Fuzzy logic-based modeling and multi-objective optimization of blood pump rotational speed considering hydraulic and hemolytic performance
Medical Engineering & Physics · 02.11.2026 · 147 (11) · 115007
DOI: 10.1088/1873-4030/aeb4bb ↗Kurz gefasst
Fachartikel in der Zeitschrift Medical Engineering & Physics, online erschienen am 02.11.2026. Verfasst von Abdoulaye Billo Diallo und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Mechanical Engineering, Faculty of Engineering and Natural Science, Konya Technical University, Konya 42250, Türkiye. Hauptthemen laut MEDLINE: Fuzzy Logic, Hydrodynamics, Hemolysis, Heart-Assist Devices. Die Arbeit nennt 45 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
This study aims to determine the optimal operating rotational speed of a centrifugal blood pump. In order to investigate this, a centrifugal blood pump was designed, and its hydraulic efficiency and hemolysis index (HI) were calculated using computational fluid dynamics (CFD) simulations over a range of 2500-3500 rpm for rotational speed and 2.5-6 l min-1for flow rate. The pump design was carried out by considering key geometric parameters, including the number of blades, inlet and outlet widths, inlet and outlet angles, impeller diameter, volute inlet width, and volute outlet diameter. Subsequently, a fuzzy logic-based pump model was developed using rotational speed and mass flow rate as input parameters, and pressure difference, HI, and hydraulic efficiency as output parameters. After validating this model with CFD simulations, the optimal pump rotational speed was determined by solving an objective function incorporating hydraulic efficiency and HI using the particle swarm optimization (PSO) algorithm. The results indicate that the optimal rotational speed of the centrifugal pump is 3150 rpm, at which a hydraulic efficiency of 36% and a HI of 1.65 × 10-5are achieved. In summary, this study presents a systematic methodology for determining the optimal operating speed that enables centrifugal blood pumps to operate efficiently while maintaining a low HI.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Mechanical Engineering, Faculty of Engineering and Natural Science, Konya Technical University, Konya 42250, Türkiye.
- Department of Aeronautical Engineering, Faculty of Aviation and Space Sciences, Necmettin Erbakan University, Konya 42140, Türkiye.
ORCID-Profile: Abdoulaye Billo Diallo, Hasan Çınar, Ömer İncebay, Rafet Yapıcı
Zitieren
APA
Diallo, A. B., Çınar, H., İncebay, Ö., & Yapıcı, R. (2026). Fuzzy logic-based modeling and multi-objective optimization of blood pump rotational speed considering hydraulic and hemolytic performance. Medical Engineering & Physics, 147(11), 115007. https://doi.org/10.1088/1873-4030/aeb4bb
Vancouver
Diallo AB, Çınar H, İncebay Ö, Yapıcı R. Fuzzy logic-based modeling and multi-objective optimization of blood pump rotational speed considering hydraulic and hemolytic performance. Medical Engineering & Physics. 2026;147(11):115007. doi:10.1088/1873-4030/aeb4bb
BibTeX
@article{Diallo2026,
author = {Diallo, Abdoulaye Billo and Çınar, Hasan and İncebay, Ömer and Yapıcı, Rafet},
title = {Fuzzy logic-based modeling and multi-objective optimization of blood pump rotational speed considering hydraulic and hemolytic performance},
journal = {Medical Engineering & Physics},
year = {2026},
volume = {147},
number = {11},
pages = {115007},
doi = {10.1088/1873-4030/aeb4bb}
}
EUVIMED