Fachartikel in der Zeitschrift PLOS ONE, 2023. Verfasst von Farshid Mahmoudi und 10 weiteren Autor:innen. Beteiligte Einrichtung: Razi Herbal Medicines Research Center, School of Allied Medical Sciences, Lorestan University of Medical Sciences, Khorramabad, Iran. Hauptthemen laut MEDLINE: Photons, Radiation Protection. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Tehran University of Medical Sciences and Health Services.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Neutron contamination in radiation therapy is of concern in treatment with high-energy photons (> 10 MV). With the development of new radiotherapy modalities such as spatially fractionated grid radiation therapy (SFGRT) or briefly grid radiotherapy, more studies are required to evaluate the risks associated with neutron contamination. In 15 MV SFGRT, high-Z materials such as lead and cerrobend are used as the block on the tray of linear accelerator (linac) which can probably increase the photoneutron production. On the other hand, the high-dose fractions (10–20 Gy) used in SFGRT can induce high neutron contamination. The current study was devoted to addressing these concerns via compression of neutron fluence (Φ n ) and ambient dose equivalent ( H n * ( 10 ) ) at the patient table and inside the maze between SFGRT and conventional fractionated radiation therapy (CFRT). The main components of the 15 MV Siemens Primus equipped with different grids and located inside a typical radiotherapy bunker were simulated by the MCNPX ® Monte Carlo code. Evidence showed that the material used for grid construction does not significantly increase neutron contamination inside the maze. However, at the end of the maze, neutron contamination in SFGRT is significantly higher than in CFRT. In this regard, a delay time of 15 minutes after SFGRT is recommended for all radiotherapy staff before entering the maze. It can be also concluded that H n * ( 10 ) at the patient table is at least 10 times more pronounced than inside the maze. Therefore, the patient is more at risk of neutrons compared to the staff. The H n * ( 10 ) at the isocenter in SFGRT with grids made of lead and cerrobend was nearly equal to CFRT. Nevertheless, it was dramatically lower than in CFRT by 30% if the brass grid is used. Accordingly, SFGRT with the brass grid is recommended, from radiation protection aspects.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

PhotonsRadiation ProtectionHumansParticle AcceleratorsNeutronsMonte Carlo MethodRadiation DosageCopperZinc

Substanzen

brassCopperZinc

Autor:innen und Institutionen

  • Razi Herbal Medicines Research Center, School of Allied Medical Sciences, Lorestan University of Medical Sciences, Khorramabad, Iran.
  • Department of Physics, Faculty of Science, Sahand University of Technology, Tabriz, Iran.
  • Neuroimaging and Analysis Group, Tehran University of Medical Sciences, Tehran, Iran.
  • School of Paramedicine, Bushehr University of Medical Sciences, Bushehr, Iran.
  • Department of Nuclear Engineering, Faculty of Physics, University of Isfahan, Isfahan, Iran.
  • Department of Medical Physics, School of Medicine, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran.

ORCID-Profile: Hector Rene Vega-Carrillo, Ghazale Geraily, Amir Hossein Karimi

Förderung

  • Tehran University of Medical Sciences and Health Services

Zitieren

APA

Mahmoudi, F., Mohammadi, N., Haghighi, M., Alirezaei, Z., Jabbari, I., Chegeni, N., Elmtalab, S., Vega-Carrillo, H. R., Kazemian, A., Geraily, G., & Karimi, A. H. (2023). How much should you worry about contaminant neutrons in spatially fractionated grid radiation therapy?. PLOS ONE. https://doi.org/10.1371/journal.pone.0280433

Vancouver

Mahmoudi F, Mohammadi N, Haghighi M, Alirezaei Z, Jabbari I, Chegeni N, et al. How much should you worry about contaminant neutrons in spatially fractionated grid radiation therapy?. PLOS ONE. 2023. doi:10.1371/journal.pone.0280433

BibTeX
@article{Mahmoudi2023,
  author = {Mahmoudi, Farshid and Mohammadi, Najmeh and Haghighi, Meysam and Alirezaei, Zahra and Jabbari, Iraj and Chegeni, Nahid and Elmtalab, Soheil and Vega-Carrillo, Hector Rene and Kazemian, Ali and Geraily, Ghazale and Karimi, Amir Hossein},
  title = {How much should you worry about contaminant neutrons in spatially fractionated grid radiation therapy?},
  journal = {PLOS ONE},
  year = {2023},
  doi = {10.1371/journal.pone.0280433}
}
Kostenlos starten →