EUVIMEDEUVIMED entdecken
Open Access

Development of Whole-Body TOF-DOI PET Detector Using Dual-Ended Readout Method

Haibo Wang, Jiahao Xie, Junwei Du

IEEE Transactions on Instrumentation and Measurement · 2025 · 74 · 1-9

DOI: 10.1109/tim.2025.3570343 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Transactions on Instrumentation and Measurement, 2025. Verfasst von Haibo Wang und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedical Engineering, University of California at Davis, Davis, CA 95616, USA. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 58 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NIBIB NIH HHS, National Institutes of Health.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Positron emission tomography (PET) is the most sensitive in vivo molecular instrumentation. The image quality of PET can be significantly enhanced by incorporating time-of-flight (TOF) and depth-of-interaction (DOI) information. In this study, whole-body TOF-DOI PET detectors based on the dual-ended readout method were developed to simultaneously provide good TOF and DOI information. Each detector consisted of two 8 × 8 Hamamatsu S14161-3050-08 silicon photomultiplier (SiPM) arrays coupled to both ends of an 8 × 8 lutetium-yttrium oxyorthosilicate (LYSO) array with a thickness of 20 mm. Both the LYSO and SiPM arrays had a pitch of 3.2 mm, allowing each LYSO element to be coupled to two SiPM elements, one at each end of the crystal, to achieve the optimal timing resolution. Experimental results demonstrated that the detectors achieved a coincidence timing resolution of 234 ± 7 ps, an energy resolution of 13.7 ± 2.0%, and a DOI resolution of 2.6 ± 0.2 mm. These results suggest that the developed detectors are suitable for constructing whole-body TOF-DOI PET scanners with uniform spatial resolution across the entire field-of-view.

Schlagwörter

Stichwörter der Autor:innen

Positron emission tomography (PET)coincidence timing resolution (CTR)depth-of-interaction (DOI)dual-ended readouttime-of-flight (TOF)

Autor:innen und Institutionen

  • Department of Biomedical Engineering, University of California at Davis, Davis, CA 95616, USA.

Förderung

  • NIBIB NIH HHS
  • National Institutes of Health

Zitieren

APA

Wang, H., Xie, J., & Du, J. (2025). Development of Whole-Body TOF-DOI PET Detector Using Dual-Ended Readout Method. IEEE Transactions on Instrumentation and Measurement, 74, 1-9. https://doi.org/10.1109/tim.2025.3570343

Vancouver

Wang H, Xie J, Du J. Development of Whole-Body TOF-DOI PET Detector Using Dual-Ended Readout Method. IEEE Transactions on Instrumentation and Measurement. 2025;74:1-9. doi:10.1109/tim.2025.3570343

BibTeX
@article{Wang2025,
  author = {Wang, Haibo and Xie, Jiahao and Du, Junwei},
  title = {Development of Whole-Body TOF-DOI PET Detector Using Dual-Ended Readout Method},
  journal = {IEEE Transactions on Instrumentation and Measurement},
  year = {2025},
  volume = {74},
  pages = {1--9},
  doi = {10.1109/tim.2025.3570343}
}
Kostenlos starten →