EUVIMEDEUVIMED entdecken
Crossref

Optical performance studies of an all-polymer air-core scintillation dosemeter for brachytherapy

Nor El Houda Boughaba, Boualem Bouzid, Nadia Yahlali

Radiation Protection Dosimetry · 2026

DOI: 10.1093/rpd/ncaf147 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Radiation Protection Dosimetry, 2026. Verfasst von Nor El Houda Boughaba und 2 weiteren Autor:innen. Beteiligte Einrichtung: SNIRM Laboratory, university of Science and Technology Houari Boumediene (USTHB), Bab-Ezzouar, BP 32 El Alia, 1611 Algiers, Algeria. Hauptthemen laut MEDLINE: Brachytherapy, Scintillation Counting, Polymers, Radiation Dosimeters. Die Arbeit nennt 9 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Plastic scintillation dosemeters have gained significant interest for invivo dosimetry in high-dose rate brachytherapy (BT) due to their favourable dosimetric properties. However, their clinical utility is limited by Cerenkov radiation, which can contribute over 50% of the signal, depending on the source position. The current dosemeter based on silica air-core (AC) light-guide was proven to be highly accurate; however, its high light loss and its mechanical rigidity limit its use for invivo BT dosimetry with flexible applicators. In the present work, a novel flexible all-polymer dosemeter with silver-coated polytetrafluoroethylene (Ag-PTFE) light-guide was built and compared to a solid-core light-guide dosemeter (standard dosemeter), using Geant4 Application for Tomographic Emission simulations. A reduction of the Cerenkov noise in the signal of this AC dosemeter was found below 0.3%, independently of the source position. On the other hand, the light collection efficiency was found to be $\sim $40% smaller than in the standard dosemeter. We show how it is possible to further reduce this difference to $\sim $20% and discuss the optimal design of this all-polymer Cerenkov-free dosemeter.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

BrachytherapyScintillation CountingPolymersRadiation DosimetersRadiometryEquipment DesignHumansPolytetrafluoroethyleneRadiotherapy DosageAirSilver

Substanzen

PolytetrafluoroethylenePolymersSilver

Autor:innen und Institutionen

  • SNIRM Laboratory, university of Science and Technology Houari Boumediene (USTHB), Bab-Ezzouar, BP 32 El Alia, 1611 Algiers, Algeria.
  • Instituto de Física Corpuscular, Centro mixto CSIC-Universidad de Valencia, C/Catedrático José Beltrán 2, E-46980 Paterna, Valencia, Spain.

Zitieren

APA

Boughaba, N. E. H., Bouzid, B., & Yahlali, N. (2026). Optical performance studies of an all-polymer air-core scintillation dosemeter for brachytherapy. Radiation Protection Dosimetry. https://doi.org/10.1093/rpd/ncaf147

Vancouver

Boughaba NEH, Bouzid B, Yahlali N. Optical performance studies of an all-polymer air-core scintillation dosemeter for brachytherapy. Radiation Protection Dosimetry. 2026. doi:10.1093/rpd/ncaf147

BibTeX
@article{Boughaba2026,
  author = {Boughaba, Nor El Houda and Bouzid, Boualem and Yahlali, Nadia},
  title = {Optical performance studies of an all-polymer air-core scintillation dosemeter for brachytherapy},
  journal = {Radiation Protection Dosimetry},
  year = {2026},
  doi = {10.1093/rpd/ncaf147}
}
Kostenlos starten →