Fachartikel in der Zeitschrift Physics in Medicine & Biology, online erschienen am 06.08.2026. Verfasst von Aishah Bashiri und 59 weiteren Autor:innen. Beteiligte Einrichtung: Centre for Medical Radiation Physics, University of Wollongong, Northfields Ave, Wollongong, NSW 2522, Australia. Hauptthemen laut MEDLINE: Silicon, Radiometry, Skin, Hydrogen. Die Arbeit nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Acute skin toxicity after radiation treatments highlights the need for improved dose monitoring and measurement, as the treatment planning system does not accurately estimate skin dose. Wearable radiation detectors may be the solution for most in vivo dosimetry needs, but they require innovative materials. The purpose of this work is to overcome the challenges that limit accurate skin dosimetry by exploring the use of hydrogenated amorphous silicon (a-Si:H) fabricated on a flexible polyimide substrate for direct radiation detection. The a-Si:H detector was fabricated on a 125 μ m polyimide substrate with a thickness of 3.6–10 μ m. The detector’s response to the build-up region of the percentage depth dose (PDD) of the MV photon beam was compared to Geant4 radiation transport simulations and benchmarked to Attix ionization chamber measurements. Angular dependency and surface field factors at the phantom surface were compared to Attix IC. The PDD measurement is within 2% of Geant4’s simulation and the Attix chamber’s response from 150 μ m to 25 mm in a plastic water phantom. All samples showed linear dose responses with 0.37% reproducibility. The a-Si:H device matches the Attix chamber for surface field factor measurements (6–10 MV photon beams, for 5 to 25 cm field sizes). The angular dependence (−60° to +60°) compared to the Attix IC confirms the sensor’s WED of 150 ± 5 µ m. This study demonstrates that a-Si:H sensors on flexible plastic substrates have a potential for accurate surface dose measurements and agree with reference detectors. This thin, flexible detector provides real time measurements and is stable under high radiation doses. The possibility to assemble with ease an array of a-Si:H pixels over large areas with different sizes and shapes, makes this technology attractive for in vivo dosimetry.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

SiliconRadiometrySkinHydrogenRadiotherapy, High-EnergyPhantoms, ImagingRadiotherapy Dosage

Stichwörter der Autor:innen

amorphous siliconin vivo dosimetryradiation detectorradiotherapyskin dose

Substanzen

SiliconHydrogen

Autor:innen und Institutionen

  • Centre for Medical Radiation Physics, University of Wollongong, Northfields Ave, Wollongong, NSW 2522, Australia.
  • Department of Physics, Faculty of Arts and Sciences Najran University, King Abdulaziz Rd, Najran 1988, Saudi Arabia.
  • Shoalhaven Cancer Care Centre, Nowra, NSW 2541, Australia.
  • INFN Sezione di Lecce, via per Arnesano, 73100 Lecce, Italy.
  • Department of Mathematics and Physics 'Ennio de Giorgi' University of Salento, Via per Arnesano, 73100 Lecce, Italy.
  • INFN Sez. di Torino Via Pietro Giuria, 1, 10125 Torino, Italy.

ORCID-Profile: Aishah Bashiri, Shane Pavitt, Rabia Sandhu, Massimo Cazzanelli, Michele Fabi, Luca Frontini, Catia Grimani, Hamza Hasnaoui, Giacomo Insero, Valentino Liberali, Loris Barraud, Giuseppe Maruccio, Giovanni Mazza, Stefania Pallotta, Maddalena Pedio, Silvia Rizzato, Cinzia Talamonti, Alberto Verdini

Zitieren

APA

Bashiri, A., Anderson, C., Posar, J., Pavitt, S., Dookie, Y., McNamara, J., Sandhu, R., Aziz, S., Calcagnile, L., Calvo, D., Caputo, D., Caricato, A. P., Catalano, R., Cazzanelli, M., Cirio, R., Cirrone, G. A. P., Cittadini, F., Croci, T., Cuttone, G., …, & Verdini, A. (2026). Skin dosimetry in megavoltage radiotherapy using hydrogenated amorphous silicon on a tissue-equivalent flexible substrate. Physics in Medicine & Biology, 71(15), 155020. https://doi.org/10.1088/1361-6560/ae8ef6

Vancouver

Bashiri A, Anderson C, Posar J, Pavitt S, Dookie Y, McNamara J, et al. Skin dosimetry in megavoltage radiotherapy using hydrogenated amorphous silicon on a tissue-equivalent flexible substrate. Physics in Medicine & Biology. 2026;71(15):155020. doi:10.1088/1361-6560/ae8ef6

BibTeX
@article{Bashiri2026,
  author = {Bashiri, Aishah and Anderson, Cameron and Posar, Jessie and Pavitt, Shane and Dookie, Yashiv and McNamara, Joanne and Sandhu, Rabia and Aziz, Saba and Calcagnile, Lucio and Calvo, Daniela and Caputo, Domenico and Caricato, Anna Paola and Catalano, Roberto and Cazzanelli, Massimo and Cirio, Roberto and Cirrone, Giuseppe Antonio Pablo and Cittadini, Federico and Croci, Tommaso and Cuttone, Giacomo and de Cesare, Gianpiero and de Remigis, Paolo and Dunand, Sylvain and Fabi, Michele and Frontini, Luca and Grimani, Catia and Guarrera, Mariacristina and Hasnaoui, Hamza and Insero, Giacomo and Ionica, Maria and Kanxheri, Keida and Konstantinou, Georgios and Lenta, Francesca and Liberali, Valentino and Barraud, Loris and Lovecchio, Nicola and Ponzecchi, Marta and Maruccio, Giuseppe and Martino, Maurizio and Mazza, Giovanni and Menichelli, Mauro and Monteduro, Anna Grazia and Morozzi, Arianna and Nascetti, Augusto and Pallotta, Stefania and Passeri, Daniele and Pedio, Maddalena and Petringa, Giada and Peverini, Francesca and Placidi, Pisana and Polo, Matteo and Quaranta, Alberto and Quarta, Gianluca and Rizzato, Silvia and Sabbatini, Federico and Servoli, Leonello and Stabile, Alberto and Talamonti, Cinzia and Tosti, Luca and Mora, Monica Setia Vasquez and Verdini, Alberto},
  title = {Skin dosimetry in megavoltage radiotherapy using hydrogenated amorphous silicon on a tissue-equivalent flexible substrate},
  journal = {Physics in Medicine & Biology},
  year = {2026},
  volume = {71},
  number = {15},
  pages = {155020},
  doi = {10.1088/1361-6560/ae8ef6}
}
Kostenlos starten →