Improving CTR With the FastIC ASIC for TOF-PET by Overcoming SiPM Noise With Baseline Correction

Afonso Silvério Xavier De Matos Pinto iD, Nicolaus Kratochwil iD, Sergio Gómez iD, David Gascón iD, Pedro Correia iD, João Veloso iD, Emilie Roncali iD, Ana Luísa Silva iD, Gerard Ariño-Estrada iD

IEEE Transactions on Radiation and Plasma Medical Sciences · 2025-09 · 9 (7) · 857-865

DOI: 10.1109/trpms.2025.3532794 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Transactions on Radiation and Plasma Medical Sciences, 2025-09. Verfasst von Afonso Silvério Xavier De Matos Pinto und 8 weiteren Autor:innen. Beteiligte Einrichtung: I3N Physics Department (I3N) at the University of Aveiro, Portugal. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 32 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NIBIB NIH HHS, PI Ariño-Estrada, Prototera.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Time resolution in time-of-flight positron emission tomography (TOF-PET) has improved significantly over the last decade due to advancements in scintillation materials, photodetectors, and readout electronics, which has increased the signal-to-noise ratio (SNR) compared to conventional PET. Silicon photomultipliers (SiPMs) in TOF-PET detectors are often operated at high bias voltage to improve the time performance at the expense of increasing signal noise. SiPM noise, both correlated and uncorrelated, can cause baseline fluctuations, leading to time-walk effects when a leading edge trigger strategy is used, and thus limiting timing performance. We examined the effect of SiPM baseline fluctuations using the FastIC ASIC, a scalable multichannel readout for fast timing applications. We flagged noisy events by using a comparator signal triggered by dark counts before the actual scintillation event. We tested different classification and correction methods with scintillating crystals and Cherenkov radiators, coupled to analog SiPMs from Broadcom (NUV-MT) and Hamamatsu Photonics. We reduced the coincidence time resolution (CTR) in bismuth germanate 2×2×3 mm3 (BGO) crystals from 410 ± 10 ps to 388 ± 10 ps FWHM (5 %) by correcting the time-walk on the noisy events. We measured an improvement from 107 ±2 ps to 93.5 ± 0.6 ps (11 %) for LYSO 2×2×3 mm3 crystals by filtering the noisy events. An improvement of 9 % on the CTR of the EJ232 plastic scintillator was also achieved by filtering noisy events, reducing it from 82.2 ± 0.5 ps to 75 ± 1 ps. This study presents a scalable method for flagging undesired events in a full TOF-PET system and discusses the impact of SiPM noise on the FastIC readout.

Autor:innen und Institutionen

  • I3N Physics Department (I3N) at the University of Aveiro, Portugal.
  • Department of Biomedical Engineering at UCD.
  • Serra Hunter fellow at Polytechnic University of Catalonia, Spain.
  • Department of Fisica at the University of Barcelona, Spain.
  • Institut de Física d'Altes Energies - Barcelona Institute of Science and Technology, Bellaterra, Barcelona, Spain.

ORCID-Profile: Afonso Silvério Xavier De Matos Pinto, Nicolaus Kratochwil, Sergio Gómez, David Gascón, Pedro Correia, João Veloso, Emilie Roncali, Ana Luísa Silva, Gerard Ariño-Estrada

Förderung

  • NIBIB NIH HHS
  • PI Ariño-Estrada
  • Prototera
  • i3N
  • National Funds through the FCT and Ministério da Educação e Cultura (MEC), Portugal
  • National Funds through the FCT, Portugal

Zitieren

APA

De Matos Pinto, A. S. X., Kratochwil, N., Gómez, S., Gascón, D., Correia, P., Veloso, J., Roncali, E., Silva, A. L., & Ariño-Estrada, G. (2025). Improving CTR With the FastIC ASIC for TOF-PET by Overcoming SiPM Noise With Baseline Correction. IEEE Transactions on Radiation and Plasma Medical Sciences, 9(7), 857-865. https://doi.org/10.1109/trpms.2025.3532794

Vancouver

De Matos Pinto ASX, Kratochwil N, Gómez S, Gascón D, Correia P, Veloso J, et al. Improving CTR With the FastIC ASIC for TOF-PET by Overcoming SiPM Noise With Baseline Correction. IEEE Transactions on Radiation and Plasma Medical Sciences. 2025;9(7):857-865. doi:10.1109/trpms.2025.3532794

BibTeX
@article{DeMatosPinto2025,
  author = {De Matos Pinto, Afonso Silvério Xavier and Kratochwil, Nicolaus and Gómez, Sergio and Gascón, David and Correia, Pedro and Veloso, João and Roncali, Emilie and Silva, Ana Luísa and Ariño-Estrada, Gerard},
  title = {Improving CTR With the FastIC ASIC for TOF-PET by Overcoming SiPM Noise With Baseline Correction},
  journal = {IEEE Transactions on Radiation and Plasma Medical Sciences},
  year = {2025},
  volume = {9},
  number = {7},
  pages = {857--865},
  doi = {10.1109/trpms.2025.3532794}
}
Kostenlos starten →