Effect of implant shape and length on the accuracy of robot‐assisted immediate implant surgery: An in vitro study

Yunxiao Wang iD, Shimin Yu iD, Yulan Wang iD, Yi Feng iD, Qi Yan iD, Yufeng Zhang iD

Clinical Oral Implants Research · 2024

DOI: 10.1111/clr.14232 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Clinical Oral Implants Research, 2024. Verfasst von Yunxiao Wang und 5 weiteren Autor:innen. Beteiligte Einrichtung: State Key Laboratory of Oral and Maxillofacial Reconstruction and Regeneration, Key Laboratory of Oral Biomedicine Ministry of Education, Hubei Key L…. Hauptthemen laut MEDLINE: Dental Implants, Robotic Surgical Procedures, Robotics, Surgery, Computer-Assisted. Die Arbeit wurde bisher 16-mal zitiert (Crossref) und nennt 27 Literaturangaben. Gefördert von: Fundamental Research Funds for the Central Universities.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

To compare the accuracy of immediate implant placement of cylindrical implants (CI) and tapered implants (TI) of different lengths using a robotic dental implant system. Materials and Methods CI and TI of three lengths (8, 10, and 12 mm) each were digitally planned and placed in a three‐dimensional printed extraction socket model under robotic guidance. There were six groups with three samples in each group, resulting in a total of 18 samples. Implant angular deviation, platform point deviation (total, lateral, depth), and implant apical point deviation (total, lateral, depth) were recorded and compared between the different groups.

Results

The angular deviations for CI 8 mm, CI 10 mm, CI 12 mm, TI 8 mm, TI 10 mm, and TI 12 mm were 1.32° ± 0.19°, 1.03° ± 0.56°, 1.31° ± 0.38°, 1.27° ± 0.64°, 1.10° ± 0.43° and 1.05° ± 0.45°, respectively. The total deviations of platform and apical points for CI 8 mm, CI 10 mm, CI 12 mm, TI 8 mm, TI 10 mm, and TI 12 mm were 0.79 ± 0.18 mm, 0.77 ± 0.33 mm; 0.64 ± 0.21 mm, 0.55 ± 0.17 mm; 0.64 ± 0.37 mm, 0.65 ± 0.34 mm; 0.68 ± 0.26 mm, 0.71 ± 0.20 mm; 0.70 ± 0.12 mm, 0.66 ± 0.23 mm; and 0.71 ± 0.15 mm, 0.77 ± 0.29 mm, respectively, and had no significant differences.

Conclusions

Within the limitation of this study, acceptable accuracy can be achieved for both TI and CI using robotic systems. Our study demonstrated that the implant shape and length did not affect the accuracy of immediate implant placement under robotic guidance in vitro. However, further trials are required to confirm their efficacy in clinical practice.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Dental ImplantsRobotic Surgical ProceduresRoboticsSurgery, Computer-AssistedDental Implantation, EndosseousCone-Beam Computed TomographyComputer-Aided DesignImaging, Three-Dimensional

Stichwörter der Autor:innen

accuracycomputer-assisted implant surgerydental implantimmediate implant surgeryin vitro studyrobot-assisted surgery

Substanzen

Dental Implants

Autor:innen und Institutionen

  • State Key Laboratory of Oral and Maxillofacial Reconstruction and Regeneration, Key Laboratory of Oral Biomedicine Ministry of Education, Hubei Key Laboratory of Stomatology, School and Hospital of Stomatology, Wuhan Un…
  • Department of Oral Implantology, School and Hospital of Stomatology, Wuhan University, Wuhan, China.
  • Oral Biomaterials and Application Technology Engineering Research Center of Hubei Province, Wuhan, China.

ORCID-Profile: Yunxiao Wang, Shimin Yu, Yulan Wang, Yi Feng, Qi Yan, Yufeng Zhang

Förderung

  • Fundamental Research Funds for the Central Universities

Zitieren

APA

Wang, Y., Yu, S., Wang, Y., Feng, Y., Yan, Q., & Zhang, Y. (2024). Effect of implant shape and length on the accuracy of robot‐assisted immediate implant surgery: An in vitro study. Clinical Oral Implants Research. https://doi.org/10.1111/clr.14232

Vancouver

Wang Y, Yu S, Wang Y, Feng Y, Yan Q, Zhang Y. Effect of implant shape and length on the accuracy of robot‐assisted immediate implant surgery: An in vitro study. Clinical Oral Implants Research. 2024. doi:10.1111/clr.14232

BibTeX
@article{Wang2024,
  author = {Wang, Yunxiao and Yu, Shimin and Wang, Yulan and Feng, Yi and Yan, Qi and Zhang, Yufeng},
  title = {Effect of implant shape and length on the accuracy of robot‐assisted immediate implant surgery: An in vitro study},
  journal = {Clinical Oral Implants Research},
  year = {2024},
  doi = {10.1111/clr.14232}
}
Infokarte | EUVIMED

Artikeldaten derzeit nicht verfügbar.

Recherche