Axial-flow polymer bridge pump with hydrodynamic bearings
Journal of Artificial Organs · 2025
DOI: 10.1007/s10047-024-01465-9 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Artificial Organs, 2025. Verfasst von Takashi Yamane und 4 weiteren Autor:innen. Beteiligte Einrichtung: School of Medicine, Kobe University, 7-5-1 Kusunokicho, Chuo-ku, Kobe, 650-0017, Japan. yamanetks53@gmail.com. Hauptthemen laut MEDLINE: Heart-Assist Devices, Polymers. Die Arbeit nennt 10 Literaturangaben. Gefördert von: Hyogo Science and Technology Association.
Abstract (Originalsprache)
A portable axial-flow polymer bridge pump with hydrodynamic bearings has been developed for bridge-to-bridge use. The pump is inexpensive to manufacture and disposable. It weighs 185 g and was verified to have a lifetime of 3 months with silent operation. For partial circulatory assist at a flow rate of 2 L/min, the clinical limit of hemolysis was verified for a rotational speed below 9000 rpm, at which a pressure of 100 mmHg was generated. In an anti-thrombogenic test, the pump stably operated for 6 h without thrombus formation.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- School of Medicine, Kobe University, 7-5-1 Kusunokicho, Chuo-ku, Kobe, 650-0017, Japan. yamanetks53@gmail.com.
- School of Engineering, Kobe University, Kobe, 657-8501, Japan.
- Yasojima Proceed Co. Ltd., Kobe, 650-0047, Japan.
- School of Medicine, Kobe University, 7-5-1 Kusunokicho, Chuo-ku, Kobe, 650-0017, Japan.
- Hyogo Prefectural Harima-Himeji General Medical Center, Himeji, 670-8560, Japan.
Förderung
- Hyogo Science and Technology Association
Zitieren
APA
Yamane, T., Akao, E., Kashiwazaki, T., Koda, Y., & Tanaka, H. (2025). Axial-flow polymer bridge pump with hydrodynamic bearings. Journal of Artificial Organs. https://doi.org/10.1007/s10047-024-01465-9
Vancouver
Yamane T, Akao E, Kashiwazaki T, Koda Y, Tanaka H. Axial-flow polymer bridge pump with hydrodynamic bearings. Journal of Artificial Organs. 2025. doi:10.1007/s10047-024-01465-9
BibTeX
@article{Yamane2025,
author = {Yamane, Takashi and Akao, Eiru and Kashiwazaki, Toshinori and Koda, Yojiro and Tanaka, Hiroshi},
title = {Axial-flow polymer bridge pump with hydrodynamic bearings},
journal = {Journal of Artificial Organs},
year = {2025},
doi = {10.1007/s10047-024-01465-9}
}
EUVIMED