EUVIMEDEUVIMED entdecken
Crossref

Simulating the head of a TrueBeam linear particle accelerator and calculating the photoneutron spectrum on the central axis of a 10-MV photon using particle and heavy-ion transport system code

Soai Dang Quoc iD, Toshioh Fujibuchi iD, Hiroyuki Arakawa, Keisuke Hamada

Radiation Protection Dosimetry · 2024

DOI: 10.1093/rpd/ncae124 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Radiation Protection Dosimetry, 2024. Verfasst von Soai Dang Quoc und 3 weiteren Autor:innen. Beteiligte Einrichtung: Division of Medical Quantum Science, Department of Health Sciences, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-k…. Hauptthemen laut MEDLINE: Photons, Particle Accelerators, Monte Carlo Method, Neutrons. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 55 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Photon energy is higher than the (γ,n) threshold, allowing it to interact with the nuclei of materials with high z properties and liberate fast neutrons. This represents a potentially harmful source of radiation for humans and the environment. This study validated the Monte Carlo simulation, using the particle and heavy-ion transport code system (PHITS) on a TrueBeam 10-MV linear particle accelerator’s head shielding model and then used this PHITS code to simulate a photo-neutron spectrum for the transport of the beam. The results showed that, when comparing the simulated to measured PDD and crosslines, 100% of the γ-indexes were <1 (γ3%/3mm) for both simulations, for both phase-space data source and a mono energy source. Neutron spectra were recorded in all parts of the TrueBeam’s head, as well as photon neutron spectra at three points on the beamline.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

PhotonsParticle AcceleratorsMonte Carlo MethodNeutronsComputer SimulationHumansRadiation ProtectionHeavy IonsRadiation DosageHeadRadiometry

Autor:innen und Institutionen

  • Division of Medical Quantum Science, Department of Health Sciences, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka 812-8582, Japan.
  • Division of Medical Quantum Science, Department of Health Sciences, Faculty of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka, Fukuoka 812-8582, Japan.
  • Department of Radiological Technology, National Hospital Organization Kyushu Cancer Center, 3-1-1 Notame Minami-ku, Fukuoka, Fukuoka 811-1395, Japan.

ORCID-Profile: Soai Dang Quoc, Toshioh Fujibuchi

Zitieren

APA

Quoc, S. D., Fujibuchi, T., Arakawa, H., & Hamada, K. (2024). Simulating the head of a TrueBeam linear particle accelerator and calculating the photoneutron spectrum on the central axis of a 10-MV photon using particle and heavy-ion transport system code. Radiation Protection Dosimetry. https://doi.org/10.1093/rpd/ncae124

Vancouver

Quoc SD, Fujibuchi T, Arakawa H, Hamada K. Simulating the head of a TrueBeam linear particle accelerator and calculating the photoneutron spectrum on the central axis of a 10-MV photon using particle and heavy-ion transport system code. Radiation Protection Dosimetry. 2024. doi:10.1093/rpd/ncae124

BibTeX
@article{Quoc2024,
  author = {Quoc, Soai Dang and Fujibuchi, Toshioh and Arakawa, Hiroyuki and Hamada, Keisuke},
  title = {Simulating the head of a TrueBeam linear particle accelerator and calculating the photoneutron spectrum on the central axis of a 10-MV photon using particle and heavy-ion transport system code},
  journal = {Radiation Protection Dosimetry},
  year = {2024},
  doi = {10.1093/rpd/ncae124}
}
Kostenlos starten →