Beam-width-corrected DOI resolution measurement of dual-ended readout PET detectors
Physics in Medicine & Biology · 14.11.2026 · 71 (21) · 215036
DOI: 10.1088/1361-6560/aebd34 ↗Kurz gefasst
Fachartikel in der Zeitschrift Physics in Medicine & Biology, online erschienen am 13.11.2026. Verfasst von Hui Huang und 7 weiteren Autor:innen. Beteiligte Einrichtung: Southern University of Science and Technology, Shenzhen, People's Republic of China. Hauptthemen laut MEDLINE: Positron-Emission Tomography. Die Arbeit nennt 31 Literaturangaben. Gefördert von: Basic and Applied Basic Research Foundation of Guangdong Province, Shenzhen Science and Technology Program, National Natural Science Foundation of China.
Abstract (Originalsprache)
Objective. Dual-ended readout PET detectors provide depth-of-interaction (DOI) information for reducing parallax errors in high-resolution PET imaging. This study compared LYSO detectors with different inter-crystal reflectors and investigated the effect of irradiation beam width on DOI resolution measurements under electronic collimation. Approach. Two 28 × 28 LYSO arrays with 0.75 × 0.75 × 10 mm 3 crystals and BaSO 4 or E60 reflectors were characterized in terms of flood-map quality, energy resolution, and DOI resolution. Part of E60 detector (8 × 8 crystals) was further measured using three irradiation geometries with beam widths of 0.80 mm, 0.62 mm, and 0.46 mm. A beam-width correction was applied to the measured DOI resolution, and the effects of energy selection and empirical flood-map-based inter-crystal scattering (ICS) filtering were evaluated. Main results. The BaSO 4 detector showed better flood-map quality and energy resolution, whereas the E60 detector showed better DOI resolution. In the 400–650 keV energy window, the measured average DOI resolutions of entire 28 × 28 LYSO pixels with irradiation beam width of 1.00 mm were 1.92 and 1.75 mm for the BaSO 4 and E60 detectors, respectively. For the selected 8 × 8 crystal region of the E60 detector, the corrected DOI resolution by subtracting the irradiation beam width improved from 1.19 mm for all events to 1.01 mm after energy selection, and further to 0.86 mm after additional empirical flood-map-based ICS filtering. Significance. Irradiation beam width introduces a geometry-dependent contribution to DOI resolution measurements. Beam-width correction enables more consistent DOI characterization under different irradiation geometries.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Southern University of Science and Technology, Shenzhen, People's Republic of China.
- Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, People's Republic of China.
- Biomedical Imaging Science and System Key Laboratory, Chinese Academy of Sciences, 518055 Shenzhen, People's Republic of China.
ORCID-Profile: Hui Huang, Zhonghua Kuang, Yongfeng Yang, Zheng Liu
Förderung
- Basic and Applied Basic Research Foundation of Guangdong Province
- Shenzhen Science and Technology Program
- National Natural Science Foundation of China
- National Key Research and Development Program of China
Zitieren
APA
Huang, H., Hou, G., Li, H., Yang, S., Kuang, Z., Ren, N., Yang, Y., & Liu, Z. (2026). Beam-width-corrected DOI resolution measurement of dual-ended readout PET detectors. Physics in Medicine & Biology, 71(21), 215036. https://doi.org/10.1088/1361-6560/aebd34
Vancouver
Huang H, Hou G, Li H, Yang S, Kuang Z, Ren N, et al. Beam-width-corrected DOI resolution measurement of dual-ended readout PET detectors. Physics in Medicine & Biology. 2026;71(21):215036. doi:10.1088/1361-6560/aebd34
BibTeX
@article{Huang2026,
author = {Huang, Hui and Hou, Gangxin and Li, Haonan and Yang, Sen and Kuang, Zhonghua and Ren, Ning and Yang, Yongfeng and Liu, Zheng},
title = {Beam-width-corrected DOI resolution measurement of dual-ended readout PET detectors},
journal = {Physics in Medicine & Biology},
year = {2026},
volume = {71},
number = {21},
pages = {215036},
doi = {10.1088/1361-6560/aebd34}
}