Influence of scintillation light confinement on depth-of-interaction measurement performance in a single-ended readout PET detector
Physics in Medicine & Biology · 28.05.2026 · 71 (10) · 105024
DOI: 10.1088/1361-6560/ae6ead ↗Kurz gefasst
Fachartikel in der Zeitschrift Physics in Medicine & Biology, online erschienen am 01.06.2026. Verfasst von Hyeong Seok Shim und 5 weiteren Autor:innen. Beteiligte Einrichtung: Interdisciplinary Program in Bioengineering, College of Engineering, Seoul National University, Seoul, Republic of Korea. Hauptthemen laut MEDLINE: Positron-Emission Tomography, Light, Scintillation Counting. Die Arbeit nennt 33 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Research Foundation of Korea, Korea Brain Research Institute, Korea Health Industry Development Institute.
Abstract (Originalsprache)
Continuous depth-of-interaction (cDOI) detectors enable single-ended readout in positron emission tomography (PET) by encoding the interaction depth into the scintillation light distribution. This study presents a comprehensive performance optimization of a cDOI detector based on light distribution tailoring with crossed triangular-shaped reflectors by analyzing the effects of optical geometry based on various DOI decoding algorithms. Two parameters were systematically varied: the degree of light confinement through (1) optical segmentation and (2) crystal pitch adjustment. Five DOI decoding strategies—variance, max/sum ratio, Euclidean-distance classification, Gaussian and modified maximum-likelihood estimation, and artificial neural network (ANN) decoding—were adopted with 8 × 8 SiPM readout data. Results show that moderate segmentation (2 × 2 configuration) achieved the best DOI precision, yielding a 4.7 mm full width at half maximum (FWHM) and an ANN classification accuracy of 89 %. In the pitch study, 1.5 mm-pitch detector achieved better performance than 3.0 mm-pitch, indicating that increased optical interfaces allows more accurate encoding of the depth-dependent light distribution within the SiPM array. The ANN decoder consistently outperformed in DOI resolution compared to analytical and statistical methods by learning nonlinear spatial correlations among SiPM pixels. These findings highlight the coupled importance of optical geometry and data-driven decoding for achieving high DOI sensitivity in next-generation PET detector designs.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Interdisciplinary Program in Bioengineering, College of Engineering, Seoul National University, Seoul, Republic of Korea.
- Integrated Major in Innovative Medical Science, Seoul National University, Seoul, Republic of Korea.
- Department of Nuclear Medicine, Seoul National University College of Medicine, Seoul, Republic of Korea.
- Department of Radiology, Molecular Imaging Program, Stanford University, Stanford, California, United States of America.
- Department of Electrica Engineering and Computer Science, Daegu Gyeongbuk Institute of Science and Technology, Daegu, Republic of Korea.
ORCID-Profile: Min Sun Lee, Jae Sung Lee
Förderung
- National Research Foundation of Korea
- Korea Brain Research Institute
- Korea Health Industry Development Institute
Zitieren
APA
Shim, H. S., Cho, M. J., He, W., Lee, M. S., Levin, C. S., & Lee, J. S. (2026). Influence of scintillation light confinement on depth-of-interaction measurement performance in a single-ended readout PET detector. Physics in Medicine & Biology, 71(10), 105024. https://doi.org/10.1088/1361-6560/ae6ead
Vancouver
Shim HS, Cho MJ, He W, Lee MS, Levin CS, Lee JS. Influence of scintillation light confinement on depth-of-interaction measurement performance in a single-ended readout PET detector. Physics in Medicine & Biology. 2026;71(10):105024. doi:10.1088/1361-6560/ae6ead
BibTeX
@article{Shim2026,
author = {Shim, Hyeong Seok and Cho, Min Jeong and He, Wen and Lee, Min Sun and Levin, Craig S and Lee, Jae Sung},
title = {Influence of scintillation light confinement on depth-of-interaction measurement performance in a single-ended readout PET detector},
journal = {Physics in Medicine & Biology},
year = {2026},
volume = {71},
number = {10},
pages = {105024},
doi = {10.1088/1361-6560/ae6ead}
}
EUVIMED