Fachartikel in der Zeitschrift Clinical Oral Implants Research, 2024. Verfasst von Sihui Zhang und 6 weiteren Autor:innen. Beteiligte Einrichtung: Fujian Key Laboratory of Oral Diseases & Fujian Provincial Engineering Research Center of Oral Biomaterial & Stomatological Key Lab of Fujian College…. Hauptthemen laut MEDLINE: Dental Implants, Robotic Surgical Procedures, Surgery, Computer-Assisted. Die Arbeit wurde bisher 42-mal zitiert (Crossref) und nennt 32 Literaturangaben. Gefördert von: Fujian provincial health technology project.
Abstract (Originalsprache)
Objective
Optimal implant planning and placement allows the prosthesis to be well designed to achieve a satisfactory aesthetic and functional outcome. We aimed to compare deviations between implant planning and placement with the assistance of dynamic computer‐assisted implant surgery (d‐CAIS) or autonomous robotic computer‐assisted implant surgery (r‐CAIS) methods in a clinical setting.
Methods
The retrospective analysis of medical records between 2021 July and 2022 December was conducted to compare the implantation accuracy of the d‐CAIS and r‐CAIS system in partially edentulous patients through cone‐beam computed tomography. Patient‐reported outcomes (PROs) were recorded using a visual analogue scale (VAS). The Kolmogorov–Smirnov test was used to check the data distribution. Student's t ‐test or Mann–Whitney U ‐test was used as appropriate, with a defined significant difference ( p < .05).
Results
Seventy‐seven patients were analysed (124 implants), with 38 patients (62 implants) in the d‐CAIS group and 39 patients (62 implants) in the r‐CAIS group. The differences between d‐CAIS and r‐CAIS were 4.09 ± 1.79° versus 1.37 ± 0.92° ( p < .001) in angular deviation; 1.25 ± 0.54 versus 0.68 ± 0.36 mm ( p < .001) in coronal global deviation; 1.39 ± 0.52 versus 0.69 ± 0.36 mm ( p < .001) in apical global deviation; the results of the PROMs showed no statistical difference between the two groups. Conclusions r‐CAIS allows more accurate implant placement than the d‐CAIS technology. And both groups achieved overall satisfactory outcomes via VAS (Chinese Clinical Trial Registry ChiCTR2300072004).
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Fujian Key Laboratory of Oral Diseases & Fujian Provincial Engineering Research Center of Oral Biomaterial & Stomatological Key Lab of Fujian College and University, School and Hospital of Stomatology, Fujian Medical Un…
- Institute of Stomatology & Research Center of Dental and Craniofacial Implants, School and Hospital of Stomatology, Fujian Medical University, Fujian, PR China.
ORCID-Profile: Qin Cai, Yuxuan Lin
Förderung
- Fujian provincial health technology project
Zitieren
APA
Zhang, S., Cai, Q., Chen, W., Lin, Y., Gao, Y., Wu, D., & Chen, J. (2024). Accuracy of implant placement via dynamic navigation and autonomous robotic computer‐assisted implant surgery methods: A retrospective study. Clinical Oral Implants Research. https://doi.org/10.1111/clr.14216
Vancouver
Zhang S, Cai Q, Chen W, Lin Y, Gao Y, Wu D, et al. Accuracy of implant placement via dynamic navigation and autonomous robotic computer‐assisted implant surgery methods: A retrospective study. Clinical Oral Implants Research. 2024. doi:10.1111/clr.14216
BibTeX
@article{Zhang2024,
author = {Zhang, Sihui and Cai, Qin and Chen, Weiyi and Lin, Yuxuan and Gao, Yan and Wu, Dong and Chen, Jiang},
title = {Accuracy of implant placement via dynamic navigation and autonomous robotic computer‐assisted implant surgery methods: A retrospective study},
journal = {Clinical Oral Implants Research},
year = {2024},
doi = {10.1111/clr.14216}
}
EUVIMED