EUVIMEDEUVIMED entdecken
Crossref

Response of current dosemeters to new operational quantities in rotational geometry

Zina Čemusová iD, Daniela Ekendahl iD, Dana Kurková, Libor Judas, Michaela Kapuciánová, Zdeněk Vykydal

Radiation Protection Dosimetry · 2023

DOI: 10.1093/rpd/ncac281 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Radiation Protection Dosimetry, 2023. Verfasst von Zina Čemusová und 5 weiteren Autor:innen. Beteiligte Einrichtung: Čemusová, Ekendahl, Kapuciánová- Dosimetry Department, Kurková, Judas-Gamma and X-ray Dosimetry Laboratory, National Radiation Protection Institute, …. Hauptthemen laut MEDLINE: Radiation Monitoring, Radiation Protection, Radiation Exposure. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 15 Literaturangaben. Gefördert von: Ministry of the Interior of the Czech Republic.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Recently, the ICRU released Report 95, where new operational quantities for external radiation exposure are defined. The new quantities are defined in close relation to the protection quantities. This change affects the practice use of dosemeters. That is why the instruments must be adapted to the measurement of new quantities before their implementing as legally binding. The discrepancies depend on radiation spectra-particle type, energy of particles and direction of incidence. To analyse the performance of currently used instruments, irradiations in photon and neutron fields of various energies were performed for personal and area dosemeters. In this work, the response of photon and neutron personal dosemeters in conditions of rotational geometry is presented. The difference between the responses with respect to the new or old operational quantity was not large, which corresponded to the similar reference values for this irradiation geometry. The mutual ratio depended on the specific radiation quality and geometry. The behaviour of different types of dosemeters varied too.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Radiation MonitoringRadiation ProtectionRadiation ExposureRadiation DosagePhotonsNeutrons

Autor:innen und Institutionen

  • Čemusová, Ekendahl, Kapuciánová- Dosimetry Department, Kurková, Judas-Gamma and X-ray Dosimetry Laboratory, National Radiation Protection Institute, Bartoškova 28, 14000 Prague 4, Czech Republic.

ORCID-Profile: Zina Čemusová, Daniela Ekendahl

Förderung

  • Ministry of the Interior of the Czech Republic

Zitieren

APA

Čemusová, Z., Ekendahl, D., Kurková, D., Judas, L., Kapuciánová, M., & Vykydal, Z. (2023). Response of current dosemeters to new operational quantities in rotational geometry. Radiation Protection Dosimetry. https://doi.org/10.1093/rpd/ncac281

Vancouver

Čemusová Z, Ekendahl D, Kurková D, Judas L, Kapuciánová M, Vykydal Z. Response of current dosemeters to new operational quantities in rotational geometry. Radiation Protection Dosimetry. 2023. doi:10.1093/rpd/ncac281

BibTeX
@article{emusov2023,
  author = {Čemusová, Zina and Ekendahl, Daniela and Kurková, Dana and Judas, Libor and Kapuciánová, Michaela and Vykydal, Zdeněk},
  title = {Response of current dosemeters to new operational quantities in rotational geometry},
  journal = {Radiation Protection Dosimetry},
  year = {2023},
  doi = {10.1093/rpd/ncac281}
}
Kostenlos starten →