Inter-institutional variability in CT-to-mass-density conversion tables for helical tomotherapy: a national survey in Japan
Journal of Radiation Research · 2025
DOI: 10.1093/jrr/rraf063 ↗Kurz gefasst
Multizentrische Studie in der Zeitschrift Journal of Radiation Research, 2025. Verfasst von Shogo Tsunemine und 13 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation and Proton Office, Shizuoka Cancer Center, 1007 Shimonagakubo, Nagaizumi-cho, Sunto-gun, Shizuoka 411-8777, Japan. Hauptthemen laut MEDLINE: Tomography, X-Ray Computed, Radiotherapy, Intensity-Modulated, Radiotherapy Dosage, Radiotherapy Planning, Computer-Assisted. Die Arbeit nennt 23 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
This study evaluates current practices and challenges associated with computed tomography number-to-mass density (CT–MD) conversion tables in helical tomotherapy across Japan and explores directions for standardization and quality improvement amid the increasing adoption of adaptive radiotherapy (ART). A nationwide web-based survey was conducted across 34 institutions utilizing the Radixact system. Data were collected on CT acquisition protocols, calibration phantoms, density plugs, reconstruction algorithms, table registration timing and quality assurance (QA) frequency. Registered CT–MD tables were categorized by CT modality: Simulation CT (SimCT), ClearRT and CTrue. ClearRT tables were analyzed by phantom setup (full vs half), and CTrue tables by reconstruction method [filtered back projection (FPB) vs iterative reconstruction (IR)]. Inter-institutional variations in CT numbers and the number of data points were assessed. SimCT tables exhibited the widest variation in the number of data points (median = 10) and high-density CT numbers. ClearRT tables (median = 8) showed variations of up to 300 Hounsfield units (HU) in cortical bone; the half-phantom setup reduced inter-institutional variability. CTrue tables (median = 8) demonstrated high consistency, with negligible differences between IR and FPB. All plug CT numbers of CTrue remained within the tolerance defined by the American Association of Physicists in Medicine Task Group 148. However, CT numbers for air plugs varied by ~±30 HU, indicating inconsistent handling of air reference values. Additionally, 43% of institutions did not perform routine QA. Standardizing phantom geometry, air CT number handling and QA protocols—particularly using half-phantom calibration—may improve CT–MD table consistency and dose accuracy in ART.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiation and Proton Office, Shizuoka Cancer Center, 1007 Shimonagakubo, Nagaizumi-cho, Sunto-gun, Shizuoka 411-8777, Japan.
- Hiroshima High-Precision Radiotherapy Cancer Center, 3-2-2 Futabanosato, Higashi-ku, Hiroshima 732-0057, Japan.
- Division of Medical Physics, Iwata City Hospital, 512-3 Okubo, Iwata, Shizuoka 438-0002, Japan.
- Department of Radiation Oncology, Department of Radiology, Metropolitan Cancer and Infectious Disease Center Komagome Hospital, Tokyo, 3-18-22 Honkomagome, Bunkyo-ku, Tokyo 113-8677, Japan.
- Division of Medical Physics, School of Medical Sciences, Fujita Health University, 1-98 Dengakugakubo, Kutsukake-cho, Toyoake, Aichi 470-1192, Japan.
- Department of Medical Physics and Engineering, Division of Health Sciences, The University of Osaka Graduate School of Medicine, 2-15 Yamadaoka, Suita, Osaka 565-0871, Japan.
ORCID-Profile: Shogo Tsunemine, Shuichi Ozawa, Hidetoshi Shimizu, Hideyuki Harada
Zitieren
APA
Tsunemine, S., Ozawa, S., Nakada, R., Shiota, Y., Kito, S., Shimizu, H., Hashido, T., Shiinoki, T., Kitagawa, Y., Fukuma, H., Sugi, K., Sumida, I., Numano, M., & Harada, H. (2025). Inter-institutional variability in CT-to-mass-density conversion tables for helical tomotherapy: a national survey in Japan. Journal of Radiation Research. https://doi.org/10.1093/jrr/rraf063
Vancouver
Tsunemine S, Ozawa S, Nakada R, Shiota Y, Kito S, Shimizu H, et al. Inter-institutional variability in CT-to-mass-density conversion tables for helical tomotherapy: a national survey in Japan. Journal of Radiation Research. 2025. doi:10.1093/jrr/rraf063
BibTeX
@article{Tsunemine2025,
author = {Tsunemine, Shogo and Ozawa, Shuichi and Nakada, Ryosei and Shiota, Yasuo and Kito, Satoshi and Shimizu, Hidetoshi and Hashido, Takashi and Shiinoki, Takehiro and Kitagawa, Yuto and Fukuma, Hiroshi and Sugi, Kentarou and Sumida, Iori and Numano, Masumi and Harada, Hideyuki},
title = {Inter-institutional variability in CT-to-mass-density conversion tables for helical tomotherapy: a national survey in Japan},
journal = {Journal of Radiation Research},
year = {2025},
doi = {10.1093/jrr/rraf063}
}
EUVIMED