High-Performance Dual-Ended SiPM Readout for TOF-PET With BGO and LYSO:Ce
IEEE Transactions on Radiation and Plasma Medical Sciences · 2025-07 · 9 (6) · 721-735
DOI: 10.1109/trpms.2025.3539191 ↗Kurz gefasst
Fachartikel in der Zeitschrift IEEE Transactions on Radiation and Plasma Medical Sciences, 2025-07. Verfasst von Nicolaus Kratochwil und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedical Engineering, University of California at Davis (UCD), Davis, CA, United States. Die Arbeit wurde bisher 15-mal zitiert (Crossref) und nennt 51 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: NIBIB NIH HHS, National Institute of Health, (PI Cates).
Abstract (Originalsprache)
Detection time performance is a key aspect for time-of-flight positron emission tomography. With recent advancement in SiPM technology and fast readout electronics, one limiting factor on timing performance is light transport in the crystal. For high aspect-ratio crystals with single-ended readout, the time information of approximately half the optical photons is severely degraded as they initially travel in the direction opposed to the photodetector. For promptly-emitted Cherenkov photons, the increase of variance of optical path length limits their intrinsic advantage. Low-noise and high-frequency dual-ended SiPM readout can be employed to mitigate the aforementioned challenges and has the potential to combine ultra-fast timing with highest gamma-ray detection efficiency. We have studied the timing properties of cerium-doped lutetium-yttrium-oxyorthosilicate (LYSO:Ce) and bismuth germanate (BGO) in a symmetric dual-ended SiPM readout configuration. A time-based depth-of-interaction correction and a novel adaptive timestamp weighting was used to optimize the timing performance. Coupling 3×3×20 mm3 polished BGO crystals to Broadcom AFBR-S4N44P014M SiPMs a CTR of 234 ± 4 ps FWHM (harmonic average) was obtained for all photopeak events. For same-sized LYSO:Ce crystals, the measured CTR value is 98 ± 2 ps, which is in excellent agreement with analytic calculations on the timing limits considering scintillation properties and modeling of light transport. The results demonstrate significant timing improvement with dual-ended readout, both for Cherenkov photons in BGO and for standard scintillation for enhanced diagnostic accuracy in PET imaging.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Biomedical Engineering, University of California at Davis (UCD), Davis, CA, United States.
- Department of Biomedical Engineering and with the Department of Radiology at UCD.
- Lawrence Berkeley National Laboratory, Berkeley, CA, United States.
- Department of Biomedical Engineering at UCD and with the Institut de Física d'Altes Energies - Barcelona Institute of Science and Technology, Bellaterra, Barcelona, Spain.
ORCID-Profile: Nicolaus Kratochwil, Emilie Roncali, Joshua W Cates, Gerard Ariño-Estrada
Förderung
- NIBIB NIH HHS
- National Institute of Health
- (PI Cates)
Zitieren
APA
Kratochwil, N., Roncali, E., Cates, J. W., & Ariño-Estrada, G. (2025). High-Performance Dual-Ended SiPM Readout for TOF-PET With BGO and LYSO:Ce. IEEE Transactions on Radiation and Plasma Medical Sciences, 9(6), 721-735. https://doi.org/10.1109/trpms.2025.3539191
Vancouver
Kratochwil N, Roncali E, Cates JW, Ariño-Estrada G. High-Performance Dual-Ended SiPM Readout for TOF-PET With BGO and LYSO:Ce. IEEE Transactions on Radiation and Plasma Medical Sciences. 2025;9(6):721-735. doi:10.1109/trpms.2025.3539191
BibTeX
@article{Kratochwil2025,
author = {Kratochwil, Nicolaus and Roncali, Emilie and Cates, Joshua W and Ariño-Estrada, Gerard},
title = {High-Performance Dual-Ended SiPM Readout for TOF-PET With BGO and LYSO:Ce},
journal = {IEEE Transactions on Radiation and Plasma Medical Sciences},
year = {2025},
volume = {9},
number = {6},
pages = {721--735},
doi = {10.1109/trpms.2025.3539191}
}
EUVIMED