including jaws, implant positions, patient sequences, implant systems, and implant length. Surgery duration was recorded. Patients were followed for 3 months and 1 year after surgery. Periodontal parameters, buccal bone thickness (BBT), and facial vertical bone wall peak (IP‐FC) were recorded.

Results

Among the 102 implants, the mean (SD) global platform deviation, global apex deviation, and global angular deviation were 0.53 (0.19) mm, 0.58 (0.17) mm, and 1.83 (0.82)°, respectively. The deviation differences between the mandible and maxilla did not show statistical significance ( p > .05). No statistically significant differences were found for the jaws, implant positions, patient sequences, implant systems, and implant length to the deviations ( p > .05). The periodontal parameters, the BBT, and IP‐FC remained stable during 1‐year follow‐up.

Conclusion

The ADIR system showed excellent positional accuracy. The 1‐year follow‐up after full‐arch implant surgery indicated that the ADIR system could achieve promising clinical performance. Additional clinical evidence is requisite to furnish guidelines for the implementation of the ADIR system in full‐arch implant surgery.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Dental ImplantsRobotic Surgical ProceduresSurgery, Computer-AssistedHumansDental Implantation, EndosseousProspective StudiesCone-Beam Computed TomographyComputer-Aided DesignImaging, Three-Dimensional

Stichwörter der Autor:innen

accuracybuccal bone thicknesscomputer‐assisted implant surgerydental implantssurgical robot

Substanzen

Dental Implants

Autor:innen und Institutionen

  • State Key Laboratory of Oral and Maxillofacial Reconstruction and Regeneration, Xi'an, Shaanxi, China.
  • National Clinical Research Center for Oral Diseases, Xi'an, Shaanxi, China.
  • Shaanxi Key Laboratory of Stomatology, Xi'an, Shaanxi, China.
  • Digital Center, School of Stomatology, The Fourth Military Medical University, Xi'an, Shaanxi, China.
  • Department of Oral Implants, School of Stomatology, The Fourth Military Medical University, Xi'an, Shaanxi, China.

ORCID-Profile: Rui Xie

Förderung

  • Nature and Science Basic Research Program of Shaanxi Province
  • State Key Laboratory of Oral & Maxillofacial Reconstruction and Regeneration

Zitieren

APA

Xie, R., Liu, Y., Wei, H., Zhang, T., Bai, S., & Zhao, Y. (2024). Clinical evaluation of autonomous robotic‐assisted full‐arch implant surgery: A 1‐year prospective clinical study. Clinical Oral Implants Research, 35(4), 443-453. https://doi.org/10.1111/clr.14243

Vancouver

Xie R, Liu Y, Wei H, Zhang T, Bai S, Zhao Y. Clinical evaluation of autonomous robotic‐assisted full‐arch implant surgery: A 1‐year prospective clinical study. Clinical Oral Implants Research. 2024;35(4):443-453. doi:10.1111/clr.14243

BibTeX
@article{Xie2024,
  author = {Xie, Rui and Liu, Yuchen and Wei, Hongbo and Zhang, Tingmin and Bai, Shizhu and Zhao, Yimin},
  title = {Clinical evaluation of autonomous robotic‐assisted full‐arch implant surgery: A 1‐year prospective clinical study},
  journal = {Clinical Oral Implants Research},
  year = {2024},
  volume = {35},
  number = {4},
  pages = {443--453},
  doi = {10.1111/clr.14243}
}
Infokarte | EUVIMED

Artikeldaten derzeit nicht verfügbar.

Recherche