EUVIMEDEUVIMED entdecken
Crossref

Impact of CBCT acquisition protocols and artifact reduction filters on diagnosing vertical root fractures

Eduarda Adams Hilgert, Gabriela Salatino Liedke iD, Priscila Fernanda da Silveira Tiecher, Nádia Assein Arus, Thiago de Oliveira Gamba iD, Heraldo Luis Dias da Silveira, Mariana Boessio Vizzotto

Dental Traumatology · 2025

DOI: 10.1111/edt.12984 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Dental Traumatology, 2025. Verfasst von Eduarda Adams Hilgert und 6 weiteren Autor:innen. Beteiligte Einrichtung: School of Dentistry, Surgery and Orthopedics Department, Universidade Federal do Rio Grande do Sul (UFRGS), Porto Alegre, Rio Grande do Sul, Brazil. Hauptthemen laut MEDLINE: Tooth Fractures, Cone-Beam Computed Tomography, Tooth Root, Artifacts. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 20 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Aim

To evaluate the impact of acquisition protocols and artifact reduction filters in cone beam computed tomography on diagnosing vertical root fractures in endodontically treated teeth with and without intraradicular posts. Materials and Methods We analyzed 480 tomographic images acquired from two J. Morita scanners (0.125‐ and 0.08‐mm voxel sizes protocols), with application of a blooming artifact reduction filter. Three evaluators assessed these images for root fractures using a 5‐point Likert scale. Diagnostic accuracy between filters and protocols was determined using generalized linear models with binomial distribution for the outcome, considering protocol, filter, and dental status. Sensitivity, specificity, positive predictive value, and negative predictive value were also estimated for the filters and protocols.

Results

The 0.08‐mm voxel size protocol demonstrated a significantly higher percentage of accurate diagnosis compared to the 0.125‐mm protocol ( p = .001). No statistically significant differences ( p ≥ .087) were observed for filter application, interaction between protocol and filter, or dental status. Accuracy, sensitivity, and specificity values were respectively: .93, .87, 1.00 (protocol 1); .99, .99, .99 (protocol 2); .98, .96, .99 (no filter); .95, .90, 1.00 (with filter).

Conclusion

The new findings found for the two J Morita scanners used in our study were that images acquired using the voxel size of 0.08 mm showed an improvement in the diagnosis of root fractures and the filters in these devices have no relevance significant for the diagnosis.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Tooth FracturesCone-Beam Computed TomographyTooth RootArtifactsHumansSensitivity and SpecificityFemaleMaleTooth, NonvitalAdult

Stichwörter der Autor:innen

artifactscone‐beam computed tomographyendodontics

Autor:innen und Institutionen

  • School of Dentistry, Surgery and Orthopedics Department, Universidade Federal do Rio Grande do Sul (UFRGS), Porto Alegre, Rio Grande do Sul, Brazil.
  • School of Dentistry, Stomatology Department, Universidade Federal de Santa Maria (UFSM), Santa Maria, Rio Grande do Sul, Brazil.

ORCID-Profile: Gabriela Salatino Liedke, Thiago de Oliveira Gamba

Zitieren

APA

Hilgert, E. A., Liedke, G. S., da Silveira Tiecher, P. F., Arus, N. A., de Oliveira Gamba, T., da Silveira, H. L. D., & Vizzotto, M. B. (2025). Impact of CBCT acquisition protocols and artifact reduction filters on diagnosing vertical root fractures. Dental Traumatology. https://doi.org/10.1111/edt.12984

Vancouver

Hilgert EA, Liedke GS, da Silveira Tiecher PF, Arus NA, de Oliveira Gamba T, da Silveira HLD, et al. Impact of CBCT acquisition protocols and artifact reduction filters on diagnosing vertical root fractures. Dental Traumatology. 2025. doi:10.1111/edt.12984

BibTeX
@article{Hilgert2025,
  author = {Hilgert, Eduarda Adams and Liedke, Gabriela Salatino and da Silveira Tiecher, Priscila Fernanda and Arus, Nádia Assein and de Oliveira Gamba, Thiago and da Silveira, Heraldo Luis Dias and Vizzotto, Mariana Boessio},
  title = {Impact of CBCT acquisition protocols and artifact reduction filters on diagnosing vertical root fractures},
  journal = {Dental Traumatology},
  year = {2025},
  doi = {10.1111/edt.12984}
}
Kostenlos starten →