Accuracy of autonomous robotic surgery for single-tooth implant placement: A case series
Journal of Dentistry · 2023-05 · 132 · 104451
DOI: 10.1016/j.jdent.2023.104451 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Dentistry, 2023-05. Verfasst von Shuo Yang und 5 weiteren Autor:innen. Beteiligte Einrichtung: Center of Oral Implantology, Stomatological Hospital, School of Stomatology, Southern Medical University, China. Hauptthemen laut MEDLINE: Dental Implants, Dental Implants, Single-Tooth, Robotic Surgical Procedures, Surgery, Computer-Assisted. Die Arbeit wurde bisher 106-mal zitiert (Crossref) und nennt 45 Literaturangaben.
Abstract (Originalsprache)
OBJECTIVES: This study aimed to investigate the accuracy of the autonomous robotic computer-assisted implant surgery (r-CAIS) for single-tooth implant placement. METHODS: Patients with a single missing tooth were enrolled for the autonomous robotic implant surgery. The patients underwent a cone-beam computed tomography (CBCT) scan with a positioning marker. Virtual preoperative implant placement and a drilling plan were created before surgery. The robotic system automatically performed the implant osteotomy and placement intraoperatively under the surgeon's supervision. A postoperative CBCT scan was performed to evaluate the deviations between the planned and placed implants. RESULTS: Ten patients with single dental implant placement were enrolled. No adverse surgical events and postoperative complications (i.e., infection and early implant failure) were reported. The autonomous robotic implant surgery exhibited a mean overall coronal deviation of 0.74 mm (95% CI: 0.53 to 0.94 mm), a mean overall apical deviation of 0.73 mm (95% CI: 0.53 to 0.93 mm), and an angular deviation of 1.11° (95% CI: 0.78 to 1.44°), respectively. CONCLUSIONS: The high accuracy of autonomous r-CAIS technology in single-tooth implant placement was attributed to the control of the angular deviation and axial errors. CLINICAL SIGNIFICANCE: The main findings of this study provide significant evidence to support the autonomous robotic implant surgery system as a potential alternative in dental implant surgery.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Center of Oral Implantology, Stomatological Hospital, School of Stomatology, Southern Medical University, China.
- Division of Periodontology and Implant Dentistry, Faculty of Dentistry, Prince Philip Dental Hospital, The University of Hong Kong, 34 Hospital Road, Hong Kong SAR 999077, China.
- Center of Oral Implantology, Stomatological Hospital, School of Stomatology, Southern Medical University, China. Electronic address: pingli_88@smu.edu.cn.
- Center of Oral Implantology, Stomatological Hospital, School of Stomatology, Southern Medical University, China. Electronic address: xushulan_672588@smu.edu.cn.
Zitieren
APA
Yang, S., Chen, J., Li, A., Deng, K., Li, P., & Xu, S. (2023). Accuracy of autonomous robotic surgery for single-tooth implant placement: A case series. Journal of Dentistry, 132, 104451. https://doi.org/10.1016/j.jdent.2023.104451
Vancouver
Yang S, Chen J, Li A, Deng K, Li P, Xu S. Accuracy of autonomous robotic surgery for single-tooth implant placement: A case series. Journal of Dentistry. 2023;132:104451. doi:10.1016/j.jdent.2023.104451
BibTeX
@article{Yang2023,
author = {Yang, Shuo and Chen, Jiahao and Li, An and Deng, Ke and Li, Ping and Xu, Shulan},
title = {Accuracy of autonomous robotic surgery for single-tooth implant placement: A case series},
journal = {Journal of Dentistry},
year = {2023},
volume = {132},
pages = {104451},
doi = {10.1016/j.jdent.2023.104451}
}
EUVIMED