Influence of Different Protocols of Cone‐Beam Computed Tomography Units of High and Low Resolution on the Identification of Root Fractures
Australian Endodontic Journal · 2025
DOI: 10.1111/aej.12945 ↗At a glance
Journal article in Australian Endodontic Journal, 2025. Written by Érica Pozo Mautone and 6 co-authors. Institution: The Postgraduate Program in Health Sciences, University of Caxias Do Sul, Caxias do Sul, RS, Brazil. Major MEDLINE topics: Cone-Beam Computed Tomography, Tooth Fractures, Tooth Root. Cited 1 times so far (Crossref); 28 references.
Abstract (original language)
The aim of this study was to determine the efficacy of different protocols of cone beam computed tomography units with image resolutions for identifying dental root fractures. Accordingly, 24 single‐rooted teeth were endodontically prepared using gutta‐percha, fibreglass, or metal. Root fractures were caused in 50% of the samples. The teeth were included in a dry jaw and scanned using two tomographic units: OP300 and 3D Veraview. These tomographs respectively achieved an accuracy of 0.88 and 0.83 and a sensitivity of 0.78 and 0.83. The OP300 Maxio device had a high specificity of 0.98 compared to the 3D Veraview 's 0.83. Thus, the two devices tested were both adequate for the identification of root fractures. However, the 3D Veraview demonstrated greater accuracy in the detection of root fractures in roots containing metal posts, while the OP300 showed greater accuracy with the use of fibreglass posts. The presence of gutta‐percha compromised the identification of fractures with both devices.
Subjects
MeSH terms (MEDLINE)
Author keywords
Substances
Authors and institutions
- The Postgraduate Program in Health Sciences, University of Caxias Do Sul, Caxias do Sul, RS, Brazil.
- Independent Researcher, Farroupilha, RS, Brazil.
- The Federal Institute of Education, Science and Technology of Rio Grande Do Sul-Caxias Do Sul Campus, Caxias do Sul, RS, Brazil.
- Surgery and Orthopedics Department, Dental School, Federal University of Rio Grande Do Sul (UFRGS), Porto Alegre, RS, Brazil.
ORCID profiles: Thiago Oliveira Gamba
Cite
APA
Mautone, É. P., Zechin, J. G., Zorzi, J. E., Thomazi, E., Torriani, R., Gamba, T. O., & Perottoni, C. A. (2025). Influence of Different Protocols of Cone‐Beam Computed Tomography Units of High and Low Resolution on the Identification of Root Fractures. Australian Endodontic Journal. https://doi.org/10.1111/aej.12945
Vancouver
Mautone ÉP, Zechin JG, Zorzi JE, Thomazi E, Torriani R, Gamba TO, et al. Influence of Different Protocols of Cone‐Beam Computed Tomography Units of High and Low Resolution on the Identification of Root Fractures. Australian Endodontic Journal. 2025. doi:10.1111/aej.12945
BibTeX
@article{Mautone2025,
author = {Mautone, Érica Pozo and Zechin, Janaína Guzzo and Zorzi, Janete Eunice and Thomazi, Eduardo and Torriani, Rodrigo and Gamba, Thiago Oliveira and Perottoni, Claudio Antônio},
title = {Influence of Different Protocols of Cone‐Beam Computed Tomography Units of High and Low Resolution on the Identification of Root Fractures},
journal = {Australian Endodontic Journal},
year = {2025},
doi = {10.1111/aej.12945}
}
EUVIMED