EUVIMEDObjevte EUVIMED
Crossref

Influence of Different Protocols of Cone‐Beam Computed Tomography Units of High and Low Resolution on the Identification of Root Fractures

Érica Pozo Mautone, Janaína Guzzo Zechin, Janete Eunice Zorzi, Eduardo Thomazi, Rodrigo Torriani, Thiago Oliveira Gamba iD, Claudio Antônio Perottoni

Australian Endodontic Journal · 2025

DOI: 10.1111/aej.12945 ↗

At a glance

Journal article in Australian Endodontic Journal, 2025. Written by Érica Pozo Mautone and 6 co-authors. Institution: The Postgraduate Program in Health Sciences, University of Caxias Do Sul, Caxias do Sul, RS, Brazil. Major MEDLINE topics: Cone-Beam Computed Tomography, Tooth Fractures, Tooth Root. Cited 1 times so far (Crossref); 28 references.

AbstraktSubjectsBibliografické údajeCiteRelated studies

Abstract (original language)

The aim of this study was to determine the efficacy of different protocols of cone beam computed tomography units with image resolutions for identifying dental root fractures. Accordingly, 24 single‐rooted teeth were endodontically prepared using gutta‐percha, fibreglass, or metal. Root fractures were caused in 50% of the samples. The teeth were included in a dry jaw and scanned using two tomographic units: OP300 and 3D Veraview. These tomographs respectively achieved an accuracy of 0.88 and 0.83 and a sensitivity of 0.78 and 0.83. The OP300 Maxio device had a high specificity of 0.98 compared to the 3D Veraview 's 0.83. Thus, the two devices tested were both adequate for the identification of root fractures. However, the 3D Veraview demonstrated greater accuracy in the detection of root fractures in roots containing metal posts, while the OP300 showed greater accuracy with the use of fibreglass posts. The presence of gutta‐percha compromised the identification of fractures with both devices.

Subjects

MeSH terms (MEDLINE)

Cone-Beam Computed TomographyTooth FracturesTooth RootHumansGutta-PerchaSensitivity and Specificity

Author keywords

cone beam computed tomographyfibreglassgutta‐perchametalstooth fracture

Substances

Gutta-Percha

Authors and institutions

  • The Postgraduate Program in Health Sciences, University of Caxias Do Sul, Caxias do Sul, RS, Brazil.
  • Independent Researcher, Farroupilha, RS, Brazil.
  • The Federal Institute of Education, Science and Technology of Rio Grande Do Sul-Caxias Do Sul Campus, Caxias do Sul, RS, Brazil.
  • Surgery and Orthopedics Department, Dental School, Federal University of Rio Grande Do Sul (UFRGS), Porto Alegre, RS, Brazil.

ORCID profiles: Thiago Oliveira Gamba

Cite

APA

Mautone, É. P., Zechin, J. G., Zorzi, J. E., Thomazi, E., Torriani, R., Gamba, T. O., & Perottoni, C. A. (2025). Influence of Different Protocols of Cone‐Beam Computed Tomography Units of High and Low Resolution on the Identification of Root Fractures. Australian Endodontic Journal. https://doi.org/10.1111/aej.12945

Vancouver

Mautone ÉP, Zechin JG, Zorzi JE, Thomazi E, Torriani R, Gamba TO, et al. Influence of Different Protocols of Cone‐Beam Computed Tomography Units of High and Low Resolution on the Identification of Root Fractures. Australian Endodontic Journal. 2025. doi:10.1111/aej.12945

BibTeX
@article{Mautone2025,
  author = {Mautone, Érica Pozo and Zechin, Janaína Guzzo and Zorzi, Janete Eunice and Thomazi, Eduardo and Torriani, Rodrigo and Gamba, Thiago Oliveira and Perottoni, Claudio Antônio},
  title = {Influence of Different Protocols of Cone‐Beam Computed Tomography Units of High and Low Resolution on the Identification of Root Fractures},
  journal = {Australian Endodontic Journal},
  year = {2025},
  doi = {10.1111/aej.12945}
}
Start for free →