Clinical evaluation of two new unshielded and shielded silicon diode detectors in external photon beam radiation therapy: SunSILICON and SunSILICON P
Journal of Applied Clinical Medical Physics · 2026-04 · 27 (4)
DOI: 10.1002/acm2.70576 ↗Kurz gefasst
Evaluationsstudie in der Zeitschrift Journal of Applied Clinical Medical Physics, online erschienen am 19.04.2026. Verfasst von Teresa J Anders und 13 weiteren Autor:innen. Beteiligte Einrichtung: Radiologie Vechta, Vechta, Germany. Hauptthemen laut MEDLINE: Photons, Silicon, Radiometry, Particle Accelerators. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 40 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background
Advanced external photon beam radiotherapy requires dosimetry detectors with high spatial resolution and minimal perturbation effects. Silicon diode detectors are widely used due to their high sensitivity and small sensitive volumes, but fluence perturbation effects and energy dependence can affect performance and depend on detector construction. Shielded and unshielded configurations are used to address these challenges, but their clinical performance and limitations require systematic evaluation.
Purpose
This study aims to evaluate the clinical performance of two newly developed silicon diode detectors—SunSILICON (unshielded) and SunSILICON P (shielded)—for relative dosimetry in external photon beam radiotherapy. The detectors’ response behaviors are compared to established detectors across the full clinical range of field sizes and beam energies, focusing on percentage depth dose (PDD) and lateral beam profile measurements.
Methods
PDD and lateral beam profile measurements across the full range of clinical field sizes were performed on Varian TrueBeam and Elekta Versa HD clinical linear accelerators with photon energies ranging from 4 to 25 MV, as well as a Nordion Eldorado 6 60 Co unit, using various types of motorized water phantoms. Comparative measurements were performed with ionization chambers, as well as other silicon and diamond detectors. Over 600 scans were analyzed, and gamma analysis was applied to assess agreement using 0.5%/0.5 mm for PDDs and 1%/1 mm for lateral beam profiles. Angular dependence, detector sensitivity and the effective point of measurement (EPOM) were determined in solid phantoms.
Results
SunSILICON and SunSILICON P demonstrated excellent agreement with established detectors within their specified field size ranges. Gamma passing rates exceeded 99% for most comparisons, with minor deviations in large fields or at field size limits. The shielded SunSILICON P showed reduced energy dependence in large fields compared to the unshielded version, while SunSILICON showed superior performance in small fields. Both detectors exhibited minimal angular dependence (
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Radiologie Vechta, Vechta, Germany.
- Universität Bremen, Bremen, Germany.
- Sun Nuclear Corp., Melbourne, Florida, USA.
- CDT-West - Centrum für Diagnostik und Therapie, Cologne, Germany.
- Mirion Technologies, Olen, Antwerp, Belgium.
- MyMichigan Health, Midland, Michigan, USA.
ORCID-Profile: Teresa J Anders, Ndimofor Chofor, Damian Czarnecki
Zitieren
APA
Anders, T. J., Flatten, V., Alissa, M., Towle, D., Murray, A., Schönfeld, A. B., Alquist, E., Evrard, O., Hildreth, J., Chofor, N., Wessing, G., Habib, C., Czarnecki, D., & Schönfeld, A. A. (2026). Clinical evaluation of two new unshielded and shielded silicon diode detectors in external photon beam radiation therapy: SunSILICON and SunSILICON P. Journal of Applied Clinical Medical Physics, 27(4). https://doi.org/10.1002/acm2.70576
Vancouver
Anders TJ, Flatten V, Alissa M, Towle D, Murray A, Schönfeld AB, et al. Clinical evaluation of two new unshielded and shielded silicon diode detectors in external photon beam radiation therapy: SunSILICON and SunSILICON P. Journal of Applied Clinical Medical Physics. 2026;27(4). doi:10.1002/acm2.70576
BibTeX
@article{Anders2026,
author = {Anders, Teresa J and Flatten, Veronika and Alissa, Mohamad and Towle, David and Murray, Andy and Schönfeld, Ann-Britt and Alquist, Erik and Evrard, Olivier and Hildreth, Jeff and Chofor, Ndimofor and Wessing, Gerhard and Habib, Charbel and Czarnecki, Damian and Schönfeld, Andreas A},
title = {Clinical evaluation of two new unshielded and shielded silicon diode detectors in external photon beam radiation therapy: SunSILICON and SunSILICON P},
journal = {Journal of Applied Clinical Medical Physics},
year = {2026},
volume = {27},
number = {4},
doi = {10.1002/acm2.70576}
}
EUVIMED