Accuracy of dental implant surgery with freehand, static computer-aided, dynamic computer-aided, and robotic computer-aided implant systems: An in vitro study

Wenbo Zhao, Weiwei Teng, Yucheng Su, Libo Zhou

The Journal of Prosthetic Dentistry · 2025

DOI: 10.1016/j.prosdent.2024.10.013 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift The Journal of Prosthetic Dentistry, 2025. Verfasst von Wenbo Zhao und 3 weiteren Autor:innen. Beteiligte Einrichtung: Graduate student, Stomatology College of Jiamusi University, Jiamusi, PR China. Hauptthemen laut MEDLINE: Surgery, Computer-Assisted, Dental Implants, Dental Implantation, Endosseous, Robotic Surgical Procedures. Die Arbeit wurde bisher 15-mal zitiert (Crossref) und nennt 36 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

STATEMENT OF PROBLEM: The static computer-aided implant system (S-CAIS), dynamic computer-aided implant system (D-CAIS), and robotic computer-aided implant system (R-CAIS) have been used to improve the accuracy of implant placement. However, the accuracy of freehand (FH),S-CAIS, D-CAIS, and R-CAIS implant placement has not been compared and verified under identical conditions. PURPOSE: The purpose of this in vitro study was to compare the accuracy of dental implant placement using S-CAIS, D-CAIS, R-CAIS, and FH techniques under identical conditions. MATERIAL AND METHODS: A total of 60 standardized polyurethane resin models with missing mandibular teeth were prepared and divided into 4 groups: FH, S-CAIS, D-CAIS, and R-CAIS, each consisting of 15 models. Preoperative implant planning was performed using cone beam computed tomography (CBCT), and 2 implants were placed in each model using the FH, S-CAIS, D-CAIS, and R-CAIS techniques, respectively. Postoperatively, CBCT scans were made for analysis of the entry, apical, and angle deviations. The error results among groups were compared using 1-way analysis of variance or a nonparametric test. The Dunnett test was used for post hoc comparison (α=.05). RESULTS: The mean ±standard deviation values for entry deviation were 1.09 ±0.33 mm for the FH group, 0.72 ±0.33 mm for S-CAIS, 0.69 ±0.29 mm for D-CAIS, and 0.48 ±0.18 mm for R-CAIS (P

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Surgery, Computer-AssistedDental ImplantsDental Implantation, EndosseousRobotic Surgical ProceduresHumansIn Vitro TechniquesCone-Beam Computed TomographyComputer-Aided DesignMandible

Substanzen

Dental Implants

Autor:innen und Institutionen

  • Graduate student, Stomatology College of Jiamusi University, Jiamusi, PR China.
  • Full Professor, Experimental Center for Stomatological Engineering, Jiamusi University & Key Laboratory of Oral Biomedical Materials and Clinical Application, Jiamusi, Heilongjiang Province, PR China; and Department of…
  • Full Professor, Department of Digital Dental Implant, Affliated Stomatological Hospital of Jiamusi University & Stomatology College of Jiamusi University, Jiamusi, Heilongjiang Province, PR China; and Experimental Cente…

Zitieren

APA

Zhao, W., Teng, W., Su, Y., & Zhou, L. (2025). Accuracy of dental implant surgery with freehand, static computer-aided, dynamic computer-aided, and robotic computer-aided implant systems: An in vitro study. The Journal of Prosthetic Dentistry. https://doi.org/10.1016/j.prosdent.2024.10.013

Vancouver

Zhao W, Teng W, Su Y, Zhou L. Accuracy of dental implant surgery with freehand, static computer-aided, dynamic computer-aided, and robotic computer-aided implant systems: An in vitro study. The Journal of Prosthetic Dentistry. 2025. doi:10.1016/j.prosdent.2024.10.013

BibTeX
@article{Zhao2025,
  author = {Zhao, Wenbo and Teng, Weiwei and Su, Yucheng and Zhou, Libo},
  title = {Accuracy of dental implant surgery with freehand, static computer-aided, dynamic computer-aided, and robotic computer-aided implant systems: An in vitro study},
  journal = {The Journal of Prosthetic Dentistry},
  year = {2025},
  doi = {10.1016/j.prosdent.2024.10.013}
}
Kostenlos starten →