EUVIMEDEUVIMED entdecken
Crossref

Study of the typical mixed radiation field induced by the beam loss in CSNS linac tunnel

Ze-Qi Huang iD, Han-Tao Jing, Qing-Biao Wu, Qi-Fan Dong, Zhi-Ping Li, Lun Li, Nikolaos Vassilopoulos, Yu-Liang Zhang

Radiation Protection Dosimetry · 2026

DOI: 10.1093/rpd/ncaf131 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Radiation Protection Dosimetry, 2026. Verfasst von Ze-Qi Huang und 7 weiteren Autor:innen. Beteiligte Einrichtung: Institute of High Energy Physics (IHEP), Chinese Academy of Sciences (CAS), 19B Yuquan Road, Shijingshan District, Beijing 100049, China. Hauptthemen laut MEDLINE: Particle Accelerators, Neutrons, Radiation Monitoring, Electronics. Die Arbeit nennt 25 Literaturangaben. Gefördert von: National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In recent years, more and more electronics have been exposed to the mixed radiation field. The radiation resistance of electronics has been paid more and more attention to and the China Spallation Neutron Source (CSNS) linac tunnel provides a natural mixed radiation field. One of the radiation hotspots induced by beam loss when the CSNS linac regularly operates is the debuncher component in the beamline. The radiation level around the debuncher was measured by dose monitors and simulated by the FLUKA code simultaneously. The results of measurement and simulation are consistent, which means that the model simulated by the FLUKA code is consistent with the actual situation. The energy spectrum of the mixed radiation field at CSNS was first simulated by the FLUKA code. The mixed radiation field is composed of charged and neutral hadrons (protons and neutrons), photons, and electrons over a range of energies. This radiation field is suitable for the radiation damage effect tests of electronic components operating in the mixed radiation environment, especially for the electronic components used in the accelerator tunnel.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Particle AcceleratorsNeutronsRadiation MonitoringElectronicsRadiation DosageComputer SimulationElectronsPhotonsChinaEquipment DesignMonte Carlo MethodProtons

Substanzen

Protons

Autor:innen und Institutionen

  • Institute of High Energy Physics (IHEP), Chinese Academy of Sciences (CAS), 19B Yuquan Road, Shijingshan District, Beijing 100049, China.
  • Spallation Neutron Source Science Center, 1 Zhongziyuan Road, Songshanhu district, Dongguan 523803, Guangdong, China.
  • University of Chinese Academy of Sciences (UCAS), No. 1 Yanqihu East Rd, Huairou District, Beijing 101408, China.

ORCID-Profile: Ze-Qi Huang

Förderung

  • National Natural Science Foundation of China

Zitieren

APA

Huang, Z. Q., Jing, H. T., Wu, Q. B., Dong, Q. F., Li, Z. P., Li, L., Vassilopoulos, N., & Zhang, Y. L. (2026). Study of the typical mixed radiation field induced by the beam loss in CSNS linac tunnel. Radiation Protection Dosimetry. https://doi.org/10.1093/rpd/ncaf131

Vancouver

Huang ZQ, Jing HT, Wu QB, Dong QF, Li ZP, Li L, et al. Study of the typical mixed radiation field induced by the beam loss in CSNS linac tunnel. Radiation Protection Dosimetry. 2026. doi:10.1093/rpd/ncaf131

BibTeX
@article{Huang2026,
  author = {Huang, Ze-Qi and Jing, Han-Tao and Wu, Qing-Biao and Dong, Qi-Fan and Li, Zhi-Ping and Li, Lun and Vassilopoulos, Nikolaos and Zhang, Yu-Liang},
  title = {Study of the typical mixed radiation field induced by the beam loss in CSNS linac tunnel},
  journal = {Radiation Protection Dosimetry},
  year = {2026},
  doi = {10.1093/rpd/ncaf131}
}
Kostenlos starten →