EUVIMEDEUVIMED entdecken
Crossref

Assessment of photon and proton-induced activation in particles accelerators

Abdel-Mjid Nourreddine, Jonathan Collin, Nicolas Arbor, François Begin, Massimo Barbagallo, Federico Carminati, Giuliana Galli Carminati, Jean-Michel Horodynski

Radiation Protection Dosimetry · 2024

DOI: 10.1093/rpd/ncae146 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Radiation Protection Dosimetry, 2024. Verfasst von Abdel-Mjid Nourreddine und 7 weiteren Autor:innen. Beteiligte Einrichtung: Université de Strasbourg, IPHC, 23 rue du Loess, F-67037 Strasbourg, France. Hauptthemen laut MEDLINE: Particle Accelerators, Monte Carlo Method, Protons, Photons. Die Arbeit nennt 22 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Nuclear activation affects all operating, future, or dismantled particle accelerators used in various fields, from medical applications to industrial applications. This work is concerned with the study of the radioactivity induced in various materials (Sc, Cu, Tb, Ta, W, Au) irradiated by hard Bremsstrahlung photons from an electron beam and by secondary neutrons induced by a proton beam. In both cases, the primary beam features an 18 MeV kinetic energy. We have performed Monte Carlo simulations with MCNP, GEANT4, FLUKA, and PHITS, coupled with the analytical codes CINDER’90 or FISPACT-II, to estimate the threshold reaction rates and the induced radioactivity in the samples. We compared the simulations with experimental activation measurements performed by high-resolution gamma spectrometry at a decommissioned medical LINAC and around the CYRCé cyclotron. We also used CR-39 solid-state nuclear track detectors to characterize the thermal and fast neutron components of the secondary fields.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Particle AcceleratorsMonte Carlo MethodProtonsPhotonsNeutronsComputer SimulationSpectrometry, GammaRadiation DosageCyclotronsElectronsHumansRadiometry

Substanzen

Protons

Autor:innen und Institutionen

  • Université de Strasbourg, IPHC, 23 rue du Loess, F-67037 Strasbourg, France.
  • CEA Valduc, 21120 Is-Sur-Tille, France.
  • Transmutex SA, Chemin Blandonnet 8, CH-1214 Vernier, Switzerland.
  • Seoul National University (Bundang Hospital), 82 Gumi-ro 173beon-gil, Bundang-gu, Seongnam-si, Gyeonggi-do Seoul, Republic of Korea.
  • iRSD/CNRS, Centre Universitaire Paris-Saclay, B.P. 34, F-91898 Orsay Cedex, France.

Zitieren

APA

Nourreddine, A. M., Collin, J., Arbor, N., Begin, F., Barbagallo, M., Carminati, F., Galli Carminati, G., & Horodynski, J. M. (2024). Assessment of photon and proton-induced activation in particles accelerators. Radiation Protection Dosimetry. https://doi.org/10.1093/rpd/ncae146

Vancouver

Nourreddine AM, Collin J, Arbor N, Begin F, Barbagallo M, Carminati F, et al. Assessment of photon and proton-induced activation in particles accelerators. Radiation Protection Dosimetry. 2024. doi:10.1093/rpd/ncae146

BibTeX
@article{Nourreddine2024,
  author = {Nourreddine, Abdel-Mjid and Collin, Jonathan and Arbor, Nicolas and Begin, François and Barbagallo, Massimo and Carminati, Federico and Galli Carminati, Giuliana and Horodynski, Jean-Michel},
  title = {Assessment of photon and proton-induced activation in particles accelerators},
  journal = {Radiation Protection Dosimetry},
  year = {2024},
  doi = {10.1093/rpd/ncae146}
}
Kostenlos starten →